5. Operation
Automatic
Charging mode
Automatic
Start phase
5.6

Automatic Operation

CAUTION
Before connecting to the electrical system, make sure
the unit has been positioned properly and that the
electrical system is protected by fuses (as described
in Chapter 4.6).
As soon as you connect the unit to the battery and after
every reset the unit will start the automatic operation
mode.
The unit monitors the battery voltage and starts
charging as soon as the battery voltage drops bellow a
defined threshold. It will stop charging as soon as the
battery voltage exceeds the defined switch off
threshold.
Note: To guarantee optimal battery maintenance, it is
important that the charge current is not stopped
abruptly when the deactivation threshold is reached.
For this reason, the EFOY Pro continues to charge for
up to 3 h after the deactivation threshold set is
reached (by default, 14.2 Volt is preset). The
recharging period depends on the battery voltage and
the electricity consumption.
The thresholds for automatic charging can be modified
with a computer – see Computer interface user manual.
Please note that the device interrupts power
generation briefly several times an hour during
normal operation and a charging power of 0.0 A is
displayed then.
The second line of the display will indicate "charging
mode" as long as the unit is providing voltage to the
electrical system.
The device goes through a cold start phase of about 20
minutes before reaching its full rated output.
33