EFOY Pro 600 Manual page 21

Hide thumbs Also See for Pro 600:
Table of Contents

Advertisement

4. Installation
To minimize current loss in the leads, the following
cross section is recommended, should the battery
charging cable be insufficient:
Length [m]
min. cross section
< 5 m
2.5 mm²
5 – 10 m
4.0 mm²
10 – 15 m
6.0 mm²
Accessories:
Extension sense line 8 m (Art. No. 151 906 005)
Extension Power line 8 m (Art. No. 151 906 006)
Notes:
 The EFOY Pro is charging the connected battery and
the battery supplies the power for the application..
 The EFOY Pro can only be used to charge lead
batteries which conform to the technical
specification (see chapter 3.3, page 13).
 The EFOY Pro can charge 12 V and 24 V batteries
and automatically detects the voltage of the
connected battery.
 The charging parameters for the automatic mode
can be adjusted with a standard PC – see user
manual of computer interface adapter.
 To protect the battery against deep discharging it is
recommended to install a low-voltage load
disconnector that disconnects the load from the
battery.