Switching On Manually; Switching Off Manually - EFOY Pro 600 Manual

Hide thumbs Also See for Pro 600:
Table of Contents

Advertisement

5. Operation
Automatic
Standby
Automatic
Please change fuel cartridge
On
Charging mode
Off
Shutting down
If the battery is sufficiently charged the unit will remain
in the standby mode.
Should the device detect a malfunction such as an
empty fuel cartridge, it will shut down and advise you
how to correct the situation. ("Please change fuel
cartridge".) Resume automatic operation using the
reset button after the error has been corrected
(See Chapter 7, page 44).
5.7

Switching On manually

If desired, you can switch on the unit manually regard-
less of the battery voltage. The unit will then be in the
"charging mode".
This function is only possible when the battery voltage
is below 13.2V / 26.4 V.
Press
on the control panel once if the unit has been
switched off, and twice if it is operating in automatic
mode. The unit will start up regardless of the battery
voltage and will continue charging until it reaches the
switch-off point.
The device will then switch to automatic mode by itself
and will only charge if the battery or the demand for
power requires it.
5.8

Switching Off manually

Press
on the remote control to switch off the device.
The unit will gradually shut down, performing various
function checks as it does so:
To protect components, the unit must run at least
30 minutes before shutting down. If the unit is shut off
beforehand, it will continue running until 30 minutes
34