DESCRIPTION
The MN114 (Catalog #2110.71) is a high accuracy voltage output current probe for tight areas such
as crowded wiring. Extends DMM AC measurements to 10A AC. The Model MN114 offers a 5 ft lead
with safety 4mm banana plug.
WARNING
These safety warnings are provided to ensure the safety of personnel and proper operation of the
instrument.
• Read the instruction manual completely and follow all the safety information before attempting
to use or service this instrument.
• Use caution on any circuit: Potentially high voltages and currents may be present and may
pose a shock hazard.
• Read the Safety Specifications section prior to using the current probe. Never exceed the
maximum voltage ratings given.
• Safety is the responsibility of the operator.
• ALWAYS connect the current probe to the display device before clamping the probe onto the
sample being tested.
• ALWAYS inspect the instrument, probe, probe cable, and output terminals prior to use.
Replace any defective parts immediately.
• NEVER use the current probe on electrical conductors rated above 250V. Use extreme caution
when clamping around bare conductors or bus bars.
INTERNATIONAL ELECTRICAL SYMBOLS
This symbol signifies that the current probe is protected by double or reinforced insulation. Use
only factory specified replacement parts when servicing the instrument.
This symbol signifies CAUTION! and requests that the user refer to the user manual before
using the instrument.
This is a type A current sensor. This symbol signifies that application around and removal from
HAZARDOUS LIVE conductors is permitted.
RECEIVING YOUR SHIPMENT
Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify
your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately
with the carrier and notify your distributor at once, giving a detailed description of any damage.
INSTRUMENT COMPATIBILITY
The Model MN114 is compatible with any voltmeter, multimeter, or other voltage measuring instruments
with an input impedance greater than 100K. To achieve the stated accuracy, use the MN114 with a
voltmeter having an accuracy of 0.75% or better.

Advertisement

loading

Summary of Contents for AEMC MN114

  • Page 1 DESCRIPTION The MN114 (Catalog #2110.71) is a high accuracy voltage output current probe for tight areas such as crowded wiring. Extends DMM AC measurements to 10A AC. The Model MN114 offers a 5 ft lead with safety 4mm banana plug.
  • Page 2 =0.47" max. (12 mm) Black 0.87" 1.26" (22 mm) (32 mm)
  • Page 3: Electrical Specifications

    3kV 50/60Hz dielectric for 1mn between core and output cable Common Mode Voltage: 30V AC ORDERING INFORMATION MECHANICAL SPECIFICATIONS AC Current Probe MN114 ..Cat #2110.71 Operating Temperature: -13° to 122°F (-25° to 50°C) Accessories: Banana plug adapter Storage Temperature: (to nonrecessed plug) ....
  • Page 4 Making Measurements with the AC Current Probe Model MN114  Connect the black (S2) and red (S1) terminals to the 2 V range of your DMM or instrument. The MN114 has a ratio of 10:1. This means that for 10A AC in the conductor around which the probe is clamped, 1V AC will come out of the probe leads to your DMM or instrument.