COOPER POWER Deadbreak Apparatus Connectors SERIES Effective February 2017 MN650043EN Supersedes October 2004 (S550-12-1) 200 A 15/25 kV class deadbreak straight connector installation instructions...
Page 2
CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to...
FOR LIFE FOR LIFE Eaton’s Cooper Power series products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user’s purpose, contact your Eaton representative. installation instructions MN650043EN February 2017...
If not already in place, apply a suitable jacket seal over the jacket and exposed neutral wires. otee: If an Eaton Cooper Power series jacket seal is used, follow instructions supplied with the jacket seal kit. Proceed to Step 5.
200 A 15/25 kV class deadbreak straight connector installation instructions Step 5 Step 6 Step 7 First crimp placed below shoulder Clean and lubricate Clean excess inhibitor grease Attach ground lead to ground Clean lubricate Attach lead to system ground Clean and lubricate cable entrance Straight connector and coppertop installation...
Page 9
200 A 15/25 kV class deadbreak straight connector installation instructions This page intentionally left blank. installation instructions MN650043EN February 2017...
Page 10
200 A 15/25 kV class deadbreak straight connector installation instructions This page intentionally left blank. installation instructions MN650043EN February 2017...
Page 11
200 A 15/25 kV class deadbreak straight connector installation instructions This page intentionally left blank. installation instructions MN650043EN February 2017...
Need help?
Do you have a question about the 200 A 15 kV class and is the answer not in the manual?
Questions and answers