Over time, the operating time per charge will degrade. If the operating time is no longer acceptable, the battery must be replaced. Avoid using in heavy vibration or heavy airflow conditions. Specifications EH-SS-30 Model EH-SS-3 EH-SS-6 EH-SS-15 Max Capacity 3 kg (6.6 lb)
Function Keys Power off Power on and zero ZERO Sets parameters and input data Tare key TARE Normal Weighing Mode 1. Place the scale on a flat, stable surface. Level the scale using the leveling bubble. 2. Power on the scale by pressing the ON/ZERO key. There will be an audible tone, the firmware version will be shown, and the display will count down from 9 to 0.
Check Weighing (Data Compare) Mode The check weighing or data compare function allows the user to input a pre-set range, and the display will indicate whether the weighed value is within that range, or indicate if it is too high or too low. 1.
Counting Mode (cont’d) the first zero digit flashing. Enter the quantity of items using the SET/0~9 key to increase the flashing digit and the TARE key to accept a digit and move to the next position. After the last digit is entered, the scale calculates the piece-weight and displays the count on the scale Note: Piece quantity must be between 1 and 30,000.
Page 7
User Parameter Setup Mode 1. From normal weighing mode, press the SET/0~9 key for 3 seconds to enter Setup mode. 2. Press and release the SET/0~9 key to cycle through the parameter modes listed below. 3. To enter a parameter mode, press the TARE key. 4.
Page 8
Loadcells are not replaceable by the user. Contact the manufacturer at www.measuretek.net. EH‐SS ...