TABLE OF CONTENTS INTRODUCTION ........................ 1 1.1 General and Safety Information ........................1 1.2 Specifications ..............................1 1.3 OVERVIEW OF CONTROLS AND FUNCTIONS ................. 2 1.3.1 Display ................................. 2 1.3.2 Control Functions ............................2 OPERATIONS ........................4 2.1 Turing Scale On/Off and Weighing ........................4 2.2 Change Unit of Measures ..........................
Electronic scales are precision instruments. Do not operate near cell phones, radios, computers or other electronic devices that emit radio frequencies that may cause unstable readings. 1.2 Specifications 12R982B 12R983B 12R984B 12R985B Model EHC-C-3 EHC-C-6 EHC-C-15 EHC-C-30 Max. Capacity 6 lb (3 kg) 12 lb (6 kg) 30 lb (15 kg)
1.3 OVERVIEW OF CONTROLS AND FUNCTIONS 1.3.1 Display WEIGHT - Weight on platform Zero - Scale is zeroed, gross weight is 0, tare is 0 Tare - Display reading is net weight; tare is not 0 kg - Overall unit of measure is kg lb - Overall unit of measure is lb PIECE WEIGHT - The weight per piece used to calculate the piece quantity Print - Data output indicator...
Page 5
Button Function Turns the scale on / If scale is on, sets Turns the scale on / If scale is on, sets zero Turns the scale off Turns the scale off (Long press) Exists the Setup, Calibration or other modes Exists the Setup, Calibration or other modes Performs a tare operation Performs a tare operation...
2. OPERATIONS 2.1 Turing Scale On/Off and Weighing 1) Place the scale on a flat, stable surface. Level the scale using the leveling bubble at the lower left side of the display. 2) With the weighing platter empty, turn on power switch (located underneath on the left-hand side of the scale).
2.4Counting Use this mode to count parts of uniform weight. The indicatordetermines the quantity based on the average weight of a single part.All parts must be uniform in weight for accurate measurement. Establishing the Piece Weight (PWT) Get the PWT by weighing a sample of known quantity 1) Place a known quantity of objects onto the platter and press the PCWT/SPL key for 4 seconds to enter piece weight calculation mode.
display “ ”, the PIECE WEIGHT window will display the times of accumulation instances, and the COUNT window will display the accumulated quantity. Clear the accumulated values To clear accumulated quantities, press and hold the0/Clearkey while the accumulated values are being displayed NOTE: 1) To avoid duplicating a value for a same load, the accumulation function requires the original load to be...
NOTE: 1) Limits will be stored in memory until they are modified according to the above steps. 2) Limits should be: Upper limit ≥lower limit>0. If the upper limit is less than lower limit or if the upper limit is set as zero, check weighing is disabled. 3) To turn check weighing off, follow the above instructions and change the upper limit to zero.
Page 10
NOTE: 1) In any step of the above operations, press the ZERO/ON/OFF key to exit this mode. 2) A flow chart diagram outlining the above process is shown as below. Storing Piece Weights and Tares into Memory EHC-C www.easthigh.com.cn...
2.8 Recalling Piece Weights and Tares from Memory 1) In normal weighing mode, press the RC.PLU key to enter this mode. The WEIGHT window will display “ ” (RECALL) and the COUNT window will display “ ”. The PIECE WEIGHT window will display the input address data to be entered.
normal weighing mode and press and hold the ZERO/ON/OFFand 6keys for 3 seconds. The WEIGHT window will display “ ”, the PIECE WEIGHT window will display “ ”, and the COUNT window will display the current ID code (default is ).
stable and the unit indicator stops flashing. " " " " ! ! ! ! 8) When the PIECE WEIGHT window displays 0” again, the scale is ready to re-confirm the zero point, move away any weight on the scale, after the scale is ready and unit indicator stops flashing, press the ENTER to confirm.
Page 14
4) Connect the scale with computer via RS232 cable, then power on the scale. Open the Hyperterminal (pre-installed in PC) or COM ASSISTANT (available from the link as below) on the computer, set the baud rate and data format on the software to 9600 and 8N1, and then clickOpen Com. http://www.easthigh.com.cn/fileInfoController/index?buttonType=DOWNLOAD Data will be exported via the RS232 interface in the following format.
5. DEFINITIONS 5.1 Character Key Entry Definitions Character Character 0 space ( ) ÀÂÆÇÈÉÊË Î ÏÔÙÛÜ 1ABC 2DEF 3GHI 4JKL 5MNO 6PQRS 7TUV 8WXYZ Example: To enter “nut 8”, press the 5 key three times, pause, press the 7 key three times, pause, press the 7 key twice, pause, press the zero key once, pause, and press the 8 key once.
- Data length exceeds the LED display digits % % % % - Calibration enable switch is ON - Calibration enable switch is OFF 6. TROUBLESHOOTING 6.1 Troubleshooting Symptom Probable Cause Remedy Weight reading exceeds the overload limit or Reduce load on scale until weight value the weight value cannot be displayed in the can be displayed, or use an alternate unit current unit of measure.
Any product which is determined to be defective in material or workmanship within this time period may, as the exclusive remedy, be returned to an authorized MeasureTek distributor or service center, freight prepaid with prior return authorization, to be repaired or replaced at the manufacturer’s option.MeasureTek’s liability under this warranty is limited to the repair or replacement of the...