Digital Dream UC300 User Manual page 11

Usb motion controller for mach3
Table of Contents

Advertisement

5.5 Function Switch for MPG
As the Picture 5-1 showed, the marked No.6 is the switch for the options of two type MPG.For EC500,it
can supply both standard MPG and NV-MPG which is made by our company Digital Dream. The Marked No.
5 is the interface for the connection of MPG.
The difference connection for Standard MPG and NV-MPG is from the Pin1 and Pin 2.Pls check the
following table.Pls don't also forget when you need standard MPG turns the switch to STD,and when you
need NV-MPG,switch it to NV.Then wiring the connections of MPG interface.
MPG TYPE
PIN NO.
1
TXD
9
PIN No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Digital Dream Mach3 Motion Controller
STD(STANDARD MPG)
Mark
Definition
BIN
Select Axis B
MPG serial communication Output Port For the digital display
CIN
Select Axis C
MPG
Mark
T1OUT
TXD of Serial port
VMPG
Power supply + for MPG(5V)
WHA+
A phase positive of the encoder
WHB+
B phase negative of the encoder
XIN
X axis select input
ZIN
Z axis select input
X100IN
100 rate select input
EP
Estop port
R1IN
RXD of Serial port
GND
Ground and common end
WHA-
A phase positive of the encoder
WHB-
B phase negative of the encoder
YIN
Y axis select input
AIN
A axis select input
X10IN
10 rate select input6
NV(NVMPG)
Description
Description
Mark
T1OUT
R1IN
Definition
Page -9
Definition
OUT for serial port
IN for serial port
UC300 User's Manual

Advertisement

Table of Contents
loading

Table of Contents