Safety Rules - Wolf Steel Condo Pack Installation And Operating Instructions Manual

Thru-the-wall self contained heating & cooling unit
Table of Contents

Advertisement

3.2

SAFETY RULES

1� Use this unit only with type of gas approved for the furnace module. Refer to the unit rating plate.
2. Store this unit only in dry indoor locations (protected from weather).
3� DO NOT install this unit outdoors or in a mobile home, trailer or recreational vehicle. This appliance is not
designed/certified for these installations.
4� DO NOT install unit in a corrosive or contaminated atmosphere.
5. For lighting and shutting down the furnace refer to "Furnace Start Up and Furnace Shut Down", section 5 of
this manual.
6� Install this unit only in dry indoor locations (protected from weather).
7. Provide adequate combustion and ventilation air to the unit space as specified in section 4.9 "Venting and
Combustion Piping".
8� Combustion products must be discharged outdoors using factory installed vent system only, as specified in
section 4.9 "Venting and Combustion Piping"�
9. Never test for gas leaks with an open flame. Use a commercially available soap solution made specifically for
the detection of leaks to check all connections as specified in "Gas Supply and Piping" section of this manual.
10� Both Supply and Return Air must be ducted to the appliance from rooms separate to the enclosure housing
the appliance. Be sure that duct system has external static pressure within allowable operating range
(as listed on unit's Rating Plate). Completely seal supply and return air ducts to unit casing.
See Section 4.7 "Ductwork" for more detail.
11� RETRUN air must be ducted to the appliance from a separate room(s) within the conditioned space.
Fresh make up air must never be added directly to RETURN air duct; fresh make up air must always
be brought in via an external HRV system before adding it to the RETURN air duct.
12� Always install unit to operate within the temperature-rise range and an external static pressure range (ducting),
as listed on the unit rating plate.
13� A gas-fired unit for installation in a storage garage must be installed so that the ignition sources, including
blowers and contactors (See page 16, "IMPORTANT", 1a.), are no less than 18" (457 mm) above the floor.
The unit must be located, or protected to avoid physical damage by vehicles. See safety warnings.
14� Return air temperature range that must be maintained is:
between 55°F (13°C) and 80°F (27°C) for gas heat and
between 65°F (18°C) and 90°F (32°C) for air conditioning.
15. The furnace must be kept free and clear of insulating material. Carefully examine the furnace area when the
furnace is installed or/when insulation is added. Insulating material may be combustible.
16. DO NOT USE FOR HEATING AND COOLING BUILDINGS OR STRUCTURES UNDER CONSTRUCTION!
Units that are damaged or entrained with construction debris will not be covered under warranty.
17. Before installing unit, make sure you know all applicable codes. National, state and local codes may take
precedence over any instructions in this manual. Be sure to consult:
Authorities having jurisdiction over HVAC system installations;
Local code authorities for information on electrical wiring.
WHEN THIS UNIT IS INSTALLED IN A STORAGE GARAGE, IT MUST BE INSTALLED SO
THE BURNERS AND IGNITION SOURCE ARE LOCATED NO LESS THAN 18" (457 mm)
ABOVE THE FLOOR TO PREVENT THE RISK OF IGNITING FLAMMABLE VAPORS WHICH
THE FURNACE MUST BE LOCATED OR PROTECTED TO AVOID PHYSICAL DAMAGE BY
FAILURE TO HEED THESE WARNINGS CAN CAUSE A FIRE OR EXPLOSION, RESULTING
IN PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
WARNING
!
MAY BE PRESENT IN THE GARAGE.
VEHICLES.
!
H3.6.1
W415-1307 / B / 03.31.2017
7
IOM