Model Nomenclature; Overview - Wolf Steel Condo Pack Installation And Operating Instructions Manual

Thru-the-wall self contained heating & cooling unit
Table of Contents

Advertisement

1. MODEL NOMENCLATURE

P
BRAND
P=Condo Pack
S=Single Packaged Vertical
R=Roof Top
P=Packaged Residential
C - Gas Condensing
S - Gas Standard
E - Electrical
H - Hydronic
D - Duct only (No heat)
i.e. PSD000A012A
G a s C o n d e n s i n g
Heat designation
000 - Duct Only
015 - 15 000 Btu/h
030 - 30 000 Btu/h
040 - 40 000 Btu/h
050 - 50 000 Btu/h
E l e c t r i c H eat
Heat designation
000 - Duct Only
005 - 5.0 kW
007 - 7.5 kW
010 - 10 kW
015 - 15 kW

2. OVERVIEW

These instructions cover the installation of the Condo Pack, which consists of four separate sections:
the wall sleeve, the cabinet, the air conditioning (AC) and the furnace modules. Instead of replacing the
complete system, the AC and furnace modules can be partially or fully removed for servicing. All control
harnesses are separated with modular quick disconnects, so module replacements do not require rewiring.
Both modules have been factory run-tested and ready for easy installation as a complete package. This
unit, equipped with a high efficiency furnace module, is certified as a Category IV direct vent central forced
air furnace�
These instructions are intended as an aid to the licensed service technician. Improper installation
may damage equipment, void the warranty, and can create a hazard, resulting in injury or death. Our
HVAC systems and components are designed to be installed by qualified HVAC technicians ONLY. The
installation of HVAC systems includes electrical, gas, and refrigerant connections and is regulated by
a multiple set of laws, codes and guidelines, at the federal, state and local levels. It is the installer's
responsibility to install the product in accordance with all applicable codes and regulations. It is the home
owner's responsibility to properly maintain the equipment. NO WARRANTY is offered for the products
that were installed by unlicensed/unauthorized persons. Failure to comply with this policy could lead to
violations of applicable laws that are punishable. Documentation and specifications are continuously
updated and subject to change. Please download the latest version of specifications and manuals at http://
www.napoleonheatingandcooling.com.
S
C
040
HEAT
MODEL
TYPE
CAPACITY
Gas Standard(80%)
Heat designation
000 - Duct Only
026 - 26 000 Btu/h
038 - 38 000 Btu/h
051 - 51 000 Btu/h
064 - 64 000 Btu/h
H yd ro n i c H e at
Heat designation
000 - Duct Only
030 - 30 000 Btu/h
042 - 42 000 Btu/h
A
HEAT
COOLING
TYPE
Air Conditioning
000 - Blower Only
012 - 12 000 Btu/h / 1.0 Ton
018 - 18 000 Btu/h / 1.5 Ton
024 - 24 000 Btu/h / 2.0 Ton
030 - 30 000 Btu/h / 2.5 Ton
A - Air Conditioning - std. eff. Rev A
B - Air Conditioning - std. eff. Rev B
C - Air Conditioning - high eff.
H - Heat Pump - std. eff.
P - Heat Pump - high eff.
F - Blower Only (No Cool)
Example:
PSC040B018A
- Condo Pack
- Single Packaged Vertical
- Condensing Gas heating 40k Btu/h
- Rev B AC 1.5 ton
- Rev A
A
018
COOLING
CAPACITY
REVISION
A, B, C...
i.e. PSC040F000A
W415-1307 / B / 03.31.2017