5.2

FURNACE SHUTDOWN

1� Set the room thermostat to below set point.
2� Remove the burner compartment access door.
3� Turn the gas valve switch to the "OFF" position.
4� The furnace appliance shut-off valve may be closed if desired.
5. Power to the furnace must remain ON for the air conditioner to work.
IF YOU INTEND TO BE AWAY FROM HOME FOR LENGTHY PERIODS OF TIME DURING
THE NON-HEATING SEASON, IT IS ADVISABLE TO FOLLOW THE FURNACE SHUT DOWN
SHOULD OVERHEATING OCCUR OR THE GAS BURNERS FAIL TO SHUT OFF, CLOSE THE
MANUAL GAS VALVE FOR THE FURNACE BEFORE SHUTTING OFF THE ELECTRICAL
POWER TO THE FURNACE. FAILURE TO DO SO CAN CAUSE AN EXPLOSION OR FIRE
RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
5.3

AIR CONDITIONING STARTUP

While operating, the AC Module will remove humidity from the air. This humidity will condense on the
evaporator coil and eventually fall in the drain-pan below the coil. There is a rubber hose ("P -Trap") that
takes the water collected to the building service drain. Before initial operation and/or at the beginning of each
cooling season, it is important that this P-trap is primed. If the P-trap dries out, air can be drawn back up the hose
pulling condensate off the coil, getting the air filter and other components wet. On how to prime the
condensate trap, refer to the instructions "4.8 Condensate Drain Connection".
1� Turn the Thermostat to COOL mode.
2� Set the room thermostat to below the current temperature to turn on AC.
3� Wait for the fan and compressor to turn on and run the unit for at least 10 minutes.
4� Power to the air conditioner must remain on for the furnace to work.
AIR CONDITIONER MUST NOT BE OPERATED WHEN OUTDOOR TEMPERATURE
IMPORTANT
!
PROCEDURE.
WARNING
!
BEFORE RESTARTING THE FURNACE,
CHECK ALL PLASTIC VENTS AND WIRES FOR DAMAGE.
WARNING
!
IS BELOW 55°F.
!
!
NOTE
!
45
H3.24.1
W415-1307 / B / 03.31.2017