Warning messages
of the control
WARNING
10
Motor servicing due
11
Compressor servicing
due
15
Suction control and /
or ventilation
18
Fault of an external
control
19
Power-up phases too
short
20
Continuous contact of
an external control
21
Receiver inspection due
or replace wearing parts
29
Control unit ENTER
key
does not open
BOGE base control for screw compressors
1.5
Possible cause
Servicing intervals
Servicing intervals
Warning
Higher level (Master) control
faulty
Coil short circuit ‚Solenoid
valve' or ‚Delta contactor'
according to the per-
missible amount of motor
cycle switches automatically
increased delay time
Higher level (Master) control
faulty
Servicing intervals
Control unit defective
Faults
Rectification
see operating instructions for servicing
see operating instructions for servicing
Check suction controller
Check solenoid valve
Check continuous output control (option)
Check supply voltage of master control. Parameterization
of external output release.
Otherwise have control repaired or replaced by BOGE-
Service personnel.
Have coil replaced by BOGE-Service personnel, check
lines and have them repaired, if necessary.
Check supply voltage of master control. Parameterization
of external output release.
Otherwise have control repaired or replaced by BOGE-
Service personnel.
Inspect receiver according to local rules and / or replace
wearing parts
Have control replaced by BOGE-Service personnel