134
Decision threshold for asymmetry
Default value 6 corresponds approximately to 0.7 volt asymmetry and thus to the
forward voltage of a silicon diode.Values smaller 3 are not useful, values greater 6
on demand.
135
Multiplication speed check-back signal
0 = disconnected
136
Division speed check-back signal
0 = /1, 1 = /2, 2 = /4, 3 = /8, 4 = /16, 5 = /32, 6 = /64
137
Settings
Bit
Function
0
Unamplified function outputs instead of ZCLK and ZDAT
(Not relevant to PD05A/PD12A)
1
Switch off energy saving mode
2
Invert SUSI-driving direction
(Not relevant to PD05A/PD12A)
3
Switch off SUSI-starting delay
(Not relevant to PD05A/PD12A)
4
Activate extended function mapping
(see CV131 and CV137/bit 5)
(Not relevant to PD05A/PD12A)
5
0 = AUX3 and AUX4 on ZCLK and ZDAT
1 = AUX5 and AUX6 on ZCLK and ZDAT
(Only valid if CV137/bit 0=1 and bit 4=1)
(Not relevant to PD05A/PD12A)
Explanations to bit 0, bit 4 and bit 5: see end of the table
138
Timer for approach
Each 100 ms, 0 = no approach
139
Timer for waiting
Each 100 ms, 0 = no waiting
Value
16
32
(Not relevant to PD05A/PD12A)
(Not relevant to PD05A/PD12A)
38
0 – 15
(See CV27)
0 – 255
0 – 6
0 – 63
1
2
4
8
0 – 250
0 – 250
(6)
(0)
(0)
(0)
(0)
(0)