Installing the Underbench Appliance
Tapware
The design of the tapware supplied depends on
the model ordered.
The illustra ons show the required connec ons
and are common to all tapware designs.
Where no Mixing Tap is to be installed (3‐in‐1
models) there will be no Mixing Tap connec ons
on the appliance.
Ventilation
Where no chiller is installed, the cupboard doors
must be kept ajar to increase ven la on to the
appliance.
This is achieved by applying the supplied 4mm
adhesive spacers/bump‐ons to the inner centre
corners (opposite to hinged ends) of each
cupboard door. Four spacers/bump‐ons are
supplied with the Dispensing Tap kit.
Chiller installations
For installa ons where a chiller is to be installed,
please refer to separate instruc ons supplied
with the chiller.
A
chiller
will
have
requirements, refer to the chiller's installa on
instruc ons.
Before proceeding to commissioning, ensure
installa on of chiller is complete.
Connections to water supply and Dispensing Tap
All connec ons to the Boiling Water Appliance are on the top face and are labelled.
The required hoses and pipes are supplied with the appliance.
A 15mm flexible hose is provided to connect the inlet supply water from the site isola on valve to the fi ng marked
SUPPLY INLET.
The connec ons to the Dispensing Tap are shown on page 4.
Push the end of the supplied silicon tube over the Dispensing Tap's Vent pipe a minimum of 12mm. Lead the silicon tube to
the connec on on the appliance marked VENT. The silicon tube must have con nuous fall from the Dispensing Tap with no
ght bends or kinks. Mark the silicon at the required length, allowing 12mm for fi ng to the appliance vent connec on. Cut
the silicon tube to length and fit to the appliance vent connec on.
Repeat this for the connec on between the Dispensing Tap's Boiling Water pipe and appliance BOILING OUTLET connec on.
When a chiller is installed the water supply to the chiller is taken from the Boiling Water Appliance's FILTERED OUTLET, a
6mm push‐fit connec on. Use the supplied white Ø6mm tube. Please refer to the chiller instruc ons.
Where no chiller is installed fit the supplied push‐fit Adaptor Fi ng to the Filtered/Chilled Water pipe of the Dispensing Tap.
Connect the white Ø6mm tube between the FILTERED OUTLET and the Adaptor Fi ng.
Connect the Tap Signal cable to the Appliance Tap Signal, matching 8 pin header, ensuring the orienta on of the header is
correct.
specific
ven la on
Dispensing Tap
Pipe Adaptor Fi ng
15mm Flexible Hose
Inlet Connec on
Ø12mm Silicon Tube
Vent
Ø12mm Silicon Tube
Boiling Water
Ø6mm Pipe
Filtered Water
Tap Signal 8 Pin Header
Chiller Signal 4 Pin Header
Mixing Tap
7