INSTALLATION
AND OPERATING
INSTRUCTIONS
C-5 Latching
Lockout
Module
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids or other combustible materials in the vicinity of this or any other appliance.
To do so may result in an explosion or fire.
NOTE: The instructions in this manual are for the use of qualified individuals specially trained and experienced
in the installation and maintenance of this type of equipment and related system components. Installation and
service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install,
service, or maintain this equipment.
This manual should be maintained in legible condition and kept adjacent to the variable speed pump or in a safe
place for future use.
APPROVED
UNCONTROLLED DOCUMENT IF PRINTED
Effective: 10-20-21
Replaces: 04-09-08
P/N 240722 Rev. 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Raypak C-5 Latching Lockout Module and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rheem Raypak C-5 Latching Lockout Module

  • Page 1 INSTALLATION APPROVED AND OPERATING INSTRUCTIONS C-5 Latching Lockout Module FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance. To do so may result in an explosion or fire. NOTE: The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components.
  • Page 2 APPROVED Please Register Now… And receive the full privileges of a Raypak controls user. Simply complete and return the attached card. This information helps us to access ordering information in case of loss, damage or theft. We will contact you in the unlikely event that any adjustments or modifications are ever required for your unit.
  • Page 3: Table Of Contents

    APPROVED TABLE OF CONTENTS 1. WARNINGS ...............4 Pay Attention to these Terms ........4 2. INTRODUCTION ............5 3. INSTALLATION AND MOUNTING ......5 4. MECHANICAL INSTALLATION .......6 Electrical Characteristics ........... 6 Electrical Installation ..........6 5. CHECK YOUR POWER SOURCE ......6 6.
  • Page 4: Warnings

    APPROVED 1. WARNINGS Pay Attention to these Terms Indicates the presence of immediate hazards which will cause severe personal injury, death or substantial DANGER property damage if ignored. ndicates the presence of hazards or unsafe practices which could cause severe personal injury, death or WARNING substantial property damage if ignored.
  • Page 5: Introduction

    APPROVED 2. INTRODUCTION DECAL OVERTORQUE / WIRE RATING Thank you for selecting the Raypak C-5 Latching Lockout Module (kit 006042 for field-installation). It is our sincere DECAL MODEL hope that you will enjoy it's outstanding design and ease BOX GROUP ID/DATE CODE of use.
  • Page 6: Mechanical Installation

    APPROVED 4. MECHANICAL NOTE: 18AWG stranded wire must be used for all connections to the circuit board. Solid conductors INSTALLATION should not be used because solid wire conductors can cause excessive tension on contact points. Install the Module, as shown in Figure 3, on the side of the boiler.
  • Page 7: Field Wiring Connection Points

    APPROVED 6. FIELD WIRING CONNECTION POINTS NOTE: Tighten terminal strip clamping screws to 4 in-lbs. Breakage from over-torquing is not covered under warranty. Use 18 AWG stranded copper conductors only. For supply connections, use 18AWG stranded or larger wires rated at min. 75°C (167°F). C-5 BOARD DRY CONTACTS AVAILABLE FOR REMOTE FAULT INDICATION...
  • Page 8: Field Wiring Installation

    APPROVED 7. FIELD WIRING 8. INSTALLATION INSTALLATION VERIFICATION PROCEDURE The C-5 Module is installed in series between the Boiler Control and the ignition module. Register Refer to the wiring diagram for the required wire connections on the boiler. Before proceeding any further, please verify that the user registration form has been completed and mailed.
  • Page 9: Warranty

    APPROVED 11. WARRANTY LIMITED WARRANTY C-5 Latching Fault Detector SCOPE OF WARRANTY : Raypak, Inc. ("Raypak") warrants to the original owner the Control System to be free from defects in materials and workmanship under normal use and service for the applicable warranty period. In accordance with the terms of this Limited Warranty, RAYPAK will furnish a replacement or repair, at our option, any defective part which fails in normal use and service during the applicable warranty period.
  • Page 10 APPROVED NOTES Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 UNCONTROLLED DOCUMENT IF PRINTED...

Table of Contents