Rheem 743 Series Owner's Manual & Installation Instructions page 11

Underbench boiling water appliances
Table of Contents

Advertisement

Setting Timer ON/OFF Times
Clock is 24hr  me.
Se ng an iden cal ON/OFF  me will make the appliance 
ac ve for 24 hrs. 
Prog => Set ON/OFF  mes => Accept
Display Shows: SUN 7:00 ­ 7:00 Set ON hour
Note: The hour digit will flash to indicate edi ng
Press Up to change the hour value. Press Accept
Display Shows: SUN 7:00 ­ 7:00 Set ON minute
Note: The minutes digits will flash to indicate edi ng
Press Up to change the minute value. Press Accept
Display Shows: SUN 7:00 ­ 7:00 Set OFF hour
Note: The hour digit will flash to indicate edi ng
Repeat procedure above to set Off  me.
Pressing  Accept  will  advance  throught  On  and  Off  mes 
for the week.
Setting Sleep Delay Time
Prog => Sleep Delay Time => Accept
Display Shows: Sleep Delay Time OFF
The  Sleep  Delay  func on  puts  the  unit  in  a  standby 
mode a er a user‐defined period (1 ‐ 6 hours).
Press  UP  bu on  to  increase  the  sleep  delay  me  up  to 
six hours.
Press Accept to confirm selec on, display reverts to the 
main menu.
Filter Life
On first opera on, the Filter Life needs to be setup.
Prog => Filter Life => Accept
Display Shows: Remaining Life COUNT IS OFF
Press UP to access filter reset.
Display Shows: Filter Reset. Press Accept
Display Shows: Are you Sure. Press Accept
Display Shows: Set Filter Life xxxx Litres
Press UP to select filter life value. Press Accept
Pressing UP scrolls from the filter OFF selection up 
to  12,000  litres.  We  recommend  a  default  value  of 
4,000  litres,  until  the  user  knows  the  filter  will  last 
longer.
Filter Life Reset
Prog => Filter Life => Accept
Display Shows: Remaining Life xxxx Litres
Press UP to access filter reset.
Display Shows: Filter Reset. Press Accept
Display Shows: Are you Sure. Press Accept
Display Shows: Set Filter Life xxxx Litres
Press Up to select filter life value. Press Accept
10
Service Menu
Through  the  service  menu,  various  opera onal 
parameters  can  be  viewed  and  set.  Should  error 
condi ons  arise  they  can  be  displayed  to  assist  service 
technicians.
Prog => Service => Accept
Press UP to cycle through sub menu.
Service Menu Selection
Press "Up" to cycle through menu
Error Codes
Boiling Temp
Chiller Temp
Calib Reset
Temp. Override
So ware Version
Temp Show ON/OFF
TB Treq
Press "Accept" to select choice
Error Codes
Error Codes => Accept
Display error codes if present. Ref box on page 11. 
Boiling Temp
Display current boiling water temperature
Up => Boiling Temp => Accept
Display Shows: xx ° C
Chiller Temp
Display current chilled water temperature
Up => Chiller Temp => Accept
Display Shows: xx ° C
Calibration Reset
Force boiling point recalibra on.
Up => Calib Reset => Accept
Display Shows: Are you Sure? Press Accept
Display Shows: Calibrating Do Not Interrupt
Temp. Override
Manually set boiling water temperature.
Up => Temp. Override => Accept
Display Shows: xx ° C Press UP to set temperature
Set range is 70° to 99° C. Press Accept
Display Shows: Are you Sure? Press Accept
Software Version
Display installed so ware version
Up => So ware Version => Accept
Display shows installed so ware version on two lines.

Advertisement

Table of Contents
loading

Table of Contents