Summary of Contents for GW Instek PEL-2000A Series
Page 1
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com Programmable DC Electronic Load PEL-2000A Series USER MANUAL GW INSTEK PART NO. 82EL-2004AEA1 ISO-9001 CERTIFIED MANUFACTURER...
Page 2
January 2016 This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of the Good Will company. The information in this manual was correct at the time of printing. However, Good Will continues to improve products and reserves the right to change specification, equipment, and maintenance procedures at any time without notice.
PEL-2002A/PEL-2004A, and when keeping it in storage. Read the following before operating the PEL-2002A/2004A to ensure your safety and to keep the PEL-2000A series in the best possible condition. Safety Symbols These safety symbols may appear in this manual or on the PEL- 2002A/2004A.
Page 6
PEL-2000A Series User Manual Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased. Safety Guidelines Do not place any heavy object on the PEL- General ...
Page 7
SAFETY INSTRUCTIONS AC Input voltage: 115V/230V switchable, Power Supply 50/60Hz WARNING The power supply voltage should not fluctuate more than 15%. Connect the protective grounding conductor of the AC power cord to an earth ground, to avoid electrical shock.
Page 8
PEL-2000A Series User Manual (Pollution Degree) EN 61010-1:2010 specifies the pollution degrees and their requirements as follows. THE PEL-2002A/2004A falls under degree 2. Pollution refers to “addition of foreign matter, solid, liquid, or gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity”.
Page 9
SAFETY INSTRUCTIONS Power cord for the United Kingdom When using the PEL-2002A/2004A in the United Kingdom, make sure the power cord meets the following safety instructions. NOTE: This lead/appliance must only be wired by competent persons WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code: Green/ Yellow:...
Page 10
PEL-2000A Series User Manual ETTING STARTED This chapter describes the features and functions of the PEL-2002A/2004A, including the front and rear panel appearance, panel installation and connection types. Use the Tutorial section for quick access to step by step instructions on the main functions.
The flexible module configuration allows the mainframes to either sink multiple loads independently or large loads when used in parallel. The PEL-2000A series support four operation modes: constant current (CC), constant voltage (CV and CV+CC), constant resistance (CR) and constant power (CP). Constant current and constant resistance mode can operate in either static or dynamic mode.
GPIB (optional) Series Overview The PEL-2000A series comprises of two different Mainframes: the PEL-2002A and the PEL-2004A. The Mainframes differ by the number of load modules that can be accommodated. The PEL- 2002A has two load module slots whilst the PEL-2004A has 4. There are 4 different load module models, the PEL-2020A, PEL-2030A, PEL-2040A and PEL-2041A.
Page 14
PEL-2000A Series User Manual The 4 different load module models each differ in the amount of current, voltage and power and the number of channels that the load module can accommodate. The procedures in this manual will be load module model independent unless specifically stated.
Description Accessories Power Cable Mains power cable (region dependent) CD ROM Contains PEL-2000A Series Electronic DC Load User Manual, Programming Manual and USB Driver GTL-120 Load cables 2X red, 2X black (per load module) GTL-121 Remote sense cables , 1X red, 1X black (per load...
PEL-2000A Series User Manual Measurement Overview The PEL-2000A series has a number of different operating modes that are completely configurable. All the modes have customizable Go/NoGo limits, range limits, timers, slew rates, alarms and protection limits. For parallel loads, there is a dedicated Parallel configuration mode.
GETTING STARTED Front Panel Overview PEL-2002A DC Electronic Load LCD display Function keys LOCAL UTILITY System Keys CHAN FUNC FILE HELP Selector Knob Number Pad Operation PRESET SHIFT CAL. LOCK keys ON / CLEAR ENTER LOAD USB input Power 320 by 240, TFT LCD display. LCD display Assigned to the menu functions on Function keys...
Page 18
PEL-2000A Series User Manual CHAN/LOCAL is used to select System Keys LOCAL the load channel. Combined with CHAN the shift key, Local is used to activate/deactivate local control (during remote control via the interface or frame link connections). Brings up the LOCAL Channel Menu.
Page 19
GETTING STARTED Enter numerical values, or to Number pad save/recall presets (P0-P9). Number values. CAL. LOCK CLEAR Preset numbers P0- PRESET Decimal point and Calibration key CAL. Decimal point. CAL. Activate calibration CAL. SHIFT mode. Please note, calibration mode is not supported. Note Please see your distributor for calibration needs.
Page 20
PEL-2000A Series User Manual Used to select operations and to Selector Knob increase/decrease values. When turned left or right moves the cursor in menus or changes the selected item or value. When pushed down, acts as the Enter key. Saves and recalls preset settings...
Page 21
GETTING STARTED The shift key is used to access SHIFT alternate functions assigned to select keys. The shift key is also used to toggle between coarse and fine control mode when used in conjunction with the selector knob to adjust parameters.
Page 22
PEL-2000A Series User Manual Turns the unit on or into standby Power mode. Standby mode.
GETTING STARTED Display Overview – Mainframe Mainframe Status Alarm Panel A Value 80.00 V *CH1 B Value 80.00 V Curr Limit 40.00 A Current Main SPEC Operation Screen Slow Channel Status Panel main Menu Response Mode Configure Configure Icons Slow The Mainframe Status Panel displays the status of Mainframe Status the Mainframe interface, programs and alarm...
Page 24
PEL-2000A Series User Manual Load Type The Load Type Icon LOAD indicates if a Sequence LOAD (SEQ) or Program (PROG) is turned on. If PROG not then LOAD is PROG displayed as default. When any Load type is running, their icon will turn orange.
Page 25
GETTING STARTED Mode Displays the current mode. CC Static Low Range CC Static High Range CCDL CC Dynamic Low Range CCDH CC Dynamic High Range CR Static Low Range CR Static High Range CRDL CR Dynamic Low Range CRDH CR Dynamic High Range CV Mode CP Low Range CP High Range...
Page 26
PEL-2000A Series User Manual F1~F5 Each Menu Icon is controlled by Menu Icons the F1~F5 function keys directly below.
GETTING STARTED Rear Panel Overview PEL-2004A Go/NoGo Output GPIB GO / NG OUTPUT RS232C RS232C SER. NO. LB GPIB FRAME CONT USB-B REPLACE FUSE terminal AS SPECIFIED FUSE RATING 115V T 3.15A 180 VA MAX 230V 250V 50/60 Hz WARNING CH CONT 8 CH CONT 7 CH CONT 6...
Page 28
PEL-2000A Series User Manual The RS232 and GPIB port is RS232 port/ used for remote control GPIB port connections. RS232C RS-232C: DB-9 pin male GPIB: 24-pin female See pages 268, 269 for remote control details. The USB-B (device) port, like...
Page 29
GETTING STARTED The power supply socket Power Socket/ accepts the AC mains Voltage. Fuse The fuse holder is located below the power socket. Power: 50/60 Hz (180 VA) Fuse: T3.15A/250V For fuse replacement details see page 277. Each channel has a dedicated Channel CH CONT 1 Channel control port to...
PEL-2000A Series User Manual Front Panel Overview – Load Module DC Electronic Load L 20A / 80V , 100W PEL-2020A 20A / 80V , 100W LED display Static/ Dynamic R/L A/B Key STATIC/ R / L DYNA. Display Key Slave Knob...
Page 31
GETTING STARTED Current Voltage Power Load time Activates the load for the active Load Key LOAD channel. (Right or Left)(A or B) The voltage sense terminals are Left Voltage V sense used when precise measurement is Sense needed. V Sense terminals are used to compensate for voltage drops 80V DC across the main terminals caused...
Page 32
PEL-2000A Series User Manual For 2 channel load modules, the left Positive and terminals are used for the 1 Negative Terminals Right channel and the right terminals are 80V DC used for the 2 channel. On single channel load modules,...
Page 33
GETTING STARTED The SHORT key is used to Short Key SHORT manually short circuit the active channel on the local active load. When a load is off, the SHORT key will toggle the Short key type. Hold: Hold the SHORT key to short the channel load.
PEL-2000A Series User Manual LED Display Overview – Load Module & Channel Display Left and right channel indicator. 5 digit display. Indicates the channel number & (1-8). Channel Number Indicator Indicates if the load is active on the load module. (Dual channel...
Page 35
GETTING STARTED The Mode Indicator LEDs will indicate what the current mode or settings are on the active Mode Indicator channel(s). Value A or B for a single channel load module. Applies to CR, CV, CP and CC static mode only. Constant Current Mode (CC) mode activated.
Page 36
PEL-2000A Series User Manual Lights up when in Dynamic mode. Lights up when a load is shorted. Lights up when Go/NoGo is activated and the load fails (NG) the Go/NoGo limits. The Unit Indicators display the current & unit. Channel Unit...
GETTING STARTED Installation The installation chapter describes how to load the different load modules, install the optional GPIB card, the rack mount kit and how to determine each channel number. Load Module Installation To avoid static electricity, please use appropriate anti- WARNING static work practices.
Page 38
4. Install any additional modules as described above. 5. If there are any slots empty, install the supplied panel cover (GW Instek part number: 63FP-AG106501). The panel cover will improve safety and increase air flow.
Page 39
GETTING STARTED 6. Use the supplied screws to fix the panel cover(s) over the load slot.
PEL-2000A Series User Manual GPIB Installation To avoid static electricity, please use appropriate anti- WARNING static work practices. The PEL-2004A and 2002A has GPIB as an option GPIB Card (GW Instek part no. PEL-001). installation Steps 1. Ensure the mainframe is disconnected from mains power.
The PEL-2004A can be used in a standard 19” rack Background mount enclosure with the optional rack mount kit (GW Instek part no. 11EL-20040201). Each unit requires a rack height of 4U with a 1U space for ventilation top and bottom. The rear of the rack mount enclosure must be free of obstruction to allow heat to dissipate from the mainframe(s).
PEL-2000A Series User Manual Channel Number The channel number for a module load is Description determined by which slot it occupies on the mainframe chassis. There can be 1 or 2 channels per slot, depending on the load module type.
GETTING STARTED Power Up & Self Test 1. Connect the power cord Panel operation to the power socket. 2. Turn the external power switch on. 3. Hold the power button on the front panel to turn on the power. The power button turns green from red (standby).
Page 44
PEL-2000A Series User Manual Initial System Success Success Success Success Success Success When the system check happens, the load modules will display each channel as it is checked, then display the current mode. 4. If any of the System checks fail, please power down the load generator and reinstall the appropriate load module(s).
GETTING STARTED Load Connections Precautions and Procedures The PEL-2000A load generator supports a number Introduction of different load configurations for flexible operation. Single DUT, single load Single DUT, parallel load Multiple DUTs, multiple loads Multiple DUTs, multiple mainframe loads ...
Page 46
PEL-2000A Series User Manual Wires that are selected must be large enough to Wire Selection withstand a short circuit and limit voltage drops to no more than 2V per wire. Use the table below to help make a suitable selection.
Page 47
GETTING STARTED Current ∆I time ∆T Voltage Min. V time The diagram above shows how changes in current can affect voltage. Load line inductance can be reduced by ensuring Limiting Load line inductance load wires are as short as possible and by twisting positive and negative load wires together.
Page 48
PEL-2000A Series User Manual The PEL-2000A supports single and dual channel Load module considerations load modules. Single channel load modules have one bank of negative terminals and one bank of positive terminals. Each terminal pair has a 40A capacity. For higher loads, each terminal can be wired in parallel to increase capacity.
Page 49
GETTING STARTED 80V DC 80V DC 4. Close the terminal cover securely. Ensure the wires are secured properly and that the wires are not exposed when the cover is in place. Ensure that the wires are tied or twisted together to WARNING prevent noise and inductance.
PEL-2000A Series User Manual Remote (Sense) Connection The electronic load modules have two voltage Background sense contacts: Vsense L(black), Vsense R(red). Voltage sense can be used to help compensate for long cable length. The longer the cable, the higher the potential resistance and inductance, therefore a short cable is best.
Page 51
GETTING STARTED The voltage sense terminals use a screw-less clamp Remote Sense Terminal connector. The clamp must be opened prior to connection inserting a wire. Use a small screwdriver to push the clamp release mechanism. Insert both wires then release the clamp mechanism. V sense 80V DC...
PEL-2000A Series User Manual Single Load Connections A dual channel load module can be used to sink Dual Channel Load Module two loads concurrently. Connection Dual channel Twisted Load Module Pair Twisted Pair On a single channel load module, the left terminals...
Page 53
The diagram below shows a typical connection. Load Module Auxiliary Using an auxiliary power supply may induce reverse WARNING current. The PEL-2000A series has reverse voltage protection. For details see the protection section on page 87.
PEL-2000A Series User Manual Parallel Load Connections When the power output of a DUT exceeds the Parallel load modules power rating of a channel or load module, the channel terminals, load modules or mainframes can be used in parallel to dissipate more power when used in CC or CR mode.
Page 55
GETTING STARTED Parallel load Single Channel Load Module Single Channel Load Module Single Channel Load Module Single Channel Load Module Please note that the same load modules must be used Note in parallel. The PEL-2000A mainframes can also be connected Parallel loads in parallel.
Page 56
PEL-2000A Series User Manual The PEL-2000A is also able to sink a number of Multi-output power supply loads concurrently from multiple DUTs or sink a load number of loads from the same DUT (i.e. multiple output power supply). Dual channel...
GETTING STARTED Frame Link Connection Frame link control involves connecting multiple Background mainframes using the frame link connections. Up to 4 slave mainframes can be connected to the master mainframe. The first mainframe (master) can be used to control the other slave frames. There is a delay time of 2ms between the master and first slave mainframe, and 4ms, 6ms, and 8ms to the second, third, and fourth slave mainframes,...
Page 58
PEL-2000A Series User Manual The first mainframe that is connected is the master frame; any additional frames are slave units. The ribbon cable connects to the master from connector 2, and the slave from connector 1. Each successive slave unit is connected in a cascading manner the same way.
GETTING STARTED Channel Control Connection The Channel Control connecters are located on the Background rear panel of each mainframe. There are two channel control connectors for each load slot, one for each channel, if applicable. The channel control connector is used to externally: Turn on/off loads.
Page 60
PEL-2000A Series User Manual The external voltage reference input must be External Voltage between 0~10V. Connection EXT VREF Twisted External Pair Voltage Ensure the external voltage reference is stable and has WARNING low noise. The External Voltage should be no more than 10V.
Page 61
GETTING STARTED The Voltage Monitor Output (VMON) and Current Voltage and Monitor Output (IMON) output the load input Current Monitor Output voltage and load input current as a percentage of rating current/voltage. Where 0 volts = 0% rating and 10 volts = 100% load input rating voltage or current.
PEL-2000A Series User Manual Go/NoGo Connection The Go/NoGo port is a 15 socket port. Each Background channel has a dedicated line for a Go/NoGo output. The ports are open-collector with active low (1.1V) indicating a pass and active high (30V) as fail (an alarm).
GETTING STARTED PERATING DESCRIPTION Operating Mode Description ........... 64 Constant Current Mode ....... 64 Constant Resistance Mode ....67 Constant Voltage Mode ......70 Constant Power Mode ......73 Parallel Unit Mode ............75 Run Program ..............77 Sequence ................ 80 OCP Test Automation ............
PEL-2000A Series User Manual Operating Mode Description There are four basic operating modes: constant current (CC), Constant Resistance (CR), Constant Voltage (CV/CV+CC) and Constant Power (CP). All channels operate using any of the modes. Each mode has a number of configurable options including slew rate, levels, protection modes, Go/NoGo and extensive save options.
Page 65
GETTING STARTED There are two selectable ranges for constant current Range mode: high and low range. Low range has a higher resolution, but a lower range. If the current exceeds the Low Range, High range must be used. Static Functions Static mode tests the stability of the voltage output from a power source.
Page 66
PEL-2000A Series User Manual CC Mode: Dynamic Current Level 1 Level 2 Time Timer 1 Timer 2 Timer 1 The slew rate is the rate at which the current will Slew rate increase to a set level. There are two slew rates: rising slew rate &...
GETTING STARTED CC Mode: Static:Go/NoGo Current Load Current NoGo NoGo Voltage CC Mode: Dynamic:Go/NoGo Current Level 1 Level 2 NoGo Voltage GO is specified as between the Low and High Go/NoGo limits. NoGo is specified as outside the Go/NoGo limits. Constant Resistance Mode In Constant Resistance Mode the load units will Background...
Page 68
PEL-2000A Series User Manual CR Mode Load Input Voltage Load Current Resistance Range There are two ranges: High and Low. The Low range is used for low voltage ranges, whilst the High range uses high voltage ranges. The current range always remains in High range, regardless of the selected voltage range.
Page 69
GETTING STARTED Dynamic CR Mode Load Input Voltage Load Current Timer 1 Timer 2 Timer 1 The rising and falling slew rate (A/uS) determines Slew Rate the speed at which the load levels change from A to B Value (Static mode) or from Level1 to 2 (Dynamic mode) and vice versa.
PEL-2000A Series User Manual Constant Voltage Mode In Constant Voltage Mode the load units will sink Background current whilst keeping the voltage constant. Single channel load modules support 2 values (A Value, B Value) and have an adjustable cut-off current limit. Dual channel load modules only have A value.
Page 71
GETTING STARTED CV Mode Voltage A value B value Time When using CV mode, a current limit can be set for CV + CC CV + CC mode. When the voltage input is greater than A Value (load voltage) then the channel will operate in CV mode if the input current is less than the current limit.
Page 72
PEL-2000A Series User Manual Response Speed Response speed can be set to fast or slow. Fast response and slow response is determined by the load module specifications. Slow response speeds are suitable for large loads as quick current changes will induce induction which can cause large voltage drops.
GETTING STARTED Constant Power Mode In Constant Power Mode the load units will ensure Background a constant power load for the power supply. Single channel load modules support 2 values (A Value, B Value) and have an adjustable cut-off current limit. Dual channel load modules only have A value.
Page 74
PEL-2000A Series User Manual CP Mode A Value B Value Load Current High/Low Range There are two ranges: High and Low. The Low range is used for low power ranges, whilst the High range uses high power ranges. CP Mode...
GETTING STARTED Parallel Unit Mode The Parallel configuration menu allows load Background modules of the same type and rating to be configured as a single unit when used in parallel. This saves the hassle of configuring each channel individually. Parallel Configuration is only supported under CC and CR mode.
Page 76
PEL-2000A Series User Manual Consider 3 load modules set to CC mode in CC Example Parallel. In CC mode the total current for all units is the sum of each unit. Total For example, to set a total load current of 90A, the Current Level setting in Para mode would be 90A, whilst it would be 30A in Sync mode.
V/I, V/W, I/W, S. The displayed units can only be controlled through this menu. Run Program The Program function on the PEL-2000A series Background supports a total of 12 different programs at any one time with 10 sequences to each program. Up to 12 programs can be chained together.
Page 78
PEL-2000A Series User Manual Each Sequence has a number of configuration options that apply to all the channels equally. Sequence Item Description Memory Loads the channel settings for each load module Range: M001~M120 Sets the running configuration for the current sequence. The sequence can be skipped, run or run manually only.
Page 79
GETTING STARTED If less than 10 Sequences are desired for a Program, any additional Sequences can be skipped (not run). Program 1 Sequence (P01) Sequence 2 & 3 are skipped. Any of the 12 programs can be chained together to Program Chain create a Program Chain.
PEL-2000A Series User Manual Sequence The Sequence function is used to create high Background resolution load simulations. Each Sequence can be configured to create a unique load profile to accurately simulate loads in real time. Sequences are only applicable for CC (Static) and CR (Static) modes.
Page 81
GETTING STARTED Up to 120 points can be used with each Sequence. Points Each point can have a different duration, slew rate and value. A new point can be inserted or deleted at any stage of a Sequence. Any new points that are inserted will have a value averaged from its neighbors as default.
Page 82
PEL-2000A Series User Manual If more than one Sequence is programmed on the On End Of Seq. mainframe, the On End Of Seq. function will hold function the load current (of the selected sequence) to a designated value until all the other sequences have finished running.
Page 83
GETTING STARTED Value Time Trigger Sequence Trig Time As can be seen above, a trigger sequence signal is output for every rising edge point. The Trigger In setting allows a sequence to start Trig In after a trigger (Trig Out) has been received via the frame link connector.
Page 84
PEL-2000A Series User Manual Value Time Value Time Below shows the resulting sequence when CH1 imports CH2. CH1 imports the duration time settings and number of points from CH2, but not the value data. CH1 import CH2 Value Time...
GETTING STARTED OCP Test Automation The OCP test function creates an automatic test to Background test the over current protection of power supply products. See page 179 for operation details. This test will test to see when the over current protection of a power supply is tripped and return the measurements for the voltage and current when the over current protection was tripped.
PEL-2000A Series User Manual Parallel Dynamic Loading The PEL-2000A series of DC electronic loads Background support parallel dynamic loading. This simply means that when the load modules of a mainframe are connected in parallel and set to dynamic mode, they can perform dynamic tests synchronously following the same clock.
The Configuration Description section describes what the different configurations are used for and how they can be relevant to different operations. Protection Modes The PEL-2000A series include a number of Background protection modes: Over Current Protection, Over Voltage Protection, Over Power Protection, Under voltage protection and Constant Power Protection.
Page 88
PEL-2000A Series User Manual When a load unit is operating in CR, CV or CP Over Current mode, the unit may need over current protection to Protection prevent excessive current being sunk. Over current protection stops the load from sinking more current than its recommended limit which can cause damage to the unit.
OPP is tripped power will cease to be sunk. Reverse voltage protection prevents reverse voltage Reverse voltage damage to the PEL-2000A series up to the specified Protection rating. When Reverse voltage protection has been tripped an alarm tone will sound until the reverse voltage is removed.
Page 90
PEL-2000A Series User Manual Von Voltage is the voltage limit at which the load Von Voltage will start to sink current. There are two operation modes for Von Voltage: Von latched: ON and Von latched: OFF. Latched: ON will sink current when Von has been tripped, and will continue to sink current even if the voltage drops below the Von Voltage.
Page 91
GETTING STARTED When short mode is on, the load unit can simulate a Short short circuit. Shorting can be individually set for each channel when programming sequences. To initiate a short circuit manually, the short key is used. It can be used at any time during an operation.
Page 92
PEL-2000A Series User Manual Load Delay time is used to delay activating a load Load D-Time (up to 10 seconds) after the load key has been pressed. However the Load D-Time setting will only work for loads that are initiated manually or when the PEL series mainframe is configured to Auto load (page 217) at run time.
GETTING STARTED Channel Control External channel control is used with the Channel Background Control connectors. Each channel control connector can activate each load, monitor voltage and current and has an external voltage reference input. The voltage and current monitors output 0~100% of the rated current/voltage as a voltage of 0~10V.
Page 94
PEL-2000A Series User Manual To determine the Percent Rating (voltage or current load input), use the following formula; External Voltage Load Input Rating VorA Where “Rating V or A” is the rating voltage/current of the load module.
Page 95
GETTING STARTED Voltage Monitor The input voltage, like the load input current can be externally monitored with the channel control connectors. The VMON pin of the channel control connector outputs a voltage of 0~10V to represent the load input voltage as a percentage (0~100%) of the rating voltage.
Page 96
PEL-2000A Series User Manual A load is turned on when Load On input is set to Turning on the On (active low). A load is turned off when the Load Load On input is set to Off (active high). When a load is turned on from the channel control interface, the load can be turned off from the mainframe, local module and via remote control.
GETTING STARTED Interface and File System Interface The PEL-2000A series support RS232, GPIB and Background USB remote frame control. Only one type of connection is supported at any one time. For connection options and configurations see the options below. RS-232 configuration.
Page 98
PEL-2000A Series User Manual data type. Thus files are saved/recalled for each channel and each data type. Preset data can be saved into 10 memory slots for Preset Data each channel. Preset data contains the mode, range, CV response speed and Go/NoGo settings.
Page 99
GETTING STARTED SEQ data contains Sequence data. SEQ data can SEQ Data only be saved to and from USB. SEQ refers to Sequence data, not Program sequences. Internal Format N/A (Internal buffer) External Format 20X0X_XX.A SEQ Contents SEQ data contains the following data; Seq.Edit ...
Page 100
PEL-2000A Series User Manual Active Channel (CH01~08) CHAN Mode Static/Dynamic Range CV response speed Go/NoGo SPEC Test Entry Mode High Center When saving data to internal memory, either the Save: Internal...
Page 101
GETTING STARTED Save/Recall USB In order to save data from a single channel to USB, data must first be saved to the internal memory. After data is saved to internal memory, all the files can be saved to USB. Channel X Internal Memory File.M Memory Data...
PEL-2000A Series User Manual File Format Single Channel Filename format 1: PEL series Load module 2030R_00.M Memory data type: Preset data 1 2 3 4 2020 = PEL-2020A SEQ data 2030 = PEL-2030A 2040 = PEL-2040A 2041 = PEL-2041A 2: Channel...
Page 103
GETTING STARTED All Channel Directory Format 1: All Channel common ALL_0000 directory name 2: Directory number: 0000 ~ 0099 All Channel File Format 1: PEL series Load module 2030R_C1.M Memory data type: Preset data 1 2 3 4 2020 = PEL-2020A SEQ data Setup Data 2030 = PEL-2030A...
PEL-2000A Series User Manual UTORIALS (Step by Step Operations) Local loads ..............105 Single Channel Load ............107 Parallel Load Modules ............ 109 Programming ..............111 Sequences ..............113 Frame Link ..............114 Channel Control ............. 116 General Configuration Options ........118...
TUTORIALS Local loads Local mode operation is useful to quickly test loads using the load module control panel rather than the mainframe control panel. Local load modules can be configured to operate independently to the mainframe. This can be useful when settings need to remain unchanged on the mainframe.
Page 106
PEL-2000A Series User Manual The local load modules can be set Page 198 8. Independent to independent load. load Slave knobs can be configured to Page 223 9. Independent be independent to the mainframe. control Display Measured or Set Values Page 227 10.
TUTORIALS Single Channel Load Single channel loads are used to manually test a DUT quickly or to configure channel settings for Program Sequences using the mainframe panel. Step Description Details Choose the appropriate load Page 37 Setup module and make sure it is installed.
Page 108
PEL-2000A Series User Manual Set the Go/NoGo configurations, Page 206 9. Go/NoGo if applicable. Configure the protection modes. Page 188 10. Protection Modes Activate the load by pressing the 11. Run ON / LOAD load key. Optional 12. Configuration There are number of...
TUTORIALS Parallel Load Modules The Parallel Unit configuration setting allows for a quick and easy parallel setup for load modules of the same type and rating. However, the Parallel Unit configuration settings only apply for CC and CR modes. Step Description Details Choose the appropriate load...
Page 110
PEL-2000A Series User Manual Set the Go/NoGo configurations, Page 206 9. Go/NoGo if applicable. Configure the protection modes. Page 188 10. Protection Modes Activate the load by pressing the 11. Run ON / LOAD load key. Optional 12. Configuration There are number of...
TUTORIALS Programming When creating a Program Sequence or Chain, all channels are used at the same time unless programmed otherwise. Program Sequences use the channel settings stored from Memory Data. Program sequences are primarily used to perform a battery of pass/fail tests on DUTs.
Page 112
PEL-2000A Series User Manual Save everything to the internal Page 241 12. Save Setup Setup memory. Run the Program Page 163 13. Run Sequence/Chain.
TUTORIALS Sequences Sequences are used to accurately simulate loads. As each Sequence is independent, Sequences are ideally suited to test multiple output power sources. Step Description Details Choose the appropriate load Page 37 Setup module(s). Connect the terminals to the DUT. Page 45 2.
PEL-2000A Series User Manual Frame Link Frame link connections are used connect up to four slave main frames to a master main frame. When using frame link connections it is possible to perform a number of operations in parallel under the control of the master unit.
Page 115
TUTORIALS Options Load preset memory on the Page 265 5. Load Preset mainframe and all frame-linked memory slaves. Load setup memory on the Page 264 6. Load Setup mainframe and all frame-linked Memory slaves Press shift + CHAN on the slave LOCAL 7.
PEL-2000A Series User Manual Channel Control The Channel Control connectors on the rear panel can be used to control and monitor the status of up to 8 channels. For more information on channel control, see page 93. External control Step...
Page 117
TUTORIALS Use IMON and VMON to monitor Page 93 9. Monitor the current and voltage of load outputs. To turn the load off, output an 10. End active high signal to the channel control connector, or press the LOAD key on the load module or mainframe**.
PEL-2000A Series User Manual General Configuration Options There are number of different options for each channel. The different options are described below. Options Description Details Configure the CC Voltage range Page 192 1. CC Vrange from high or low. Configure the Von Voltage settings. Page 194 2.
OPERATION PERATION The PEL series operation is described in the chapters below. The sections are broken down into small operations. For thorough examples on the operation of the load generator, please see the tutorial section on page 105. Local Mode Operation ............ 123 Selecting a Channel ......
Page 120
PEL-2000A Series User Manual Editing CR Static Parameters ..... 145 Select CV Mode ........148 Editing CV Parameters ....... 149 Select CV Response Speed ....151 Select CP Mode ........152 Editing CP Parameters ....... 153 Select CP Range ......... 155 Creating a Program Sequence .........
Page 121
OPERATION Configuring Response Time ....206 Go/NoGo ........... 208 Parallel Unit ........211 View Parallel Information ....213 Mainframe Configuration ..........215 Accessing System Information ... 216 Accessing the Load Menu ....217 Adjusting the Speaker ......218 Adjusting the Display Settings ... 219 Adjusting the Frame Control ....
OPERATION Local Mode Operation Each channel can be edited by its local load module. Depending on the configuration, local changes can be reflected on the mainframe. For this section all operations refer to knobs and buttons on the local load module panels, unless stated otherwise. Local Mode Operation ............
PEL-2000A Series User Manual Selecting a Channel Each channel can be individually selected by using Background its load module panel. Changing channels on a load module only applies to dual channel load modules. Press any key on a load module to...
OPERATION Selecting Static/Dynamic Each load channel can be individually switched Background from Static to Dynamic using the local load module. 1. Select a channel on the load Page 124 module. 2. Press the STATIC/DYNA. key to Panel operation STATIC/ switch from dynamic to static DYNA.
PEL-2000A Series User Manual Turning on the Load Loads can be individually selected to be turned on Background using local operation. 1. Select a channel on the load Page 124 module. 2. Press the LOAD key to turn on Panel operation LOAD the load.
OPERATION Shorting The short key can be set to toggle or hold. Background 1. Ensure the load is off. 2. Select a channel on the load Page 124 module. 3. Press the SHORT key to change Panel operation SHORT between shorting modes. When the load is on, the SHORT key needs to be...
PEL-2000A Series User Manual 4. Press LOAD to turn on the load. LOAD 5. a. Press the SHORT key (toggle Shorting SHORT mode). b. Hold the SHORT key (hold mode). The load cannot be shorted from the local load Note module in Parallel mode.
OPERATION Editing CC/CR/CV/CP A/B Value The Slave Knob is used to edit the A Value or B Background Value (single channel load module) when in static mode. The Slave Knob can also operate in fine or coarse editing mode. Panel Operation 1. Ensure the mode is in static Page 125 mode.
PEL-2000A Series User Manual Mainframe Basic Operation For the Mainframe Basic Operation section, all operations refer to the knobs and keys on the main configuration panel, unless otherwise stated. Mainframe Basic Operation ..........130 Help Menu ......... 131 Channel Selection ......132 Select CC Mode ........
OPERATION Help Menu When any function key has been pressed or when Background a menu has been opened, the HELP key can be used to display a detailed description. 1. Press a function or system key on the front panel or open a UTILITY menu.
PEL-2000A Series User Manual Channel Selection There are up to 2 channels per load module, Background depending on the model. The main display can be used to control each channel individually. When Parallel Unit configuration is enabled, channel selection is disabled. See page 195 for details.
OPERATION Select CC Mode Background The PEL-2000A series load generators operate in four different modes: Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), and Constant Power (CP). When a channel is active, the F1 key can be used to switch between each operating mode.
PEL-2000A Series User Manual Select CC Range Constant current mode can run in high and low Background range. Maximum range is dependent on the load module. Ensure the menu is in CC Mode. See page 133. Mode Range Dynamic Configure...
OPERATION Select CC Dynamic Mode Constant current mode can be set to dynamic or Background static mode. Dynamic mode is used to automatically set varying load rates. Ensure the menu is in CC Mode. See page 133. Mode Range Dynamic Configure Configure High...
Page 136
PEL-2000A Series User Manual Level1 0~rating A Parameters Level2 0~rating A SlewRate Load module dependent SlewRate Timer1 0.025~30000.0 ms Timer2 0.025~30000.0 ms When used in parallel mode, the Level1 & Level2 Note range is the combined rating of all the units used in parallel mode.
OPERATION 2. Press the Selector knob to edit the selected level, then turn to increase or decrease the value*. Use the number pad to enter a number. CAL. LOCK CLEAR Level1 0.80 3. Press the Selector knob or Enter ENTER to confirm selection.
PEL-2000A Series User Manual Panel Operation 1. Press the F3 key until Static mode is selected. Dynamic Static Changing from static to dynamic mode will only affect Note the current (active) channel. Editing CC Static Parameters When using a single channel load module, Static...
Page 139
OPERATION Panel Operation 1. Use the Selector knob to highlight A Value. Single Channel Parallel Unit Configuration Configuration LOAD LOAD A Value 0.80 A Value 0.80 CH1P 0.80 B Value 0.80 B Value SlewRate 0.80 A/uS SlewRate 0.80 A/uS SlewRate 0.80 A/uS SlewRate...
Page 140
PEL-2000A Series User Manual The last Value (A Value or B Value) that is set becomes Note the active setting. To swap between A Value and B Value, use the A/B keys on the local load module. This is not applicable to Parallel Unit mode.
OPERATION Set to CR Mode The PEL-2000A series load operates in four Background different modes, Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR) and Constant Power (CP). Constant Resistance mode will maintain a constant resistive load, using variable current and voltage levels.
PEL-2000A Series User Manual Panel Operation 1. Press the F2 (Range) key repeatedly until High or Low range is selected. Range Range High The range will be reflected in both the bottom menu system and the Current Operation Channel Status panel.
OPERATION Panel Operation 1. Press F3 until Dynamic Range mode is selected. Dynamic Static Changing from static to dynamic mode will only affect Note the current (active) channel. Editing CR Dynamic Parameters Dynamic Constant Resistance Mode has two CR levels operating resistance levels, slew rates and timers.
Page 144
PEL-2000A Series User Manual When used in parallel mode, the Level1 & Level2 Note range is the combined rating of all the units used in parallel mode. Panel Operation 1. Use the Selector knob to highlight Level1. Level1 100.000 Ω...
OPERATION Level1 & Level2 can be set for both High and Low Note Range. *Press Shift to toggle between coarse and fine adjustment when editing the Level1 and Level2 parameters. See page 202 for details. Select CR Static Mode Constant Resistance mode can be set to dynamic or Background static mode.
Page 146
PEL-2000A Series User Manual Ensure the menu is in CR Static Mode. See page 145. Mode Range Seq. Static Configure Configure Edit Ω A Value 0~rating Parameters Ω B Value 0~rating SlewRate Load module dependent SlewRate Switch Value A/B (Parallel Unit only) When Parallel Unit is enabled, the A Value &...
Page 147
OPERATION A Value 100.000 Ω 3. Press the selector knob or Enter ENTER to confirm selection. 4. Repeat steps 1-3 for B Value (if applicable), rising and falling SlewRate. The last Value (A Value or B Value) that is set becomes Note the active setting.
PEL-2000A Series User Manual Select CV Mode The PEL-2000A series electronic load operates in Background four different modes, Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), and Constant Power (CP). CV Mode cannot be used with the Parallel Unit mode.
OPERATION Editing CV Parameters Constant Voltage mode can be set to a maximum Background limit (Curr Limit). Using the current limit enables limiting the current draw. When using CV mode on single channel load modules, two voltage levels can be sunk, A Value and B Value.
Page 150
PEL-2000A Series User Manual A Value 10.00 B Value 15.00 Curr Limit 10.00 Slow main Response Mode Configure Configure Slow 2. Press the Selector knob to edit the selected value, then turn to increase or decrease the value*. Use the number pad to enter a number.
OPERATION Select CV Response Speed Constant voltage mode has fast and slow response Background speeds. Quick current changes can induce line voltage, making it more difficult for the PEL load generator to maintain a constant current. In these types of conditions, slow response speed is recommended.
PEL-2000A Series User Manual Select CP Mode The PEL-2000A series electronic load operates in Background four different modes, Constant Current (CC), Constant Resistance (CR), Constant Voltage (CV), and Constant Power (CP). CP mode cannot be used with the dedicated Parallel Unit mode.
OPERATION Editing CP Parameters Constant Power mode can be set to have a Background maximum limit (Curr Limit). Using the current limit enables limiting the current draw. When using CP mode on a single channel load module, two power levels can be configured, A Value and B Value.
Page 154
PEL-2000A Series User Manual A Value 10.00 B Value 20.00 Curr Limit 7.140 main Range Mode Configure Configure 2. Press the Selector knob to edit the selected value, then turn to increase or decrease the value. Use the number pad to enter a number.
OPERATION Select CP Range Constant Power mode can run in high and low Background range. Range is dependent on the load module. Ensure the menu is in CP Mode. See page 148. Mode Range Configure Configure Panel Operation 2. Press the F2 (Range) key repeatedly until High or Low range is selected.
PEL-2000A Series User Manual Creating a Program Sequence The PEL-2000A series has a total of 12 different Background programs and 10 sequences to each program. That totals to 120 different configurations. Each Sequence in each program uses the settings saved from Memory Data (Memory MXXX).
Page 157
OPERATION Memory M001~M120 Parameters Skip-Auto-Manual On-Time 0.1 ~ 60.0 S Off-Time Off – 0.1 ~ 60.0 seconds P/F Time Off – 0.1 ~ (On-Time+Off-Time)-0.1 Short-Time Off – 0.1 ~ On-Time Before a program can be created, the settings for each Note sequence for every channel that is to be used in the program must first be pre-configured and saved into...
Page 158
PEL-2000A Series User Manual 3. Press the selector knob to edit PROG:, then turn to select the program number. Use the number pad to enter a CAL. LOCK program number. CLEAR Program: 01 ~12 4. Press Enter or push the selector ENTER knob to confirm.
Page 159
OPERATION Choose which Memory data will be used for the sequence. CH1 MXXX ~ CH8 MXXX. Run: Skip – Auto - Manual Choose whether to run the sequence in the program automatically, skip the sequence or manually start the sequence. On-Time: 0.1 ~ 60.0 seconds Determines how long the sequence will run for (seconds).
Page 160
PEL-2000A Series User Manual The Pass(P)/Fail(F) Time can be set to 0.1 seconds less than the total test time. The total test time is defined as: On-Time + Off-Time (seconds) If Go/NoGo is turned on but the pass fail time is off, then Go/NoGo test will continue, but there will not be a specified pass/fail time window.
OPERATION Program Chains On the PEL-2000A, there are up to 12 different Background programs containing 10 sequences. If 10 sequences in a Program Sequence prove to be inadequate for testing, the PEL2000A series can chain different programs together, effectively making a larger Program Sequence. Unlike Program Sequences, Program Chains do not need to be run in numerical order.
Page 162
PEL-2000A Series User Manual LOAD Start Sequence Chain Set Edit Previous Recall Save Configure Start Default Menu 4. Use the selector knob to edit Start and confirm which Program Sequence (PXX) will start the program chain. Any Program (P01~P12) can be used to start a Program Chain.
OPERATION 7. Repeat the above procedure to P02~P12 to complete the program chain. The Program Chain ends at the first Program (PXX) that is followed by Off. It is possible to create continuously looping program chains. 8. Press F3(Save) to save the Save Program program chain.
Page 164
PEL-2000A Series User Manual 3. Press the FUNC key, Program FUNC (F1) and Active Channel (F2). Channel 1 (CH01) will be highlighted. Note CH1 has CH CONT set to External LOAD Active Channel for Program Mode Active Prog Recall Previous...
Page 165
OPERATION 9. Press F5 (Previous Menu) to Previous Menu return to the Sequence menu. 10. Press F1 (Prog) to turn On or Off Turn Program On/Off the current Program. Pressing F1 will cycle from Program On to Off. Prog Prog 11.
Page 166
PEL-2000A Series User Manual As each sequence or program is completed the screen will update to display the active sequence/program. Notice that if a channel has been set up with Go/NoGo limits, a pass (GO) or fail (NG) will be displayed on the main display as well as the local load module display.
Page 167
OPERATION PROG PASS FAIL PASS PASS Detail Configure Exit When the program has finished, the physical channels that have run will be displayed, a PASS or FAIL will be displayed if Go/NoGo testing has been set. 16. When the program has finished, press F1 to see any result details.
Page 168
PEL-2000A Series User Manual Use the Selector knob to scroll down to view the remainder of the list if necessary. 17. Press F5 to exit at any time. Upon exiting, the previous menu before running the program will load.
OPERATION Edit Sequence The Sequence function can be configured to create Background a unique load profile to accurately simulate loads in real time for single or multiple loads. Sequence can only be used with CC static or CR static modes. For details see page 80. Each Sequence is composed of a number of points with customizable current/resistance, slew rate and duration times.
Page 170
PEL-2000A Series User Manual LOAD Point 0.00 Value Duration Time 0.000025 SlewRate 2.80 A/uS SlewRate 2.80 A/uS s_edit Delete Previous Loop Configure Point Point Menu 3. Use the Selector knob to highlight Value. 4. Press the Selector knob to edit the Value, then turn to increase or decrease the value.
Page 171
OPERATION 8. To add an extra point after the Add Point current point, press Add Point (F1). Range 001~120 Add Point will insert a new point directly after the Note current point. The value of the current/resistance of the inserted point will be the average of the point before and after.
PEL-2000A Series User Manual Create Sequence Loop Sequences can be looped a number of times. The Background loops can be started at any point in the sequence. The Start of Loop function determines which point will start each repeating loop.
Page 173
OPERATION LOAD Repeat 0005 Times Start of Loop Point On End Of Seq. CC Vrange High s_loop Previous Save Configure Menu 2. Use the Selector knob to highlight Repeat. 3. Press the Selector knob to edit Repeat, then turn to increase or decrease the value.
PEL-2000A Series User Manual Channel Duration Time Settings Each sequence can have the timing duration data Background of another sequence. For example CH1’s sequence can import the timing duration settings of CH2’s sequence. This is useful to quickly compare two different loads to the same timing characteristics.
Page 175
OPERATION 1. Press FUNC, then Sequence (F2) Panel operation FUNC to enter the Channel Duration Time menu. LOAD Channel Duration Time Setting TRIG Setting IN/OUT Seq. TRIG In Define TRIG In Save Configure TRIG OUT Channel Note CH3 is set to TRIG OUT, whilst CH1 & CH3 are set to TRIG IN.
PEL-2000A Series User Manual 5. Press Define TRIG OUT (F2) if Trigger Out you want the currently selected Channel channel to output the Trigger sequence signal. One channel must be set as the TRIG OUT channel. 6. Press TRIG In Channel (F4) to...
Page 177
OPERATION Ensure the Channel Duration Time Page 174 Settings have also been configured and that no Sequence (CH01~08) that you wish to run are set to OFF. 1. Press FUNC, then Sequence (F2) Panel operation FUNC to enter the Channel Duration Time Setting menu.
Page 178
PEL-2000A Series User Manual Channel Duration Time Setting Setting TRIG Run SEQ Mode 6. Press the LOAD key again or Stop the load ON / LOAD wait for the Sequence (if not infinitely looped) to end/stop the load. 7. Press Seq. (F1) to turn OFF the...
OPERATION OCP Test Automation The OCP test function creates an automatic test to Background test the OCP of power supply products. Active Channel Applies the setting to the Parameters load channel. Range High(CC Mode High) or Low(CC Mode Low) Start Current(Start C) Starting current value for the test.
Page 180
PEL-2000A Series User Manual Last Current(Last_C) Sets the final current value after OCP has been tripped. This is the steady-state current draw after the OCP has been tripped. Step Time(Step_T) Sets the execution time of each step. (50mS to 1600S) Delay Time(Delay) The OCP testing delay time.
Page 181
OPERATION 2. Use the Selector knob to highlight the parameter you want to edit. 3. Press the Selector knob to edit the parameter, then turn to increase or decrease the value. Use the number pad to enter a number. CAL. LOCK CLEAR 4.
Page 182
PEL-2000A Series User Manual 7. To select the load channels for Select Active Channel the test, press Active Channel (F2).
Page 183
OPERATION 8. Use the selector knob to Enter ENTER key to turn the Active value to 9. Press Save (F3) to save the OCP Save the OCP test automation channel. Test Automation Channel 10. Press Previous Menu (F5) to return to the OCP Test Automation menu.
Page 184
PEL-2000A Series User Manual 12. Press Save (F3) to save the OCP Save the OCP test automation parameters. Test Automation Parameters 13. Press the Load key to start to Start the OCP ON / LOAD OCP Test Automation. Test Automation 14.
Page 185
OPERATION An OCP Test Automation example using actual current and voltage waveforms.
PEL-2000A Series User Manual Channel Configuration The Channel Configuration chapter describes the configuration options for individual channels. Any configuration settings that are changed only apply to the current channel, other channels will not be changed. Channel Configuration ........... 186 Accessing the Configuration Menu ..187 Setting (OCP/OVP/OPP/UVP) ...
OPERATION Accessing the Configuration Menu The configuration menu is used to access Background instrument settings and properties as well as set the protection levels for each channel. 1. Select the channel to be Panel operation LOCAL configured by pressing the CHAN CHAN key and using the Selector knob.
PEL-2000A Series User Manual Setting (OCP/OVP/OPP/UVP) Over Protection is used to set the voltage, current Background or power limit. In the event that the current, voltage or power exceeds the over protection settings, the load module alarm will show an error message and beep an alarm.
Page 189
OPERATION LOAD OCP Level 71.400 CCDH OCP Setting OVP Level 81.6 OVP Setting OPP Level 357.00 OPP Setting conf Previous Protection Other Go-NoGo Parallel Configure Menu 1. Use the Selector knob to highlight OCP Level. 2. Press the Selector knob to edit the selected level, then turn to increase or decrease the value.
Page 190
PEL-2000A Series User Manual 6. Use the selector knob to turn ON, OFF or CLEAR the OCP Setting. 7. Repeat steps 1-5 for : OCP Level OVP Level OVP Setting OPP Level OPP Setting UVP Level UVP Setting Clearing an Alarm When any of the protection settings are tripped, Alarm will be shown on the Mainframe Status Panel and an alarm tone will sound by default.
OPERATION OCP Setting Clear *REV, OTP and CPP cannot be cleared using this Note method, the Protection Clear function must be used instead, see page 191. See pages 62 and 274 to output alarms via the Go/NoGo output terminal. The configuration settings only apply to the current channel.
PEL-2000A Series User Manual Ensure the menu is in the Panel operation configuration menu. See page 186. Previous Protection Other Go-NoGo Parallel Configure Menu 1. Turn the load off by pressing the ON / LOAD load key if necessary. 2. Use the selector knob to scroll down to Protection Clear.
Page 193
OPERATION LOAD CC Vrange High CCDH Von Voltage Von Latch Short Key Toggle CH CONT Panel Independent conf Previous Protection Parallel Configure Other Go-NoGo Menu 2. Use the Selector knob to highlight CC Vrange. 3. Press the Selector knob to edit CC Vrange, then turn to increase or decrease the range.
PEL-2000A Series User Manual Adjusting the Von Voltage and Latch The Von Voltage is the voltage point at which the Background load module will start to sink current. When Von latch is set to ON, the load will continue to sink current after being tripped, even if the voltage drops below the Von Voltage level.
OPERATION 3. Press the Selector knob to edit the selected value, then turn to increase or decrease the value. Use the number pad to enter a number. CAL. LOCK CLEAR Von Voltage 4. Press the Selector knob or Enter ENTER to confirm selection.
Page 196
PEL-2000A Series User Manual LOAD CC Vrange High CCDH Von Voltage Von Latch Short Key Toggle CH CONT Panel Independent conf Previous Protection Other Go-NoGo Parallel Configure Menu 2. Use the Selector knob to highlight Short Key. 3. Press the Selector knob to edit the selected setting, turn to change the setting.
OPERATION Configuring Channel Control When Channel Control (CH CONT) is set to Background External, it will disable editing the active channel load. Instrument buttons and knobs can still be used to access the menu for the active channel or to edit other channels that do not have channel control active.
PEL-2000A Series User Manual 3. Press the Selector knob to edit the selected setting, turn to change the setting from Panel to External. CH CONT External 4. Press the Selector knob or Enter ENTER to confirm selection. Channel control is now activated. To...
Page 199
OPERATION Ensure the menu is in the Panel operation configuration menu. See page 186. Previous Protection Other Go-NoGo Parallel Configure Menu 1. Press the F2(Other) key to enter the Other menu. LOAD CC Vrange High CCDH Von Voltage Von Latch Short Key Toggle CH CONT...
PEL-2000A Series User Manual When a channel has been set to *CH1 independent, an asterisk(*) will be shown next to the channel number CCDH indicator in the Current Operation Channel Status panel. Note The configuration settings only apply to the current channel, other channels will not be affected.
Page 201
OPERATION LOAD Load D-Time CCDH CCH Step 0.002 CCL Step 0.0010 A CRH Step 0.00080 CRL Step 0.00080 CV Step conf Previous Protection Parallel Configure Other Go-NoGo Menu 2. Use the Selector knob to highlight Load D-Time. Note: Load D-Time is below Independent, off-screen.
PEL-2000A Series User Manual Configuring Step Resolution The CC, CV and CR step resolution settings can be Background edited in the configuration menu. These step resolution settings directly correspond to the step resolution of the coarse adjustment when setting the CC, CR and CV parameters.
Page 203
OPERATION CCH Step HR/40000 HR/2 Amperes A PEL-2030A (R) CCL Step LR/40000 LR/2 Amperes A ℧ CRH Step HR/40000 HR/2 Siemens ℧ CRL Step LR/40000 LR/2 Siemens CVH Step HR/40000 HR/2 Voltage V CVL Step HR/40000 HR/2 Voltage V CPH Step HR/25000 HR/2 Watt W...
Page 204
PEL-2000A Series User Manual Use the Shift key to toggle between coarse and fine Note adjustment mode when editing the CC, CR and CV values with the Selector knob on the main display. The fine adjustment resolution varies between the function and load module used.
Page 205
OPERATION Ensure the menu is the configuration Panel operation menu. See page 186. Previous Protection Other Go-NoGo Parallel Configure Menu 1. Press the F2(Other) key to enter the Other menu. LOAD Load D-Time CCDH CCH Step 0.002 CCL Step 0.0010 A CRH Step 0.00080 CRL Step...
PEL-2000A Series User Manual 4. Press the Selector knob or Enter ENTER to confirm selection. 5. Repeat steps 2-4 to edit the step resolution of: CCL Step CRH Step CRL Step CV Step The Step resolution settings only apply to the active Note channel, other channels will not be affected.
Page 207
OPERATION LOAD CCH Step 0.002 CCDH CCL Step 0.0010 A CRH Step 0.00080 CRL Step 0.00080 CV Step Response Normal conf Previous Protection Other Go-NoGo Parallel Configure Menu 2. Use the Selector knob to scroll down to highlight Response. Note: Response is off-screen when entering Other menu.
PEL-2000A Series User Manual Go/NoGo Background Go/NoGo mode is used to set threshold limits. When a load is within the limit(s) it is considered to be “Go”, when the load has exceeded the limit it is considered to be “NoGo”.
Page 209
OPERATION 2. Use the selector knob to edit Entry Mode. 3. Choose Value for absolute limits or Percent for percentage offset limits. Entry Mode Value Entry Mode Percent 4. The menu changes according to the selection. Value Percent LOAD LOAD SPEC Test SPEC Test CCDH...
Page 210
PEL-2000A Series User Manual 8. Choose ON to turn on Go/NoGo. SPEC test 9. Choose OFF to turn off Go/NoGo. SPEC test When SPEC test is set to ON, SPEC will be displayed in the Current CCDH Operation Channel Status panel.
OPERATION Parallel Unit Background The Parallel Unit Configuration menu allows load modules of the same type and rating to be configured as a single unit when used in parallel. Up to 4 load modules can be used in this mode. Operating the PEL-2000A load modules in Parallel Unit mode is almost identical to using the load modules separately.
Page 212
PEL-2000A Series User Manual 3. Press (F4) Parallel to access the Parallel Setup Parallel menu. LOAD Parallel Unit CCDH Parallel Mode Para Display Mode conf Previous Protection Other Go-NoGo Parallel Configure Menu 4. Use the Selector knob to change Parallel Unit from the OFF setting to the number of parallel units.
OPERATION 8. Use the selector knob to change Display Mode the display settings on the local load modules. 9. Choose from V, I / V, W / I,W or S. Display Mode When Para Unit is active, an indicator will be displayed on the CH1P screen.
OPERATION Mainframe Configuration The Mainframe Configuration chapter describes configuration settings that apply to all channels and general interface settings. Mainframe Configuration ..........215 Accessing System Information ... 216 Accessing the Load Menu ....217 Adjusting the Speaker ......218 Adjusting the display settings .... 219 Adjusting the Frame Control ....
PEL-2000A Series User Manual Accessing System Information The System Information displays the mainframe Background and load module(s) serial numbers. MainFrame Ver: Mainframe firmware version and Parameters date (month/day). PEL-200X SN: Mainframe Serial number. SlotX(Y)Ver: The version number of the Xth load module occupying the Xth slot with channel number Y.
OPERATION Accessing the Load Menu The PEL series is able to automatically start Background loading from the last program or load setting. If Auto Load On is set to Load, the last load setup used before the machine was reset will automatically start to load upon startup.
PEL-2000A Series User Manual 4. Press the Selector knob or Enter ENTER to confirm selection. 5. Scroll to Auto Load On and choose Load or Program for the next time the PEL-2000A starts Adjusting the Speaker The PEL series has an internal speaker for both the Background mainframe and load modules.
OPERATION 3. Use the Selector knob to highlight Speaker. 4. Press the Selector knob to edit Speaker, then turn to change from On to Off and vice versa. Speaker 5. Press the Selector knob or Enter ENTER to confirm selection. Adjusting the Display Settings The PEL series has a TFT LCD display.
Page 220
PEL-2000A Series User Manual LOAD Other Setting Speaker Contrast Brightness Frame CONT Alarm Tone(M) System Load Interface Configure Other Info 3. Use the Selector knob to highlight Contrast. 4. Press the Selector knob to edit contrast, then turn to increase or decrease the value.
OPERATION Adjusting the Frame Control Frame control is used to control a number of Background different frame linked mainframes (slaves) with a master mainframe. For information on frame control, frame control interface and connection see pages 57 & 271. Note: When using frame control, ensure the same firmware is installed in both master and slave units.
Page 222
PEL-2000A Series User Manual 4. Use the Selector knob to highlight Frame CONT. 5. Press the Selector knob to edit, then turn to turn Frame CONT (frame control) ON or OFF. LOAD Other Setting Speaker Contrast Brightness Frame CONT Alarm Tone(M)
OPERATION Adjusting the Knob Control Type The load module control knobs can be set to Background operate independently to the mainframe. With the Knob type set to Updated, dependent operation is activated. Both the local (load module) selector knob and mainframe selector knob can change the resistance (CR mode), current (CC mode), voltage (CV mode) and power (CP mode).
PEL-2000A Series User Manual 3. Use the Selector knob to move the cursor down to Knob Type (below the initial screen). 4. Press the Selector knob to highlight Knob Type, then turn to change to Old/Updated. Knob Type Updated 5. Press the Selector Knob or Enter ENTER to confirm selection.
OPERATION LOAD Other Setting Brightness Frame CONT Alarm Tone(M) Alarm Tone(S) Knob Type Updated System Load Interface Configure Other Info 3. Use the selector knob to highlight Alarm Tone(M) 4. Press the Selector knob to select the master alarm (Alarm Tone(M)), turn to edit and press to confirm selection.
Page 226
PEL-2000A Series User Manual 1. Press the Shift Key then the Help Panel operation UTILITY HELP SHIFT key to access the Utility menu. 2. Press F5 (Other Menu). LOAD Other Setting Alarm Tone(S) Knob Type Updated Go_NoGo Tone SetValue Slave Knob...
OPERATION Adjusting Slave Knob Settings Channel loads can be edited using the local load Background module or the Mainframe. When using the slave knob to edit a load, the load module display can be set to two different types: SetValue and Measured. When a load is ON, SetValue will always display the set value (A Value, B Value) on the local load module display whilst “Measure”...
Page 228
PEL-2000A Series User Manual 3. Use the Selector knob to move the cursor down to Slave Knob (below the initial screen). 4. Press the Selector Knob to highlight Slave Knob, then turn to change to Measure/SetValue. Slave Knob SetValue 5. Press the Selector Knob or Enter ENTER to confirm selection.
OPERATION View Language Settings The language settings can be viewed in the Background Utilities menu. 1. Press the Shift Key then the Help UTILITY Panel operation HELP SHIFT key to access the Utility menu. 2. Press F5 (Other Menu). LOAD Other Setting Alarm Tone(S) Knob Type...
PEL-2000A Series User Manual Interface Configuration (settings) The Interface Configuration chapter describes configuration settings that apply when using the PEL-2000A with a remote connection. There are three interface options for remote control: RS232, GPIB and USB. Only one interface can be used at a time. For more details about remote control and interface connections, see the Interface section on page 267.
OPERATION Configuring RS232 Connection When using RS232 a number of parameters need to Background be set. These include Baud rate, Stop Bit and Parity. When setting RS232 parameters, ensure they match that of the host machine. Baud Rate 2400/4800/9600/19200/38400 Parameters Stop Bit Parity None/Odd/Even...
Page 232
PEL-2000A Series User Manual 5. Press the Selector knob to ENTER confirm. 6. The RS232 Menu appears. RS232 LOAD Interface RS232 Baud rate 38400 Stop Bit Parity None System Load Interface Configure Other Info 7. Use the Selector knob to edit Baud rate, Stop Bit and Parity.
OPERATION Configuring the GPIB Address When using GPIB, an address must be specified. Background Parameters Address 01~30 1. Press the Shift Key then the Help Panel operation UTILITY HELP SHIFT key to access the Utility menu. 2. Press F3(Interface Menu). LOAD Interface System...
Page 234
PEL-2000A Series User Manual GPIB LOAD Interface GPIB Address System Load Interface Configure Other Info 7. Use the selector knob to edit the ENTER GPIB address. The GPIB Address must match that of the host Note machine. Configuring USB Remote Connection...
Page 235
OPERATION RS232 LOAD Interface RS232 Baud rate 38400 Stop Bit Parity None System Load Interface Configure Other Info 3. If the Interface mode is not USB, use the Selector knob to edit Interface. 4. Choose USB. Interface 5. Press the Selector knob to ENTER confirm.
PEL-2000A Series User Manual Save / Recall Save / Recall ..............236 Saving/Recalling Channels ....237 Saving/Recalling Preset memory ..239 Saving/Recalling Setup Memory ..241 Setting the Default USB Path/File ..243 Saving Setups to USB Memory ... 248 Saving/Recalling Memory Data to USB251 Saving/Recalling Presets to USB ..
OPERATION Saving/Recalling Channels The PEL-2000A series can save data for up to 120 Background different channel configurations. Each channel is represented by 120 memory slots using the onboard memory. Memory is used in program sequences or for individual channel setups. For further details on memory, see page 97.
Page 238
PEL-2000A Series User Manual Channel Data Current Data Type Memory 5. Press the Selector knob to edit Memory (M001-M120) Use the number pad to enter a number. CAL. LOCK CLEAR LOAD Channel Data Current CCDH Data Type Memory Memory M001...
OPERATION Saving/Recalling Preset memory The PEL-2000A series can store up to 10 presets for Background each channel. The presets can be saved or recalled either individually for each channel (Channel Data: Current) or at the same time (Channel Data: All), using the All option.
Page 240
PEL-2000A Series User Manual Save / Recall Channel Data Current Current Channel Data Type Preset Save / Recall All Channel Data Channels Data Type Preset 5. Press the Selector knob to edit Preset (P0-P9) Use the number pad to enter a number.
The display will revert to the channel menu after Note recalling memory. Saving/Recalling Setup Memory The PEL-2000A series can store up to 4 different Background setups using the onboard memory. Each setup can be saved from the file menu. Using Setup Memory, each channel will be saved.
Page 242
PEL-2000A Series User Manual Channel Data Data Type Setup 5. Press the Selector knob to edit Setup Memory (1~4) Use the number pad to enter a number. CAL. LOCK CLEAR LOAD Channel Data CCDH Data Type Setup Setup Memory file...
OPERATION Setting the Default USB Path/File When saving files to a USB memory stick the files Background will be saved into the root directory if a file path has not been set. 1. Insert a USB flash drive into the Panel operation front panel USB slot.
Page 244
PEL-2000A Series User Manual LOAD Path: usb: usb:\ New folder 05-Nov-13 20:55 UNTITL~1 25-Jul-14 03:16 29-Dec-13 15:59 Timing 29-Dec-13 16:10 17 folder(s), 13 file(s) Select Rename Delete Configure Previous Folder The top section (window) shows the current USB path. There are 5 options: ...
Page 245
OPERATION LOAD Path: usb: usb:\ New folder 05-Nov-08 20:55 25-Jul-14 UNTITL~1 03:16 29-Dec-13 15:59 Timing 29-Dec-13 16:10 17 folder(s), 13 file(s) Select Rename Delete Configure Previous Folder The new path will be shown in the upper Path box in green. Path: usb\New folder 7.
Page 246
PEL-2000A Series User Manual 9. When a key is ENTER highlighted, use the selector knob, F1 or Enter to confirm a key entry. 10. Use F2 (Back Space) to delete any previous entries/mistakes. 11. Press F3 (Save) to save the directory name.
Page 247
OPERATION The On Screen Keyboard appears Rename: New folder 15. Use the Selector knob to scroll left and right through the keys. 16. When a key is ENTER highlighted, use the selector knob, F1 or Enter to confirm a key entry.
PEL-2000A Series User Manual 22. To confirm deletion, press F4 again. Path: usb\New folder usb:\ New folder 05-Nov-08 20:55 UNTITL~1 25-Jul-14 03:16 29-Dec-13 15:59 Timing 29-Dec-13 16:10 Press F4 again to confirm this process. Select Rename Delete Configure Previous Folder...
Page 249
OPERATION 3. Press the File key. FILE 4. Press F1 repeatedly until the Media USB menu appears. Media Media Media Memory Default LOAD Save Chan Current CCDH Data Type Memory Save File 2030L_01.M Recall File 2030L_00.M Path: usb: file Media File Save Recall...
Page 250
PEL-2000A Series User Manual LOAD Save Chan CCDH Data Type Setup Save File 20040_01.S Recall File 20040_00.S Path: usb: file Media File Save Recall Configure Utility The screen will update to only show Setup files (*.S) that are available to save/recall in the default path directory.
OPERATION Saving/Recalling Memory Data to USB There are two options to save or recall Memory Background data to a USB flash drive: Save Chan Current: Saves the active Channel’s Memory data(M001~M120) into the default file path (20XXX_XX.M). Save Chan All: Every channel’s Memory data (CH1 M001~120 ~ CH8 M001~M120) will be saved into a directory (ALL00XX) as separate files for each channel (P0X0X_C1.M ~ P0X0X_C8.M).
Page 252
PEL-2000A Series User Manual 3. Press the File key. FILE 4. Press F1 repeatedly until the Media USB menu appears. Media Media Media Memory Default LOAD Save Chan Current CCDH Data Type Memory Save File 2030L_01.M Recall File 2030L_00.M Path: usb:...
Page 253
OPERATION LOAD Save Chan CCDH Data Type Memory Save Folder ALL0003 Path: usb: file Media File Save Configure Utility The screen updates to show Save Folder. Note it is not possible to recall all channels at once, only save. 7. Use the Selector Knob to edit Save Folder.
Page 254
PEL-2000A Series User Manual Save Chan Current Data Type Memory LOAD Save Chan Current CCDH Data Type Memory Save File 2030L_00.M Recall File 2020L_01.M Path: usb: file Media File Save Recall Configure Utility 13. Use the selector knob to edit Save or Recall File.
OPERATION Saving/Recalling Presets to USB There are two options to save or recall Channel Background Presets to a USB flash drive: Save Chan Current: Saves the active Channel’s Presets (P0~P9) into the default file path (20XXX_XX.P). Save Chan All: Every channel’s Presets (CH1 P0~P9 ~ CH8 P0~P9) will be saved into a directory (ALL00XX) as separate files for each channel (P0X0X_C1.P ~ P0X0X_C8.P)
Page 256
PEL-2000A Series User Manual 3. Press the File key. FILE 4. Press F1 repeatedly until the Media USB menu appears. Media Media Media Memory Default LOAD Save Chan Current CCDH Data Type Memory Save File 2030L_01.M Recall File 2030L_00.M Path: usb:...
Page 257
OPERATION LOAD Save Chan CCDH Data Type Preset Save Folder ALL0000 Path: usb: file Media File Save Configure Utility The screen updates to show Save Folder. Note it is not possible to recall all presets at once, only save. 7. Use the Selector Knob to edit Save Folder.
Page 258
PEL-2000A Series User Manual Save Chan Current Data Type Preset LOAD Save Chan Current CCDH Data Type Preset Save File 2020L_01.P Recall File 2020L_00.P Path: usb: file Media File Save Recall Configure Utility 13. Use the selector knob to edit Save File or Recall file.
OPERATION Saving/Recalling Sequences to USB There are two options to save or recall Sequences to Background a USB flash drive. Sequences can either be saved from all channels or from the current channel only. Save All: Every channels’ sequences will be saved into a directory (ALL00XX) as separate files for each channel (20XXX_C1.A~ 20XXX_C8.A).
Page 260
PEL-2000A Series User Manual 4. Press F1 repeatedly until the Media USB menu appears. Media Media Media Memory Default LOAD Save Chan Current CCDH Data Type Memory Save File 2030L_01.M Recall File 2030L_00.M Path: usb: file Media File Save Recall...
Page 261
OPERATION LOAD Save Chan CCDH Data Type Save Folder ALL0000 Path: usb: file Media File Save Configure Utility The screen updates to show Save Folder. Note it is not possible to recall all SEQ data at once, only save. 7. Use the Selector Knob to edit Save Folder.
Page 262
PEL-2000A Series User Manual Save Chan Current Data Type LOAD Save Chan Current CCDH Data Type Save File 2030L_01.A Recall File 2030L_00.A Path: usb: file Media File Save Recall Configure Utility 13. Use the selector knob to edit Save File or Recall File.
OPERATION Quick Preset Recall/Save The PEL-2000A series mainframes have up to 10 Background Channel Presets (P0~P9). Quick recalling or saving presets will only be applicable to the active channel. For example, P1 on CH1 is not the same as P1 on CH2.
PEL-2000A Series User Manual 6. Press the Preset key and one of Recall Current PRESET Channel Preset the number keys. 0 = P0 1= P0 etc. 7. Press the Shift key, the Preset Recall All Channel SHIFT PRESET Presets key and one of the number keys.
OPERATION Recall Preset Memory (Frame link) A master mainframe can command all units to Background recall preset memory from their internal memory. Only the first three preset memories (P0~P2) can be recalled. Channel presets can be recalled via the file menu or using the quick recall feature using the number pad.
PEL-2000A Series User Manual Recall Factory Defaults The Factory defaults can be recalled at any time. Background For details on the factory defaults please see the default settings in the appendix, page 285 Panel Operation 1. Press the File key.
PEL-2000A Series User Manual Interface Configuration Configure RS-232C interface DB-9, Male Connector RS-232C configuration 9600 Baud rate None Parity Data bit Stop bit Connect the RS-232C cable RS232C (GW Instek part no. GTL-232) to the rear panel port: DB-9 male connector.
INTERFACE Configure GPIB interface Connect the GPIB cable to the Connection rear panel port: 24-pin female connector. Pin assignment Data line 1 Pin13 Data line 5 Pin1 Data line 2 Pin14 Data line 6 Pin2 Data line 3 Pin15 Data line 7 Pin3 Data line 4 Pin16 Data line 8...
PEL-2000A Series User Manual Configure Channel Control interface Screwless connector. Channel control Connector configuration 22-28 AWG (24 AWG Wire Gauge recommended). 10 mm strip gauge for Wire connection connection. 10.0 mm 0-10V. Input Pin Assignment Negative potential of the load 1 GND input terminal.
INTERFACE Load On Input. 5 Load On Load on = Active low, 0-1V Load off = Active high, 4-5V. (Using the + load polarity in conjunction with a 10kΩ pull up resistor) Internal power output. Max 6 +15V 50mA. Mode and Range configuration Channel Control Mode/Range is only selected via the front...
PEL-2000A Series User Manual Input: active low (0-1V), active high (4-5V) Connection Inputs (5V, 10kΩ pull-up resistor) Open collector outputs (Load status, Alarm Status, +5V) maximum 30VDC with 1.1V saturation voltage (100mA). When enable is on (active low), the following is ...
INTERFACE Ch3_GO/NG Pin13 Ch7_GO/NG Pin5 Pin14 GND Pin6 Ch4_GO/NG Pin15 Ch8_GO/NG Pin7 GO/NG_Enable Pin8 Connection Type Open collector output maximum 30VDC with 1.1V saturation voltage (100mA). 30 V DC (high) Pass (Go) or SPEC Test: 1.1 V DC (low) Fail (NoGo) USB Interface Connection For USB remote connection, use Connection...
PEL-2000A Series User Manual Q1. The load voltage indicated on the load module is below expected. A1. Ensure the load leads are as short as possible, twisted and use the appropriate wire gauge. Ensure that voltage sense is used, this can help alleviate the voltage drop across the load the leads.
APPENDIX PPENDIX Fuse Replacement 1. Turn off the power at the wall socket and rear Step panel. Remove the power cord. 2. Remove the fuse socket using a minus driver. 3. Replace the fuse in the holder. T3.15A, 250V Rating...
PEL-2000A Series User Manual Firmware Update The PEL-2000A firmware can be easily updated Background using a USB memory stick. File: P2KAXXXX.UPG File Name Copy the firmware file (*.UPG) into the root directory of a USB stick before proceeding with the firmware Note update.
Do not turn the load generator off or remove the USB WARNING memory when the firmware is being read or upgraded. Calibration The PEL-2000A load generator should be Background calibrated at least on a yearly basis. GW Instek does not support End-User calibration. Please see your distributor for calibration details.
PEL-2000A Series User Manual Range Chart PEL-2020A Low Range PEL-2020A High Range 100W Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...
Page 281
APPENDIX PEL-2030A Left Channel PEL-2030A Right Channel Low Range...
Page 282
PEL-2000A Series User Manual PEL-2030A Right Channel High Range 250W PEL-2040A Low Range...
Page 283
APPENDIX PEL-2040A High Range 350W PEL-2041A Low Range...
Page 284
PEL-2000A Series User Manual PEL-2041A High Range 350W...
APPENDIX Default Settings Menu Item Mode: Static A/B Value: Min A CC Mode Rising Slew Rate: Max Falling Slew Rate: Max A Value: Max Ω Mode: Static CR Mode Rising Slew Rate: Max Falling Slew Rate: Max Response: Slow A Value: Max V CV Mode Curr Limit: Max A Range: High...
Page 286
PEL-2000A Series User Manual Repeat: Infinity Times Start of Loop: 001 Step Chan- Seq. Edit - Loop On End Of Seq.: OFF CC Vrange: High Spec Test: Off Entry Mode: Value Chan- Go/NoGo High: Max Low: Min PROG: 01 SEQ: 01...
APPENDIX Specifications PEL-2002A PEL-2004A MODULE SLOTS GENERAL Operating Environment Temperature 0°C to 40°C Altitude Up to 2000m Location Indoor, no direct sunlight, dust free, almost non conductive pollution. Storage Environment Temperature -10°C to 70°C Relative < 80% Humidity Location Indoor Power Supply AC 115V±15%/230V±15% switchable, 50/60Hz, Transient overvoltage on the main supply is 2500V.
Page 288
PEL-2000A Series User Manual PEL-2020A (100Wx2) RANGE High CURRENT 0~2A 0~20A VOLTAGE 1~80V MIN.OPERATING 0.4V at 2A 0.8V at 20A VOLTAGE(dc)Typ.) 0.2V at 1A 0.4V at 10A STATIC MODE CONSTANT CURRENT MODE Operating Range 0~2A 0~20A Setting Range 0~2.04A 0~20.4A Resolution 0.1mA...
Page 290
PEL-2000A Series User Manual PROTECTIVE Over Power Protection Range 1~102W Resolution 0.5W Accuracy ±(2%set + 0.25% F.S.) Over Current Protection Range 0~20.4A Resolution 0.05A Accuracy ±(2%set + 0.25% F.S.) Over Voltage Protection Range 1~81.6V Resolution 0.2V Accuracy ±(2%set + 0.25% F.S.) ≒85℃...
Page 291
APPENDIX PEL-2030A (30W/250W) RANGE High CURRENT 0~5A 0~4A 0~40A VOLTAGE 1~80V MIN.OPERATING 0.8V at 5A 0.4V at 4A 0.8V at 40A VOLTAGE(dc) 0.4V at 2.5A 0.2V at 2A 0.4V at 20A STATIC MODE CONSTANT CURRENT MODE Operating Range 0~5A 0~4A 0~40A Setting Range 0~5.1A...
Page 292
PEL-2000A Series User Manual NOTE : *1 : F.S. = Full scale of H Range CONSTANT POWER MODE Operating Range 1~30W 1~25W 1~250W Setting Range 0~30.6W 0~25.5W 0~255W Resolution 10mV Accuracy ±(0.5%set + ±(0.5%set + 0.5%F.S. 0.5%F.S.) NOTE : *1 : F.S. = Full scale of H Range DYNAMIC MODE T1&T2...
Page 293
APPENDIX MEASUREMENT VOLTAGE READBACK Range 0~16V 0~80V 0~16V 0~80V Resolution 0.32mV 1.6mV 0.32mV 1.6mV Accuracy ±(0.025%set + 0.025% F.S.) CURRENT READBACK Range 0~5A 0~4A 0~40A Resolution 0.1mA 0.08mA 0.8mA Accuracy ±(0.05%set + 0.05% F.S.) POWER READBACK Range 0~30W 0~25W 0~250W Resolution ±(0.1%set + 0.1% ±(0.1%set + 0.1% F.S.
Page 294
PEL-2000A Series User Manual ≒15Ω ≒0.3Ω ≒1.875Ω ≒0.0375Ω Resistance(CR) 500kΩ(Typical) INPUT RESISTANCE (LOAD OFF)
Page 295
APPENDIX PEL-2040A PEL-2041A RANGE High High CURRENT 0~7A 0~70A 0~1A 0~10A VOLTAGE 0~80V 0~500V MIN.OPERATING 0.4V at 7A 0.8V at 70A 0.4V at 1A 0.8V at 10A VOLTAGE(dc)Typ.) 0.2V at 3.5A 0.4V at 35A 0.2V at 0.5A 0.4V at 5A STATIC MODE CONSTANT CURRENT MODE Operating Range...
Page 296
PEL-2000A Series User Manual NOTE : *1 : F.S. = Full scale of H Range DYNAMIC MODE T1&T2 0.025ms~10ms/Res: 1us 0.025ms~10ms/Res: 1us 10ms ~ 30s / Res: 1ms 10ms ~ 30s / Res: 1ms Accuracy 1us / 1ms ± 100ppm 1us / 1ms ±...
Page 297
APPENDIX POWER READBACK Range 0~35W 0~350W 0~35W 0~350W Accuracy ±(0.1%set + 0.1% F.S. ±(0.1%set + 0.1% F.S. NOTE : *1 : Power F.S. = Vrange F.S. x Irange F.S. PROTECTIVE Over Power Protection Range 1~357W 1~357W Resolution 1.75W 1.75W Accuracy ±(2%set + 0.25%F.S.) ±(2%set + 0.25%F.S.) Over Current Protection...
PEL-2000A Series User Manual Dimensions PEL-2002A/PEL-2004A DC Electronic Load PEL-2002A DC Electronic Load DC Electronic Load L 20A / 80V , 100W PEL-2020A PEL-2040A 70A / 80V , 350W 20A / 80V , 100W STATIC/ STATIC/ R / L A / B DYNA.
Page 299
APPENDIX PEL-2020A/PEL-2030A/PEL-2040A/PEL2041A DC Electronic Load 20A / 80V , 100W PEL-2020A 20A / 80V , 100W STATIC/ R / L DYNA. DISPLAY SHORT LOAD V sense V sense 80V DC 80V DC 80V DC 80V DC Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...
PEL-2000A Series User Manual EC Declaration of Conformity GOOD WILL INSTRUMENT CO., LTD. GOOD WILL INSTRUMENT (SUZHOU) CO., LTD. declare that the below mentioned product Type of Product: Programmable Electronic Load Model number: PEL-2004, PEL-2004A, PEL-2002, PEL-2002A. Load module: PEL-2002, PEL-2020A, PEL-2030, PEL-2030A, PEL-2040, PEL-2040A, PEL-2041A, PEL-2041A.
INDEX NDEX Alarm configuration ..... 224 Channel duration time All Chan save/recall settings mode description .. 83 description ......101 Cleaning the instrument ... 7 Baud rate configuration..231 Clear key........19 Brightness & contrast .... 219 Configuration mode Calibration ......279 description ......
Page 302
PEL-2000A Series User Manual EN61010 GPIB ........233 Interface menu ..... 230 measurement category ... 6 RS232 ........231 Pollution degree ...... 8 USB configuration ....234 Enter key ........21 Internal memory save Environment description ......100 operation ........7 Knob configuration ....
Page 303
INDEX Operation......123 Program Sequences ..... 156 R/L keys ....... 124 Programming ....... 156 Shorting ........ 127 Recall default chain ..... 163 Static ........125 Recall default sequence ..160 Lock key ........19 Run Sequence ....... 176 Save chain ......163 Mainframe configuration Save Program chain .....
Page 304
PEL-2000A Series User Manual Constant Voltage + Constant Over voltage mode Current Mode ....71 description ......88 Constant Voltage –Go/NoGo72 Overview ......... 13 Constant Voltage -levels ..70 Display Overview ....23 External Voltage Control ..93 Front panel ......17 File format ......
Page 305
INDEX Save Memory data to USB ... 251 Slave knob Save Preset memory ..... 239 description ......32 Slew rage constant current Save presets to USB ....255 mode description ....66 Save Sequences to USB ..259 Slew rate Constant Resistance Save setup memory ....
Page 306
PEL-2000A Series User Manual Voltage sense terminal ... 31 Wire gauge ......45 Von voltage configuration .. 194 Wire induction ......46 Von voltage mode description90 Wiring procedure ....48 Wire Connections ....45 Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176...