Pin/Signal
Vs1
12 Volt non-isolated
Vs2
3.3 Volt non-isolated
Vs3
5 Volt non-isolated
Geographical Address Inputs
GA [4:0]*, GAP*
System Management
SM [3:0]
RES_BUS+/-
Reserved future use
3.3V Auxiliary power, System
+3.3V_AUX
+/- 12V_AUX
Auxiliary Power Supplies
SYSRESET*
SYS_CON*
Reference Clock 25 MHz or
REF_CLK+/-
Non-Volatile Memory Read
NVMRO
TCK, TMS,
TRST*, TDI, TDO
(wafer 7)
FPGA MGT transmitter
FPGA-TX+/-[7:0]
FPGA-RX+/-[7:0]
FPGA MGT receiver interface
The construction of the
connector wafer is such that
No Pad
there is no circuit pad in this
Table 3: RP0 connector pin description and connection
UM082
Description
0-4, Parity
Connects to 6-pin header (incl GND) and optionally
pulled up to VP_AUX_3P3V if +3.3V_AUX connected.
connections
Management
System Reset
System Slot
100 MHz
Only
JTAG chain through front-panel and on-board JTAG
JTAG Signals
interface
location
www.abaco.com
Connects to
Power Supply Tree
Power Supply Tree
Power Supply Tree
Connects to CPLD.
SM0 and SM1 also connects to CPLD.
Not connected on RTM
If connected, this will pull SM [3:0] up to 3V3.
Not connected
Can be driven from the CPLD
Connects to CPLD and to 4.7k pull-up
Not connected
Connects to the CPLD
connector
Connects to the QTE connector
Connects to the QTE connector
Not connected
r1.3