Warning! If you draw off power and data at the end of a chain, do not
exceed the maximum permitted current for a chain as described in
"Protection from electric shock" on page 5.

Output connections

The VC-Feeder output (OUT) is a 180 mm (7 in.) cable tail with an 8-pin
female IP65 connector that supplies 15 VDC power and data to Martin®
LED-based display devices.
The method for connecting the power + data output from the VC-Feeder is
the same for P3 video and DMX/RDM-controlled systems:
1. Check that the installation is isolated from power.
2. Connect the display device or chain of display devices to the VC-
Feeder OUT connector:
• Follow the instructions under "Input connections: general" on page
13.
• If you are connecting devices to a VC-Feeder that is part of a chain
(i.e. two or more VC-Feeders are linked using the THRU connector),
do not connect devices that will draw more than a combined total of
7.5 A to the OUT connectors in the chain.
• If you are connecting devices to one single VC-Feeder that is not
connected to any other VC-Feeders, you can connect devices that
will draw up to the maximum limit of 7.5 A to that VC-Feeder's OUT
connector.
Connections