LLAC4 Four-Channel, Low-Level AC Conversion Module

5. Program Examples

CR1000 Example Program
'CR1000 Series Datalogger
'LLAC4 Sample Program
'Record 10-minute average wind speed in m/s for:
'1 RM Young 05103-L Wind Monitor Anemometer
'1 RM Young 05106-L Marine Wind Monitor Anemometer
'1 RM Young 05305-L AQ Wind Monitor Anemometer
'1 RM Young 03101-L Wind Sentry Anemometer
'Declare Public Variables
Public RMY05103WS
Public RMY05106WS
Public RMY05305WS
Public RMY03101WS
'Define Data Tables
DataTable (WindSpd,1,-1)
DataInterval (0,10,min,0)
Average (1,RMY05103WS,FP2,False)
Average (1,RMY05106WS,FP2,False)
Average (1,RMY05305WS,FP2,False)
Average (1,RMY03101WS,FP2,False)
EndTable
'Main Program
BeginProg
Scan (1,Sec,0,0)
PulseCount (RMY05103WS,1,15,0,1,0.098,0.0)
4
Using the CR1000, let's measure four different wind speed sensors that produce
low-level AC signals. These will include the RM Young 05103, 05106, 05305,
propeller type anemometers, and RM Young 03101 cup anemometer. Program
examples are provided for both the CR1000 and the CR200(X).
Sensor
05103-L
Sig +
Red
Ref
Black
Drain
Clear
05106-L
Sig +
Red
Ref
Black
Drain
Clear
05305-L
Sig +
Red
Ref
Black
Drain
Clear
03101-L
Sig +
Black
Ref
White
Drain
Clear
Wiring
LLAC4
CR1000
P1
P2
P3
P4
12 V
Red
12 V
G
Black
G
D1
White
C5
D2
Green
C6
D3
Yellow
C7
D4
Blue
C8
G
Clear
G
CR200(X)
Battery +
G
PLL
C1/SDI-12
C2
P_SW
G

Advertisement

Table of Contents
loading

Table of Contents