Mode Description; Off" - Off Mode; Cool" - Cool Mode; Hp" - Heat Pump Mode - Dometic 3314080.000 BLACK Operating Instructions Manual

Comfort control center 2 programmable thermostat
Table of Contents

Advertisement

MODE DESCRIPTION

A. "OFF" - Off Mode
Displays OFF mode in a zone.
B. "COOL" - Cool Mode
In the COOL mode the system will cycle the compressor ON and OFF based on
the room air temperature and the temperature set-point on the CCC 2 thermostat.
When the system calls for cooling there will be a delay of approximately 2 minutes.
During this delay, the hour glass icon will be displayed in the LCD. In auto fan, the
fan will turn ON first followed by the compressor in approximately 15 seconds. In
this mode there are (4) fan speed selections:
LOW: The fan operates continuously at low speed. The compressor cycles ON and
OFF.
MED: The fan operates continuously at medium speed. The compressor cycles ON
and OFF.
HIGH: The fan operates continuously at high speed. The compressor cycles ON
and OFF.
AUTO: When auto fan is selected the fan speed will vary depending on the differ-
ence between the temperature set-point and the room temperature. In auto fan the
compressor and the fan will cycle ON and OFF with the thermostat. The compressor
shuts OFF first followed by the fan in approximately 15 seconds. For more informa-
tion on auto fan, see section, "A. Auto Fan" on page (12).
C. "HP" - Heat Pump Mode
In the HP mode the system will cycle the compressor ON and OFF based on the
room air temperature and the temperature set-point on the CCC 2 thermostat.
When the system calls for heating there will be a delay of approximately 2 minutes.
During this delay, the hour glass icon will be displayed in the LCD. In auto fan, the
compressor will turn ON first followed by the fan in approximately 15 seconds. In
this mode there are (4) fan speed selections:
LOW: The fan operates continuously at low speed. The compressor cycles ON and
OFF.
MED: The fan operates continuously at medium speed. The compressor cycles ON
and OFF.
HIGH: The fan operates continuously at high speed. The compressor cycles ON
and OFF.
AUTO: When auto fan is selected the fan speed will vary depending on the differ-
ence between the temperature set-point and the room temperature. In auto fan the
compressor and fan will cycle ON and OFF with the thermostat. The compressor
shuts OFF first followed by the fan in approximately 15 seconds. For more informa-
tion on auto fan, see section, "A. Auto Fan" on page (12).
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3314080.015 white

Table of Contents