20. Information about radio operation
Radio transmission is performed on a non-exclusive
transmission path, which means that there is a possibility
of interference occurring. Interference can also be caused
by switching operations, electrical motors or defective
electrical devices.
The range of transmission within buildings can differ
greatly from that available in the open air. Besides the
transmitting power and the reception characteristics of the
receiver, environmental factors such as humidity in the vi-
cinity have an important role to play, as do on-site struc-
tural/screening conditions.
eQ-3 Entwicklung GmbH hereby declares that this device
complies with the essential requirements and other
relevant regulations of Directive 1999/5/EC. You can find
the full declaration of conformity at www.eQ-3.de.
Short description:
Supply voltage:
Max. current consumption:
Batteries:
Battery life:
Display:
Receiver frequency:
Typical open air range:
Receiver class:
Method of operation:
Degree of protection:
90
21. Technical characteristics
BC-RT-TRX-CyG-2
3 V
100 mA
2x LR6 batteries
(mignon/AA)
2 years approx.
LCD
868.3 MHz
100 m
SRD Class 2
Type 1
IP20