6.5. Check Before Copy

This option allows to check device real capacity before copying. By default this option is
disabled.
[Setup]
5. Check Before Copy

6.6. Set Slow Out Threshold

This function allows to set up read/write speed threshold for target devices. When the target
device is causing the copy or compare process delay due to its lower read/write speed and
the rest of the devices in the same batch have to wait for it, the Slow Out Threshold strategy
will be applied as the following: the system will stop the copy or compare process for that
particular target device when its read/write speed is below the threshold for continuing
number of seconds based on the setting, and its red LED will flash to give warning. There are
3 settings to set up.
Read: set up the lowest read speed,and options are OFF, 1MB/s~25MB/s. The default
setting is OFF.
Write: set up the lowest write speed, and options are OFF, 1MB/s~25MB/s. The default
setting is OFF.
Duration: set up the period when read or write speed is lower than the threshold for
continuing number of time, and options are 1~20second. The default is 5second.
6.Setup
[Set Slow Out Thresh>]
Write: OFF
ENT
Use▲▼to change option
[Check Before Copy]
ENT
[Setup]
6. Set Slow Out Thresh>
ENT
[Set Slow Out Thresh>]
Duration: 5sec
ENT
Use▲▼to change option
Page 14 of 17
Disable
Use ▲or ▼ to select
[Set Slow Out Thresh>]
Read: OFF
ENT
Use▲▼to change option
Setup Complete!