Webasto Thermo Top E Installation Documentation page 13

Water heater
Hide thumbs Also See for Thermo Top E:
Table of Contents

Advertisement

1
4
5
4
1
8
7
6
1313460C_EN
2
15
3
1
2
16
3
2
3
4
5
17
Citroen C4 Picasso
Model year up to 2009
Produce connections as shown in wiring dia-
gram.
The control takes place before the fan con-
troller connector.
1 Black (sw) wire of IPCU/A
2 Yellow/gray (ge/gr) wire on connector of
fan controller
3 Red (rt) wire of IPCU/E
4 Yellow/gray (ge/gr) wire on connector of
A/C control panel
Model year from 2010
The control takes place at connector 1 from
fan controller.
Produce connections as shown in wiring dia-
gram.
2 White-red (ws/rt) wire of fan motor connec-
tor
3 Black (sw) wire of IPCU/A
4 Red (rt) wire of IPCU/E
5 White-red (ws/rt) wire of A/C control panel
Model year up to 2009
Connect red (rt) wire 5 of IPCU/15 to K3.1/86
according to wiring diagram.
Control changeover of air distribution is car-
ried out at connector 6 from flap motor.
Produce connections as shown in wiring dia-
gram.
1 Black (sw) wire K3.1/30
2 Red (rt) wire to K3.1/87
3 Self-tapping screw on existing hole
4 K3.1 relay
7 White-red (ws/rt) wire of flap motor con-
nector
8 White-red (ws/rt) wire of A/C control panel
Connect-
ing fan
controller
Connect-
ing fan
controller
Installing
K3.1 relay,
connect-
ing air dis-
tribution
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thermo top pThermo top c

Table of Contents