Heat Rejection To Coolant - Kubota WG752 E3 Applications Manual

Table of Contents

Advertisement

6. HEAT REJECTION TO COOLANT

Specific at net intermittent (SAE J1349)
Model
Fuel
Gasoline
WG752
LPG
NOTE
• Heat rejection to cooling water calculating formula
• Ho=Hu·Ne·be·i
Ho : Heat rejection to cooling water
Hu : Fuel lower heating value
Gasoline : 42.7 MJ/kg, 10201 kcal/kg, 18361 BTU/lb
LPG : 47.3 MJ/kg, 11300 kcal/kg, 20339 BTU/lb
NG : 49.5 MJ/kg, 11828 kcal/kg, 21285 BTU/lb
Japanese standard gas
lower heating value : 9699 kcal/m
supply pressure : 0.98 − 2.45 kPa (2.27 − 5.68 oz/inch
Ne : Brake horse power
be : Specific fuel consumption ratio
i : Dispersion ratio to cooling water
Output
kW
Brake horse power
HP
PS
g/kWh
g/HPh
Fuel consumption
g/PSh
lb/HPh
MJ/h
Heat rejection to
kcal/h
cooling water
BTU/h
kW
Brake horse power
HP
PS
g/kWh
g/HPh
Fuel consumption
g/PSh
lb/HPh
MJ/h
Heat rejection to
kcal/h
cooling water
BTU/h
3
(1090 BTU/ft
Engine Speed (min
2000
2400
11.3
13.8
15.1
18.5
15.3
18.8
325
315
243
235
239
231
0.535
0.517
28.85
32.90
6891
7859
27735
31631
10.7
13.1
14.3
17.6
14.5
17.9
301
296
224
221
221
218
0.495
0.487
28.02
32.51
6694
7766
26944
31255
3
)
2
)
1-8
-1
(rpm))
2800
3200
3600
15.6
16.7
17.1
21
22.4
23
21.3
22.7
23.3
323
343
347
241
256
259
238
252
255
0.531
0.564
0.571
37.03
42.32
45.91
8846
10110
10967
35604
40689
44141
14.9
16
16.4
20
21.5
22
20.3
21.8
22.3
306
322
337
228
240
251
225
237
248
0.502
0.53
0.554
37.12
42.16
47.37
8867
10072
11316
35688
40539
45543