2. CAUTION (WG752, WG972)
• Please confirm that the electrical wiring for the igniter and IG coil(s) do not disconnect due to vibration, poor
routing or tension on wire and connector.
If wires become disconnected, catalyst parts may be damaged and very high exhaust gas temperature may result.
• Please confirm that the connecting order of cylinder number of the igniter and IG coil(s) do not make a mistake
at mass-production and maintenance.
If the connecting order is not correct, catalyst parts may be damaged and very high exhaust gas temperature may
result.