Kubota WG752 E3 Applications Manual page 65

Table of Contents

Advertisement

b-
Temperature Measuring Sheet for Small SI Engines
2
Unit model / serial no. :
Engine model :
measuring
* measuring started time :
* measuring stopped time :
(unit = degrees .
1. Atmosphere
2. Engine room
3. Exhaust gas
(together)
4. Engine oil
5. Air intake
6. Cooling air inlet
7. Cooling air outlet
8. Cooling water inlet
R
9. Cooling water outlet
R
10. Air To Boil
***ATB=(x)-(CWIT)+(AT)
11. Overflow volume of
cooling water
12. Fuel
13. Carburetor chamber surface
14. Battery surface
15. surface of starter,
alternator, regulator,
etc.
16. Surface of ignitor, IGcoil
17. Engine rotation
-1
min
(rpm)
note
: 1) Operating conditions : Cooling water / LLC 50%, Thermostat / jacked open.
2) The above judgment (evaluation) standards is to be applied in the max. ambient condition of 40°C (104°F), in case
that the ambient temperature is over 40°C (104°F), it must be judged adding the balance between the actual
temperature and 40°C (104°F) to the judgment standard.
3) Do not run a cooling test if the ambient temperature is below 24°C (75°F) because the large change in air density
and radiation from non cooling system parts give false results.
***Air To Boil (ATB) value must be calculated by using below max. temperature :
LLC 50% with 88.3 kPa (0.9 kgf/cm
special note :
1) The judgment standard > 49°C (120°F) in the above formula { ***ATB = (x) - (CWIT) + (AT) } is KUBOTA's standard.
It may change depending on applications, countries, locations, etc.,
therefor, it is better to judge under the discussion with OEM's referring their own experienced values.
Agreement :
______________________________________________________________________________________________________
______________________________________________________________________________________________________
* If there are specification or structural changes at Customer's product, application must be rechecked and reported.
confirmed
Customer :_____________________
11/jan/01
Product Name :
Engine serial no. :
before
1st
2nd
E/G
start
)
AT
RT
EXT
LOT
T
IAT
T
CAIT
CAOT
T
CWIT
CWOT
ATB
OFQ
FOT
T
T
BRT
STT
ALT
RET
SIT
N
2
or 12.8 psi) pressure cap : (x) = 110°C (230°F)
Distributor :_____________________
checked place at :
Loading condition :
3rd
4th
5th
6th
7th
8th
standard
value of
remarks
evaluation
<75/167
<110/230
(at Continuous)
<120/248
(at Overload)
<45/113
<5/9
(IAT)-(AT)
<40/104
<30/54
(CAOT)-(CAIT)
**radiator cap
<110/230
= 0.9 kgf/cm
>55/131
(at Max.load)
<60/140
<20/68
<20/68
(FOT)-(AT)
<55/131
(CCT)-(AT)
<80/176
<80/176
Low Idling
High Idling
KUBOTA :_____________________
reported by :_____________________