Kubota WG752 E3 Applications Manual page 55

Table of Contents

Advertisement

Model
Fuel
Gasoline
WG972
LPG
DG972
NG
NOTE
• Heat rejection to cooling water calculating formula
• Ho=Hu·Ne·be·i
Ho : Heat rejection to cooling water
Hu : Fuel lower heating value
Gasoline : 42.7 MJ/kg, 10201 kcal/kg, 18361 BTU/lb
LPG : 47.3 MJ/kg, 11300 kcal/kg, 20339 BTU/lb
NG : 49.5 MJ/kg, 11828 kcal/kg, 21285 BTU/lb
Japanese standard gas
lower heating value : 9699 kcal/m
supply pressure : 0.98 − 2.45 kPa (2.27 − 5.68 oz/inch
Ne : Brake horse power
be : Specific fuel consumption ratio
i : Dispersion ratio to cooling water
Output
kW
Brake horse power
HP
PS
g/kWh
g/HPh
Fuel consumption
g/PSh
lb/HPh
MJ/h
Heat rejection to
kcal/h
cooling water
BTU/h
kW
Brake horse power
HP
PS
g/kWh
g/HPh
Fuel consumption
g/PSh
lb/HPh
MJ/h
Heat rejection to
kcal/h
cooling water
BTU/h
kW
Brake horse power
HP
PS
g/kWh
g/HPh
Fuel consumption
g/PSh
lb/HPh
MJ/h
Heat rejection to
kcal/h
cooling water
BTU/h
3
(1090 BTU/ft
Engine Speed (min
2000
2400
14.8
17.8
19.8
23.9
20.1
24.2
404
398
301
297
297
292
0.664
0.654
44.37
47.51
10599
11349
42058
45035
14.7
17.8
19.8
23.8
20.1
24.1
301
287
224
214
221
211
0.494
0.471
36.49
37.80
8717
9031
34589
35837
10.0
13.9
13.4
18.6
13.6
18.9
380
310
283
231
279
228
0.624
0.509
32.73
33.49
7805
7979
30968
31638
3
)
2
)
1-9
-1
(rpm))
2800
3200
3600
20.6
22.2
23.1
27.6
29.8
31.0
28.0
30.2
31.4
371
351
334
276
262
249
272
258
245
0.609
0.577
0.549
54.81
58.90
64.88
13094
14072
15501
51957
55840
61509
20.1
21.2
22.0
26.9
28.5
29.5
27.3
28.9
29.9
286
292
299
213
218
223
210
215
220
0.470
0.480
0.491
45.63
51.87
61.28
10900
12391
14640
43252
49167
58094
16.1
17.4
17.6
21.6
23.3
23.6
21.9
23.7
23.9
298
293
285
222
219
213
219
216
210
0.489
0.483
0.47
39.90
44.67
48.91
9529
10683
11713
37770
42398
46510