Specifications; Unit Specifications - Sanyo KH2442 / CH2442 Service Manual

Split system air conditioner
Hide thumbs Also See for KH2442 / CH2442:
Table of Contents

Advertisement

1-1 Unit Specifications

MODEL No.
POWER SOURCE
PERFORMANCE
Capacity*
Moisture removal (High)
Air circulation (H / M / L)
S.E.E.R. (H.S.P.F.)
ELECTRICAL RATINGS
Voltage rating
Available voltage range
Running amperes
Power input*
Maximum overcurrent protection
FEATURES
Controls
Low ambient control
1
Fan speeds Indoor / Outdoor
Optional Wired Remote Controller (Timer)
Optional Wireless Remote Controller (Timer)
Air deflection
Air filter
Operation sound
Refrigerant control
2
REFRIGERANT PIPING
Limit of piping length
Limit of piping length at shipment
Limit of elevation difference
between the two units
Refrigerant piping
Flare type
DIMENSIONS & WEIGHT
Unit dimensions
3
Net weight
Indoor grille dimensions
PNR-XHS2432
Net weight
Indoor / Outdoor unit
4
Package dimensions
Shipping weight
Shipping volume
Indoor grille
Package dimensions
PNR-XHS2432
Shipping weight
Shipping volume
5
Cooling :
Rating conditions (*)
Heating :
Rating conditions (*)
Low temp conditions (**) : Room temperature 70 F DB / 60 F WB, Ambient temperature 17 F DB / 15 F WB
Indoor Unit
Outdoor Unit
BTU / h
(17 F)**
Pints / h
230 V
cu.ft. / min.
BTU / Wh
VAC
VAC
(17 F)**
Horizontal / Vertical
Indoor - Hi / Me / Lo
dB - A
Outdoor - Hi
dB - A
ft.
(m)
ft.
(m)
ft.
(m)
Narrow pipe
in. (mm)
Wide pipe
in. (mm)
Height
in. (mm)
Width
in. (mm)
Depth
in. (mm)
lbs. (kg)
Height
in. (mm)
Width
in. (mm)
Depth
in. (mm)
lbs. (kg)
Height
in. (mm)
Width
in. (mm)
Depth
in. (mm)
lbs. (kg)
cu.ft. (m
Height
in. (mm)
Width
in. (mm)
Depth
in. (mm)
lbs. (kg)
cu.ft. (m
: Room temperature 80 F DB / 67 F WB, Ambient temperature 95 F DB / 75 F WB
: Room temperature 70 F DB / 60 F WB, Ambient temperature 47 F DB / 43 F WB
230 - 208 V / 1 Phase / 60 Hz
Cooling
24,000
23,400
8.6
8.4
710 / 530 / 450
10.0
10.2
230
208
A
11.2
11.6
W
2,450
2,350
A
Microprocessor
3 and Automatic control / 3 (Auto)
RCS-SH80UG (72-hour ON / OFF)
RCS-SH80UA. WL / RCS-BH80UA. WL (72-hour ON / OFF)
— / Automatic
Washable, easy access, long life fiter (2,500 hr)
Electronic Expansion Control Valve
Outdoor unit is higher than indoor unit: 165 (50)
Outdoor unit is lower than indoor unit: 100 (30)
3 / 4 (19.05)
Indoor unit
12-1/8
(380)
30-9/16
(776)
30-9/16
(776)
49
(22)
3-1/16
(78)
33-27/32
(860)
33-27/32
(860)
11
(5)
13-5/16
(338)
32-7/8
(835)
33-9/32
(845)
57
(26)
3
)
8.4
(0.238)
4-3/32
(104)
37-15/16
(964)
39-11/32
(999)
18
(8)
3
)
3.5
(0.100)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
I - 2

1. Specifications

XH2442
CH2442
Heating
25,000
24,300
16,400
15,800
(7.0)
(7.0)
230
208
187 - 253
11.7
12.3
2,500
2,450
2,150
2,020
25
Built-in 0 F
38 / 35 / 31
53
165 (50)
100 (30)
1 / 4 (6.35)
Outdoor unit
28-15/16
(735)
37-1/32
(940)
13-3/8
(340)
157
(71)
32-17/32
(826)
40
(1,016)
16-3/8
(416)
170
(77)
12.3
(0.349)
SM830082

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents