1-3 Other Component Specifications
(B) Outdoor Unit
MODEL No.
Compressor Motor Magnetic Contactor
Coil rated
Coil resistance (at 68 F)
Contact rated (Main)
Contact rated (Auxiliary)
Power Relay
Coil rated
Coil resistance (at 77 F)
Contact rated
Power Transformer
Rated
Primary
Secondary
Capacity
Coil resistance (at 73 F )
Thermal cut off temperature
Thermistor (Coil sensor) : TH6, 7
Coil resistance
Thermistor (Comp. discharge gas sensor) : TH8
Coil resistance
Solenoid control valve or coil
Solenoid control valve
Solenoid coil
Thermistor (PTC)
Rated
Max. voltage
Max. ampere
Resistance (at 77 F)
k
WHT – WHT : 395.5
F
PBC - 41E - S4
k
14 F : 23.7
23 F : 18.8
32 F : 15.0
41 F : 12.1
k
140 F : 13.8
158 F : 9.7
167 F : 8.2
176 F : 7.0
185 F : 5.9
I - 37
CH4242
FC - 2SUL
240 VAC, 60 Hz
350
10 %
240 VAC, 35 A
240 VAC, 3 A
HH62S
240 VAC, 60 Hz
17.2
220 VAC, 5 A
ATR - I65C
220 VAC, 60 Hz
14 V, 0.4 A
5.6 VA
,
BRN – BRN : 2.19
266
,
PBC - 41E - S36
,
50 F : 9.7
,
68 F : 6.5
,
86 F : 4.4
,
104 F : 3.1
113 F : 2.6
PTC - 51H - S1
,
194 F : 5.1
,
212 F : 3.8
,
230 F : 2.8
,
248 F : 2.2
,
266 F : 1.7
V 389100
LB 59005
TDK – 101YV
400 VAC
11.5 A
+ 30
100
%
– 20
DATA SUBJECT TO CHANGE WITHOUT NOTICE