Sanyo KH2442 / CH2442 Service Manual page 12

Split system air conditioner
Hide thumbs Also See for KH2442 / CH2442:
Table of Contents

Advertisement

1-1 Unit Specifications
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity*
Moisture removal (High)
Air circulation (H / M / L)
External Static Pressure
S.E.E.R. (H.S.P.F.)
ELECTRICAL RATINGS
Voltage rating
Available voltage range
Running amperes
Power input*
Maximum overcurrent protection
FEATURES
Controls
1
Low ambient control
Fan speeds Indoor / Outdoor
Optional Wired Remote Controller (Timer)
Optional Wireless Remote Controller (Timer)
Air deflection
Air filter
Operation sound
2
Refrigerant control
REFRIGERANT PIPING
Limit of piping length
Limit of piping length at shipment
Limit of elevation difference
between the two units
Refrigerant piping
Flare type
DIMENSIONS & WEIGHT
3
Unit dimensions
Net weight
Package dimensions
Shipping weight
4
Shipping volume
Cooling :
Rating conditions (*)
Heating :
Rating conditions (*)
Low temp conditions (**) : Room temperature 70 F DB / 60 F WB, Ambient temperature 17 F DB / 15 F WB
5
Indoor Unit
Outdoor Unit
BTU / h
(17 F)**
Pints / h
230 V
cu.ft. / min.
in.Aq (Pa)
BTU / Wh
VAC
VAC
(17 F)**
Horizontal / Vertical
Indoor - Hi / Me / Lo
dB - A
Outdoor - Hi
dB - A
ft.
(m)
ft.
(m)
ft.
(m)
Narrow pipe
in. (mm)
Wide pipe
in. (mm)
Height
in. (mm)
Width
in. (mm)
Depth
in. (mm)
ibs. (kg)
Height
in. (mm)
Width
in. (mm)
Depth
in. (mm)
lbs. (kg)
cu.ft. (m
: Room temperature 80 F DB / 67 F WB, Ambient temperature 95 F DB / 75 F WB
: Room temperature 70 F DB / 60 F WB, Ambient temperature 47 F DB / 43 F WB
230 - 208 V / 1 Phase / 60 Hz
Cooling
24,000
23,400
8.4
7.7
670 / 530 / 460
0.2 (49) : at shipment / 0.4 (100) : using jumper cable
10.0
10.0
230
208
A
11.5
12.1
W
2,550
2,480
A
Microprocessor
3 and Automatic control / 3 (Auto)
RCS-SH80UG (72-hour ON / OFF)
RCS-BH80UA. WL (72-hour ON / OFF)
34 / 30 / 27 : at shipment / 38 / 34 / 30 : using jumper cable
Electronic Expansion Valve
Outdoor unit is higher than indoor unit: 165 (50)
Outdoor unit is lower than indoor unit: 100 (30)
3 / 4 (19.05)
Indoor unit
12-7/32
(310)
39-3/8
(1,000)
24-13/16
(630)
1-1/4
(32)
14-3/32
(358)
46-7/8
(1,191)
30-13/16
(1,191)
82
(37)
3
)
11.8
(0.334)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
I - 8
1. Specifications
UH2442
CH2442
Heating
27,000
26,500
16,200
15,500
(7.0)
(7.0)
230
208
187 - 253
12.0
12.5
2,650
2,550
2,080
1,960
25
Built-in 0 F
— / —
Optional
53
165 (50)
100 (30)
1 / 4 (6.35)
Outdoor unit
28-15/16
(735)
37-1/32
(940)
13-3/8
(340)
32-17/32
(826)
40
(1,016)
16-3/8
(416)
157
(71)
170
(77)
12.3
(0.349)
SM830082

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents