Automatic Fan Speed (Indoor Unit); (A)Cooling; (B)Heating - Sanyo KH2442 / CH2442 Service Manual

Split system air conditioner
Hide thumbs Also See for KH2442 / CH2442:
Table of Contents

Advertisement

2-3 Automatic Fan Speed (Indoor Unit)

By pressing the FAN SPEED button on the remote controller, the fan speed can be set at
one of four steps: AUTO., HI., MED., or LO. When set at AUTO. the indoor unit fan speed
will be automatically adjusted to the room temperature as the two charts shown below.
(A) Cooling
When the fan speed changes, it keeps the speed step for at least 3 minutes, even if the
temperature changes to another speed step during the time.
(B) Heating
When the fan speed changes, it keeps the speed step for at least 1 minute, even if the
temperature changes to another speed step during the time.
ROOM TEMP.
(deg)
+3
+2
+1
SET TEMP.
INDOOR FAN
SPEED
H
M
H
: High
L : Low
M
: Middle
Chart Explanations and notes