Sanyo KH2442 / CH2442 Service Manual page 189

Split system air conditioner
Hide thumbs Also See for KH2442 / CH2442:
Table of Contents

Advertisement

5 5 5 5 5
Motor capacitor ............ Both in indoor and outdoor unit
• Remove the lead wires from the capacitor terminals, and then place a probe on the capacitor
terminals as shown in Fig. IV-19. Observe the deflection of the pointer, setting the resistanc
measuring range of the multimeter to the maximum value.
• The capacitor is "good" if the pointer bounces to a great extent and then gradually returns to
its original position.
NOTE
The range of deflection and the deflection time
differ according to the capacity of the capacitor.
6 6 6 6 6
Continuity of fuse on P.C.B. Ass'y
Check for continuity using a multimeter
as shown in Fig. IV-20.
NOTE
Method Used to Replace Fuse on PCB Ass'y
1. Remove the PCB Ass'y from the electrical compo-
nent box.
2. Remove the fuse from PCB Ass'y using pliers while
heating the soldered leads on the back side of the
PCB Ass'y with a soldering iron (30W or 60W).
(Fig. IV-21)
3. For replacement, insert a fuse of the same rating to
the intended position and solder it.
(Allow time to radiate heat during soldering so that
the fuse does not melt.)
When replacing the fuse, be
sure not to break down the
CAUTION
varistor.
Compressor motor
capacitor
Pliers
IV - 33
4. Service procedures
Multimeter
Fan motor
capacitor
1041_X_S
Fig. IV-19
Fuse
1042_X_S
Fig. IV-20
Soldering iron
PCB Ass'y
Fuse
Varistor
1043_X_S
Fig. IV-21
SM830082
SM830082
Section
1
2
3
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents