WARNING
If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Immediately call your gas supplier from a neighbor's phone. Follow the gas
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Flammable materials
falling objects
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
NOTICE
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
PVHEX58-300 power vent is approved for use with Montigo R320, R320-ST, R420,
R420-ST, and RP620.
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
XG0517
NOTICE
PVHEX58-300 &
PVHEX510-300
5/8 and 5/10
External Wall
Power Vent
NOTICE
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
NOTICE
PVHEX510-300 power vent is approved for use with Montigo R520, R520-ST,
NOTICE
R620-ST, R720, and R820.
This power vent is approved for use with Montigo fireplaces only and is certified to
ANSI Z21.50 / CSA 2.22 vented gas fireplace standard along with the fireplace.
NOTICE
PVVEX510-300 power vent is approved for use with Montigo R520, R520-ST,
R620-ST, R720, and R820.
070714

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVHEX58-300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Montigo PVHEX58-300

  • Page 1 PVVEX510-300 power vent is approved for use with Montigo R520, R520-ST, PVHEX58-300 power vent is approved for use with Montigo R320, R320-ST, R420, R620-ST, R720, and R820. R420-ST, and RP620. Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248 XG0517 070714 NOTICE...
  • Page 2: Safety Alert Key

    PVHEX58-300 Horizontal Power Vent System Safety Alert Key Introduction Specifications Pipe Dimensions PVHEX58-300 ... 5"/8" Pipe Dimensions PVHEX510-300 ..5"/10" Maximum Airflow: ......300 CFM Speed: .......... 2700 RPM Power: ..........Connect to fireplace control box ..........Refer to fireplace rating plate...
  • Page 3: Product Dimensions

    13" " 13" " " " PVHEX58-300 5" 8" Rear View PVHEX10-300 Side View " " 10" Power Head Framing Kit Electrical Box Vent Retainer Figure 1. PVHEX58-300 & PVHEX510-300 (Tolerance ± ⅛") [mm] Page 3 XG0517 - 070714 "...
  • Page 4: Installation

    PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Installation Installing the Power vent Unpacking the Power vent Step 1: Unscrew Power Head from rough in Box by unscrewing four screws. " Framing Figure 2a. Unscrewing four screws " Wall board Rough in box Figure 2.
  • Page 5 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Installation Step 5: Remove electrical cover. Step 3: Screw rough in box to wall. Figure 2f. Step 6: Remove two screws securing the strain relief plate. Figure 2d. Step 4: Remove six screws securing the electrical cover.
  • Page 6 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Installation Step 11: Secure the electrical cover back down with the six screws Step 8: Take the electrical harness (EPVH-10-100) that will commu- making sure the control cable curls up safely. nicate with the Power vent and pass the cable through the slot in the rough box.
  • Page 7 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Installation Step 13: Slip the Vent Support Band over the vent so that it sits flush Step 15: Push the power head onto the vent. Make sure the power cable for the power head does not get pinched or caught.
  • Page 8: Wiring Installation

    PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Power Vent Wiring Installation Wiring Diagram. 6 PIN MOLEX CONNECTOR GREEN BLUE BL CK BROWN BL CK WHITE KEY WAY Figure 3. Power Vent Wiring Diagram Wiring Installation Conduit & Wiring clearances Connect the power vent harness as outlined. Connect the wiring to the fireplace as oulined in the schematic shown in figure 4.
  • Page 9 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Installation PVHEX58 300 V VENTER TERMINAL X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations US Installations Canadian Installations US Installations A= Clearance above grade, veranda, 12 in (30 cm) 12 in (30 cm) J= Clearance to nonmechanical air 6in (15 cm) for appliances <...
  • Page 10: Capacitor Replacement

    PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Service Capacitor Replacement Step 1: Turn off power and gas. Step 4: Cut Brown Wire From Motor. REC1254 Figure 5a. Figure 5d. Step 2: Remove 8 screws securing the outer cover of the power head.
  • Page 11 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Service Step 6: Remove ground screw that secures the ground wire and Step 8: Using the large bell connector, connect the white fiber wire capacitor bracket to the motor. Note: Keep this screw for later use.
  • Page 12 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Service Step 12: Secure outer cover with supplied 8 screws. Step 10: Using three supplied zap straps, neatly secure wiring. Make sure no wires can get caught in the motor or pinched. 8 fasteners (4 oposite side)
  • Page 13 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Service Motor and Capacitor Replacement Step 3: Cut 3 zap straps securing wiring. Step 1: Turn off power and gas. REC1255 Figure 6c. Step 4: Cut brown wire from motor. Figure 6a. Step 2: Remove 8 screws securing the outer cover of the power head.
  • Page 14 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Service Step 8: Lift motor assembly out. Step 6: Cut the black fiber wire from power cable. Figure 6e. Figure 6g. Image 40 Step 7: Remove eight screws securing the motor plate to power Step 9: Put new motor assembly in.
  • Page 15 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Service Step 12: Using a supplied small bell connector, connect the black Step 10: Secure motor plate with supplied eight screws. fiber wire from the power cable to the blue wire from the motor.
  • Page 16 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Service Step 14: Using the other supplied small bell connector, connect the Step 16: Check operation and rotation. Motor should spin counter brown wire from the motor to the black wire from the capacitor.
  • Page 17 PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Notes Page 17 XG0518 - 070714...
  • Page 18: Appendix A: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 19: Appendix B: State Of Massachusetts

    PVHEX58-300 & PVHEX510-300 Horizontal Power Vent Appendix Appendix B: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows:...
  • Page 20 PVHEX58-300 & PVHEX510-300 Power Vent Termination Ferndale, Washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0517 - 050514...

This manual is also suitable for:

Pvhex510-300

Table of Contents