General Data - 25 Ton Standard Efficiency - Trane Voyager Manual

Product
Table of Contents

Advertisement

Table 14-1
General Data
Cooling Performance
1
Gross Cooling Capacity
EER
2
Nominal CFM / ARI Rated CFM
ARI Net Cooling Capacity
3
Integrated Part Load Value
System Power (KW)
Heating Performance
4
Heating Models
Heating Input (Btuh)
1st Stage
Heating Output (Btuh)
1st Stage
5
AFUE (%)
Downflow/Horizontal
Steady State Efficiency (%)
No. Burners
No. Stages
Gas Connection Pipe Size (in.)
Compressor
No./Type
Sound Rating (BELS)
6
Outdoor Coil - Type
Tube Size (in.) OD
Face Area (sq ft)
Rows/FPI
Indoor Coil - Type
Tube Size (in.)
Face Area (sq ft)
Rows/FPI
Refrigerant Control
Drain Connection No./Size (in.)
Outdoor Fan - Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
CFM
No. Motors/HP
Motor RPM
Indoor Fan - Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
No. Motors
Motor HP (Standard/Oversized)
Motor RPM (Standard/Oversized)
Motor Frame Size (Standard/Oversized)
Filters - Type/Furnished?
(No.) Size Recommended
7
Refrigerant Charge (Lbs of R-22)
NOTES
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and
includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Rated in accordance with ARI Standard 210/240 or 360.
2. EER is rated at ARI conditions and in accordance with ARI Standard 210/240 or 360.
3. Integrated Part Load Value is based on ARI Standard 210/240 or 360. Units are rated at 80° F ambient, 80° F entering dry bulb, and 67° F entering wet bulb at ARI rated cfm.
4. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings
shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
5. AFUE is rated in accordance with DOE test procedures.
6. Sound Rating is rated in accordance with ARI Standard 270 or 370.
7. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
8. Horizontal models have 8 - 20 x 25 x 2 filters.
Indicates both downflow and horizontal units.
General
Data
25 Ton Downflow and Horizontal Units
YC 300B3,B4,BWL
YC 300B3,B4,BWH
290,000
9.3
10,000 / 8,750
272,000
9.60
29.10
Low
250,000
400,000
175,000
300,000
203,000
324,000
142,000
243,000
80.2/81.0
79.8/79.7
81.4/81.0
80.8/81.0
1
2
1/2
2/Trane 3-D® Scroll
9.4
Hi-Performance
.375
36.43
2/16
Hi-Performance
.375
26.00
3/15
Short Orifice
1/1.00 NPT
Propeller
2/28
Direct/1
16,700
2/1.0
1,125
FC Centrifugal
1/18 X 18
Belt/1
1
7.5/NA
3470/NA
184T/NA
Throwaway/Yes
(4) 20 X 20 X 2
(4) 20 X 25 X 2
17.0/Circuit
14
25 Ton
Standard Efficiency
High
3/4