The Compressor; Attaching Air Fittings And Compressor Hook Up - Te Pari Racewell HD3 Installation And Operation Manual

Sheep handlers
Hide thumbs Also See for Racewell HD3:
Table of Contents

Advertisement

Racewell HD

THE COMPRESSOR

We recommend a 12cfm belt driven compressor, if the compressor is too small the
Racewell will run slowly and may not operate properly
The compressor does not need to be close to the Racewell in fact having it at some
distance reduces noise levels in the working area It is important to run compressors in a
well ventilated area as close as possible to a main supply near a switchboard - this avoids
the use of leads which can affect the power input From time to time the oil level on the
dipstick should be checked and the water drained from the air reservoir
Please Note: When turning the compressor on or off use the switch on the compressor.
Do not turn on or off at the power source switch.
This applies to all compressors, because air is not discharged, the compressor is being asked to start
under load and this can burn out its capacitor
ATTACHING THE AIR FITTINGS AND COMPRESSOR HOOK UP
Pipe the air to the compressor to the unit via standard 15mm (1/2 inch) alkathene water
line We have some units working with the compressor up to 2kms from the work site
From your
Compressor
power source and turn the power source on, then using the switch on the compressor turn
the compressor on Always turn the compressor on or off at the compressor, not the wall
The 3 pin socket on the power pack situated under the sheep unit can now be connected
to the power source The airline from the compressor (female end) can now be plugged
into the male fitting on the underside of the sheep unit This is on the same side as the
power pack was plugged in It is just inside the frame, toward the back
Using the Hoist Switch on the dashboard or the manual hoist lever under the floor section,
carefully tilt the unit Disconnect the air from the sheep unit You now have access under
the unit Non-tilt options are tilted for access by hand, just lift up until the weight is taken
on the safety chain
Te Pari - www.tepari.com - FREEPHONE 0800 837 274
To your
Racewell
1 metre
(approx)
Ball or tap valve
SHEEP HANDLING SYSTEMS
If your compressor is situated some
distance from your Racewell we
recommend the airline configuration
shown here
This provides a purge tap or ball valve
so that condensation can be periodically
removed from the air system
Assemble the airline and connect to the
compressor Plug the compressor into a
6
HD3 Sheep Handler Installation Manual
1214-V1