Fan

If a fan fails, the remaining fans increase to full speed, the information LED on the control
panel illuminates, and an email alert is sent to the system administrator. Replace a failed fan
as soon as possible. Remove the top chassis cover while the system is still running to
determine which fan failed.
Fans are hot-swappable, so you do not need to power down your unit when replacing a fan.
To replace a fan:
1.
Remove the chassis cover.
For more information, see
2.
Press the tabs on the sides of the fan to unlock and remove the fan and its housing.
The fan's power connection automatically detaches.
3.
Replace the failed fan with an identical fan.
You hear a click when the fan is fully installed and the power connections are made. If the
system power is on, the hot-plug feature causes the fan to start immediately upon being
connected to its header on the mainboard.