System Features And Specifications; Smart Uv Features; System Specifications; Sizing Chart - Pentair SMART UV EU18-U Installation And User Manual

Uv disinfection sterilizer
Hide thumbs Also See for SMART UV EU18-U:
Table of Contents

Advertisement

6

SYSTEM FEATURES AND SPECIFICATIONS

All SMART UV
Systems UV Sterilizer models are
®
packaged complete, with all necessary components
that are required to operate the unit. When unpacking,
it is recommended to perform a complete component
inventory to ensure everything is accounted for and
hasn't been damaged.
The serial number of your UV unit is located on a
small white label near the electrical end of the unit's
vessel.
The model number of your UV unit can be found in
two locations:
1. On the bar code label at the end of the box.
2. On the label placed in the middle of the UV Vessel,
with a hole punch indicating the model number.

System Specifications

Max Flow
Model
Rate @ 30
No.
mJ/cm2
EU18-U
6 GPM
EU25-U
9.5 GPM
EU40
15.5 GPM
EU65P
26 GPM
E50S
26 GPM
E80S
45 GPM
E120S
64 GPM
E150S
100 GPM
E150S-2
100 GPM
SMART UV® UV DISINFECTION STERILIZER Installation and User's Guide
Lamp
Amperes
Wattage
(A)
18
0.34-0.17
25
0.40-0.20
40
0.44-0.22
65
0.46-0.23
50
1.15/0.57
80
1.15/0.57
120
1.15/0.57
150
1.82
150
0.81

SMART UV Features

Our GPH T-5 and T-6 low pressure mercury vapor
germicidal amps, convert approximately 30% of their
electrical input watts into UV-C output watts within
the germicidal action spectrum (meaning 30% of
electricity used is converted into useful germicidal
UV light), the highest UV-C output conversion among
all UV lamps.
• UL listed for indoor and outdoor use, fresh and salt
water use.
• Long lasting GPH/T5 and GPH/T6 UV lamps (9,000
hours to 80% efficiency).
• Protective Quartz Sleeve (maximizes UV lamp
output and safety)
• Watertight Design
• Easy-to-Remove Power Assembly
• Remote Power Supply
• UV Resistant High Density Plastic UV Vessel
• Utilizes the UV lamp to its maximum potential
(maximum UV exposure)
• Non-UV Transmitting Clear Lamp Viewing Ports
UV-C
Dimensions
Output
H x W
Watts
(Inches)
5.4
23" X 4"
7.5
29" X 4"
12
44" X 4"
19.5
71" X 4"
15
28" x 5.75"
26
43" x 5.75"
36
56" x 5.75"
47
70" x 5.75"
47
70" x 5.75"
Input Voltage
Port
(50/60 Hz)
Connection
120-240 VAC
120-240 VAC
1.5" Union/
1" Barb
120-240 VAC
120-240 VAC
120-240 VAC
120-240 VAC
120-240 VAC
2" Union
120 VAC
240 VAC