Long range lantern adjustable from 4-12nm+ (44 pages)
Summary of Contents for Sealite SL-C310
Page 1
SL-C310, SL-C410 & SL-C415 Marine Lanterns Installation & Service Manual Version 4.2...
Page 2
Version No. Description Date Author Approved Manual Launch: SL-C410 added & IR Control March 2012 C. Procter Addition of Configuration Settings Information April 2012 S. Turner Configuration Settings update April 2012 C. Procter Addition of LUX Table April 2012 J. Dore Update to Max Intensities &...
As a commitment to producing the highest quality products for our customers, Sealite has been independently certified as complying with the requirements of ISO9001:2008 quality management system. Sealite lanterns comply with requirements of the US Coast Guard in 33 CFR part 66 for Private Aids To Navigation.
fl ick of a switch. It can also be fi tted with an optional external charging port for charging the battery while it is stored for extended periods. The SL-C310. SL-C410 and SL-C415 models are fi tted with a GPS unit to synchronise fl ashing lights over any distance.
SL-C310, SL-C410 & SL-C415 3–5NM+ Marine Lanterns SL-C410 & SL-C415 Models SL-C410 Model Latest products and information available at www.sealite.com...
Page 9
SL-C310, SL-C410 & SL-C415 3–5NM+ Marine Lanterns SL-C415 Model Latest products and information available at www.sealite.com...
7. The unit is now ready for normal operation, once placed in darkness. 8. Close the light head, and replace 4 socket head screws. Sealite, recommend that the Light Head be tightened onto the Solar Chassis Base using a general purpose “Grip Tool”, similar in shape to a Screwdriver, however with the appropriate Hex Key Head fitted.
100% setting and the range by 20% - 40% depending on the maximum intensity. Refer to Sealite power calculator to confirm reduced range. This setting may be used to adjust the current draw of the light to local sunlight conditions.
A comprehensive list of available flash codes is listed on in the ‘Flash Codes’ section of this manual. Example: SWITCH FLASH CODE FL 3 S Note – if setting the lantern to a demanding duty-cycle such as steady-on, the power setting must be reduced to ensure reliable operation Latest products and information available at www.sealite.com...
SL-C310, SL-C410 & SL-C415 3–5NM+ Marine Lanterns Flash Codes Sealite marine lanterns may be set to any of 256 IALA recommended flash settings which are user-adjustable onsite without the need for external devices. SEALITE® code reference is listed by number of flashes For the latest version of this document visit www.sealite.com...
Page 14
FL 5 S FL 15 S 14.0 FL 5 S LFL 15 S 11.0 FL 5 S OC 15 S FL 5 S LFL 20 S 18.0 FL 5 S FL 26 S 25.0 Latest products and information available at www.sealite.com...
Page 15
FL (2) 12 S 10.0 FL (2) 12 S FL (2) 15 S 11.0 FL (2) 15 S 11.0 Q (2) 15 S 13.8 FL (2) 20 S 15.0 FL (2) 25 S 22.0 Latest products and information available at www.sealite.com...
Page 16
VQ (3) 15 S 13.7 FL (2) + LFL 16 S FL (3) 20 S 12.5 FL (3) 20 S 15.5 FL (3) 20 S 12.0 FL (3) 20 S 15.2 FL (3) 20 S 15.0 Latest products and information available at www.sealite.com...
Page 17
FL (5) 20 S 11.2 FL (5) 20 S 11.0 SWITCH Controller FLASH CODE OFF ON OFF ON OFF ON OFF ON OFF ON Q (6) 10 S FL (6) 15 S FL (6) 15 S Latest products and information available at www.sealite.com...
Page 18
MO (A) 10 S MO (D) 10 S MO (A) 15 S 11.0 MO (U) 15 S 11.8 MO (U) 15 S 10.7 MO (U) 15 S 10.1 MO (B) 15 S 10.5 Latest products and information available at www.sealite.com...
3–5NM+ Marine Lanterns GPS Synchronisation The SL-C310/410/415 models come with GPS fitted as standard, and provide the user with the ability to install independently operating lanterns that all flash in synchronisation. No additional power supplies, aerials or control systems are required, and with its microprocessor- based system, the GPS option is specifically designed to provide maximum reliability and performance over a wide range of environmental conditions.
There is one red and one yellow status LED. The red status LED is used to indicate the health of the lantern’s power system. The yellow status LED is used to indicate the operational status of the lantern. These indicator LED’s can be viewed at the base of the lens. Latest products and information available at www.sealite.com...
Page 21
SL-C310, SL-C410 & SL-C415 3–5NM+ Marine Lanterns All Sealite boards are fitted with two Indicator LED’s. These are positioned near the Flash Code Rotary Switches. Use the table below to help determine operational status. Yellow LED Lantern Status Lantern Comment...
Sealite IR Controller / Universal Remote Compatibility If you lose your Sealite IR Controller, the following Universal Remote Controller has been tested for compatibility: RCA Type RCR312WR programmed for Phillips TV Type Code 10054...
For example if the current Flash Code is set to 51 via the AB switches, the lamp will flash number 081. For a flash code set to 01, the lamp will flash 001. Latest products and information available at www.sealite.com...
Standby Mode: manually forces the lantern to turn off, disables the GPS but with access to daylight it will still charge the battery pack. Read Operation Mode Set Operation Mode to Always on Set Operation Mode to Standby Mode Set Operation Mode to Dusk to dawn Latest products and information available at www.sealite.com...
This sets the ambient light level to be lower than the default 100 lux. The light will turn on when its surroundings are darker. The light responds by acknowledgement with a long flash. Latest products and information available at www.sealite.com...
IR Remote Control, the lamp will flash 49 which is the corresponding number for switches A=3, B=1. Use the IR Remote Control to read the current lamp intensity setting and flash code. Latest products and information available at www.sealite.com...
Mode and depending on the current calendar month setting will either Hibernate or enter Dusk-to- Dawn mode. By default, Hibernation mode is disabled. Note you can only use this command once a valid hibernation start & end date has been stored in the lantern. Latest products and information available at www.sealite.com...
Page 28
In this example, we want the lantern to hibernate each year from Dec 10th, through to February 15th, and the lantern is located inside a storage warehouse. The required key sequence is: Command IR Controller Key Press Store the Hibernation Date Range Enable Hibernation Latest products and information available at www.sealite.com...
By pressing the following key sequence the lantern will enter Storage Mode: The lantern will leave storage mode when exposed to daylight or if the power switch is turned OFF and ON again. Latest products and information available at www.sealite.com...
SMS text messages to designated cellular telephone numbers. users can also have alarms and reports sent to designated email addresses. Please contact Sealite for further information and instructions. SL-C410 model shown with optional GSM Module Latest products and information available at www.sealite.com...
To ensure waterproofing of the unit, make sure that there is an even seal. Long Term Battery Storage If the SL-C310/410/415 is to be placed in storage for an extended period please follow the below information. The sealed lead acid batteries inside the lights must always be stored in a fully charged state.
3–5NM+ Marine Lanterns Solar Panel Replacement The SL-C310/410/415 are built around an internal aluminium chassis. The solar panels can be user- replaced in the unlikely event that one is broken or damaged during the product’s life. Follow the steps below or contact support@sealite.com for more details.
Applying a higher Torque setting is not recommended and may void warranty. If in doubt, please contact your local Sealite representative. Use the label to ensure correct location SL10 AMP Regulator shown when of wires during assembly correctly fitted Latest products and information available at www.sealite.com...
• Expose lantern to direct sunlight and monitor operation for entire night. several days. Sealite products typically require 2.5 hours of direct sunlight per day to retain full autonomy. From a discharged state, the lantern may require several days of operational conditions to ‘cycle’...
SL-C310, SL-C410 & SL-C415 3–5NM+ Marine Lanterns Sealite LED Light Warranty V2.2 Please refer to www.sealite.com Latest products and information available at www.sealite.com...
Page 36
SL-C310, SL-C410 & SL-C415 3–5NM+ Marine Lanterns Notes Latest products and information available at www.sealite.com...
Need help?
Do you have a question about the SL-C310 and is the answer not in the manual?
Questions and answers