Assembly
5.2 Lift the machine to where it will be installed, and position it
See also
Draining condensation (Page 70)
5.2.9

Draining condensation

Under the following conditions it is possible that condensate may accumulate within the
machine:
● Wide fluctuations in the ambient temperature, such as direct sunshine combined with high
● Intermittent operation or load fluctuations during operation
Depending on the type of installation, the water drainage holes are located at the bottom:
Allow the condensation water to discharge for vertical placement
In the DE bearing shield, water drain holes are located in the area of the mounting feet or
opposite the regreasing system. They are sealed with screw plugs.
Figure 5-2
Condensation water drain for vertical mounting
70
atmospheric humidity
NOTICE
Damage due to condensate
If the stator winding is damp, its insulation resistance will be reduced. This can result in
voltage flashovers, which can destroy the winding. Condensate can also cause rust to
form within the machine.
Ensure that condensate can drain away.