Maintenance
9.1 Inspection and maintenance
9.1.7

Assessing the roller bearings

To assess the roller bearings, it is generally not necessary to dismantle the machines. The
motor only has to be dismantled if the bearings are to be replaced.
The state of a roller bearing can be assessed by analyzing the bearing vibration. The measured
values provide an indication and can be assessed by specialists. Contact the Service Center.
Overheating of the rolling bearings
If the roller bearings are not regularly regreased, local overheating may be possible, and, as
a consequence, an explosion in an explosive atmosphere. This can result in death, serious
injury or material damage.
● Regrease the roller bearings regularly according to the lubrication plate.
● Implement bearing temperature monitoring if not yet in existence.
9.1.8

Roller bearings with automatic regreasing system

The roller bearings are supplied with new grease by the regreasing system.
● Replace the grease cartridge timely.
● Observe the operating instructions for the regreasing system when replacing the grease
See also
Interlock circuit for the automatic regreasing system (option) (Page 41)
NOTICE
Unsuitable greases
Only use the grease that is specified on the lubricant plate.
9.1.9

Regreasing intervals and types of grease for operating roller bearings

The specified grease data applies to the data specified on the rating plate and for high-quality
grease in accordance with the specifications in these operating instructions. Because these
greases exceed significantly the requirements according to DIN 51825 and ISO 6743‑9, they
permit the specified relubrication intervals.
Initial lubrication
The grease specified on the lubricant plate is selected according to the operating conditions
known at the time of ordering and should be used for initial lubrication.
138
WARNING
cartridges.
SIMOTICS FD 1MH1
Operating Instructions 08/2017