System 3000
Blind timer and timer Bluetooth
Priorities for the LED display:
- Red LED before green or orange LED
- Blue LED before red LED
3
Function
Intended use
–
Manual and time-controlled operation of e.g. Venetian blinds, shutters, awnings, lighting or
fans
–
Operation and programming with mobile end device (smartphone or tablet) via Bluetooth
with app
–
Operation of switching, dimming or Venetian blind insert or 3-wire extension of System
3000
Product characteristics
Functions directly on the cover
–
Operation of blinds/shutters and lighting
–
Activating / deactivating the disabling function
–
Activating / deactivating automatic operation
–
Running time and ventilation position of the blind/shutter can be saved
–
Switch-on brightness or switch on to last brightness with dimming insert can be saved
–
Night mode
Functions via Bluetooth app
–
Operation of blinds/shutters and lighting with status feedback
–
Display of current blind/shutter position, dimming position or switching state
–
Programming of up to 40 individual switching times
–
Venetian blind and slat positions or switching and dimming values can be saved at any
switching time
–
Possible to copy switching times from other devices
–
Switching at sunrise and/or before sunset (Astro function)
–
Astro time through position fixing
–
Astro time shift can be set for each switching time
–
Automatic summer/winter time changeover, can be switched off
–
Random function
–
Automatic date and time update when connecting with smartphone
–
Code request for protection for time programs and configuration possible
–
Save a ventilation position, blind/shutter running time, slat change-over time and change-
over-time for direction change
–
Switch to inverse operation for Venetian blind inserts possible
–
Maximum brightness and minimum brightness for dimming insert can be set
–
Sun protection and twilight functions are possible via optional brightness sensor
Behaviour after a mains voltage failure
Voltage failure less than power reserve
–
All data and settings are preserved
–
Missed switching times are not performed later
Voltage failure greater than power reserve
–
The blue LED flashes three times repeatedly until the time is automatically updated when
connected with the app
–
No switching operations are executed
–
Switching times are preserved
32598102