Performance Data

GSZ140181K* + ARUF25B14** + TXV
Conditions: 80 °F IBD, 67 °F IWB @ 610 CFM
Outdoor
Total
Sensible
Tem. ° F.
BTU/h
BTU/h
75
18,900
13,986
80
18,650
14,077
85
18,400
14,168
90
18,000
14,036
95
17,600
13,904
100
17,100
13,675
105
16,600
13,446
110
16,150
13,474
115
15,700
13,502
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
17,000
13,600
GSZ140241K* + ARUF25B14** + TXV
Conditions: 80 °F IBD, 67 °F IWB @ 870 CFM
Outdoor
Total
Sensible
Tem. ° F.
BTU/h
BTU/h
75
25,100
19,076
80
25,400
19,093
85
24,500
19,110
90
24,550
18,915
95
23,400
18,720
100
23,350
18,532
105
22,100
18,343
110
22,050
18,368
115
20,900
18,392
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
22,600
18,532
GSZ140301K* + ARUF29B14** + TXV
Conditions: 80 °F IBD, 67 °F IWB @ 870 CFM
Outdoor
Total
Sensible
Tem. ° F.
BTU/h
BTU/h
75
29,600
20,720
80
29,250
20,764
85
28,900
20,808
90
28,250
20,616
95
27,600
20,424
100
26,850
20,130
105
26,100
19,836
110
25,400
19,922
115
24,700
20,007
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
26,600
19,950
32
Latent
Total
BTU/h
Watts
4,914
1,180
4,573
1,245
4,232
1,310
3,964
1,380
3,696
1,450
3,425
1,530
3,154
1,610
2,676
1,705
2,198
1,800
3,400
1,450
Latent
Total
BTU/h
Watts
6,024
1,580
6,307
1,675
5,390
1,770
5,635
1,870
4,680
1,970
4,819
2,080
3,757
2,190
3,683
2,385
2,508
2,450
4,068
1,970
Latent
Total
BTU/h
Watts
8,880
1,880
8,486
1,995
8,092
2,110
7,634
2,230
7,176
2,350
6,720
2,490
6,264
2,630
5,479
2,790
4,693
2,950
6,650
2,360
www.goodmanmfg.com
GSZ140191A* + ARUF25B14** + TXV
Conditions: 80 °F IBD, 67 °F IWB @ 614 CFM
Outdoor
Total
Sensible
Tem. ° F.
BTU/h
BTU/h
75
18,650
13,962
80
18,450
14,033
85
18,200
14,103
90
17,800
13,970
95
17,400
13,838
100
16,900
13,650
105
16,450
13,463
110
16,000
13,514
115
15,550
13,564
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
16,800
13,550
GSZ140251A* + ARUF25B14** + TXV
Conditions: 80 °F IBD, 67 °F IWB @ 614 CFM
Outdoor
Total
Sensible
Tem. ° F.
BTU/h
BTU/h
75
24,500
17,976
80
24,200
18,076
85
23,900
18,176
90
23,350
18,015
95
22,850
17,853
100
22,200
17,600
105
21,550
17,347
110
20,950
17,424
115
20,350
17,501
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
22,000
17,450
GSZ140311A* + ARUF29B14** + TXV
Conditions: 80 °F IBD, 67 °F IWB @ 614 CFM
Outdoor
Total
Sensible
Tem. ° F.
BTU/h
BTU/h
75
30,550
22,385
80
30,200
22,492
85
29,850
22,600
90
29,200
22,378
95
28,550
22,156
100
27,750
21,845
105
27,000
21,534
110
26,250
21,596
115
25,550
21,658
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
27,550
21,650
Latent
Total
BTU/h
Watts
4,688
1,250
4,392
1,315
4,097
1,380
3,830
1,450
3,562
1,525
3,275
1,605
2,987
1,685
2,486
1,780
1,986
1,870
3,250
1,525
Latent
Total
BTU/h
Watts
6,524
1,625
6,124
1,720
5,724
1,810
5,360
1,910
4,997
2,010
4,600
2,120
4,203
2,235
3,526
2,365
2,849
2,495
4,550
2,010
Latent
Total
BTU/h
Watts
8,165
1,920
7,708
2,025
7,250
2,130
6,822
2,245
6,394
2,360
5,930
2,485
5,466
2,615
4,679
2,765
3,892
2,915
5,900
2,360
SS-GSZ14