Goodman GPH14H Specifications

Goodman GPH14H Specifications

Gph14h series packaged heat pump up to 14 seer 2 to 5 tons, cooling capacity: 24,000 - 57,000 btu/h & heating capacity: 22,800 - 54,500 btu/h

Advertisement

c
c
:
24,000 - 57,000 Btu/
oolinG
aPacity
H
c
:
22,800 - 54,500 Btu/
eatinG
aPacity
Standard Features
• Energy-efficient compressor with
internal relief valve
• EEM blower motor
• Quiet horizontal discharge
• Copper tube/aluminum fin coil
• Totally enclosed, permanently lubricated
condenser fan motor
• Fully charged system
• Electric heat kit available
as a field-installed option
• AHRI Certified; ETL Listed
Cabinet Features
• Heavy-gauge galvanized-steel cabinet with
attractive Architectural Gray powder-paint finish
• Fully insulated blower compartment
with convenient access panels
• Louvered condenser coil protection
• One footprint; three heights
* Complete warranty details available from your local dealer or at www.
goodmanmfg.com. To receive the 10-Year Parts Limited Warranty,
online registration must be completed within 60 days of installation.
Online registration is not required in California or Québec.
SS-GPH14H
H
H
Contents
Nomenclature .................................................................... 2
Product Specifications ....................................................... 3
Expanded Cooling Data ..................................................... 4
Expanded Heating Data . .................................................. 16
Heat Kit Electrical Data . ................................................... 18
Airflow Data .....................................................................19
Dimensions ......................................................................20
Wiring Diagram . .............................................................. 21
Accessories .......................................................................22
www.goodmanmfg.com
GPH14H
P
H
P
ackaGed
eat
umP
14 SEER
up to
2
5 t
to
ons
2/12
Supersedes 11/11A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GPH14H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Goodman GPH14H

  • Page 1: Table Of Contents

    • Fully insulated blower compartment with convenient access panels • Louvered condenser coil protection • One footprint; three heights * Complete warranty details available from your local dealer or at www. goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-GPH14H ackaGed up to Contents Nomenclature ... 2 Product Specifications ... 3 Expanded Cooling Data ... 4 Expanded Heating Data ..16 Heat Kit Electrical Data ..18 Airflow Data ...19 Dimensions ...20...
  • Page 2: Nomenclature

    2 Tons 42 3½ Tons 2½ tons 48 4 Tons 3 Tons 60 5 Tons www.goodmanmfg.com Engineering Minor Revision Engineering Major Revision Voltage Designator 1 208-230/1/60 3 208-230/3/60 4 460/3/60 Refrigerant 2 R-22 4 R-410A Configuration H Horizontal M Multi-position SS-GPH14H...
  • Page 3: Product Specifications

    ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-GPH14H GPH14 GPH14...
  • Page 4: Expanded Cooling Data

    Pecifications — GPH1424H41a* xPanded oolinG www.goodmanmfg.com SS-GPH14H...
  • Page 5 Pecifications — GPH1424H41a* ( xPanded oolinG cont SS-GPH14H www.goodmanmfg.com...
  • Page 6 Pecifications — GPH1430H41a* xPanded oolinG www.goodmanmfg.com SS-GPH14H...
  • Page 7 Pecifications — GPH1430H41a* ( xPanded oolinG cont SS-GPH14H www.goodmanmfg.com...
  • Page 8 Pecifications — GPH1436H41a* xPanded oolinG www.goodmanmfg.com SS-GPH14H...
  • Page 9 Pecifications — GPH1436H41a* ( xPanded oolinG cont SS-GPH14H www.goodmanmfg.com...
  • Page 10 Pecifications — GPH1442H41a* xPanded oolinG www.goodmanmfg.com SS-GPH14H...
  • Page 11 Pecifications — GPH1442H41a* ( xPanded oolinG cont SS-GPH14H www.goodmanmfg.com...
  • Page 12 Pecifications — GPH1448H41a* xPanded oolinG www.goodmanmfg.com SS-GPH14H...
  • Page 13 Pecifications — GPH1448H41a* ( xPanded oolinG cont SS-GPH14H www.goodmanmfg.com...
  • Page 14 Pecifications — GPH1460H41a* xPanded oolinG www.goodmanmfg.com SS-GPH14H...
  • Page 15 Pecifications — GPH1460H41a* ( xPanded oolinG cont SS-GPH14H www.goodmanmfg.com...
  • Page 16: Expanded Heating Data

    1.84 1.79 1.75 1.70 1.66 1.61 2.36 2.17 1.97 1.77 1.55 1.30 20.8 18.7 16.5 14.4 12.3 10.1 16.1 14.4 12.8 11.1 2.46 2.39 2.33 2.27 2.21 2.15 2.48 2.28 2.08 1.86 1.63 1.37 kW = Total system power SS-GPH14H...
  • Page 17 Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. High pressure is measured at the liquid line access fitting. Amps: Unit amps (comp.+ evaporator motor + condenser fan motor) SS-GPH14H Outdoor Ambient Temperature 36.3 33.8...
  • Page 18: Heat Kit Electrical Data

    9.5 / 32,400 14.25 / 48,600 19.5 / 66,500 4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.5 / 66,500 4.75 / 16,200 7 / 23,800 9.5 / 32,400 14.25 / 48,600 19.5 / 66,500 SS-GPH14H...
  • Page 19: Airflow Data

    Watts GPH14 T2,T3 48H41A* Watts T4, T5 Watts T1, T2,T3 Watts GPH14 60H41A* T4, T5 Watts * Speed set at T2 at factory. SS-GPH14H E.S.P. (In. of H 0.10 0.20 0.30 0.40 1061 1022 1103 1063 1012 1285 1240 1202...
  • Page 20: Dimensions

    34.075” inimal learances  66.25” PeninGs            www.goodmanmfg.com “A” Dimensions Chassis Model Height Size GPH1424 Small 30” GPH1430 GPH1436 Medium 35” GPH1442 GPH1448 Large 38¾” GPH1460   SS-GPH14H...
  • Page 21: Wiring Diagram

    SEE NOTE 4 SEE NOTE 6 SEE NOTE 2 208-240 SEE NOTE 3 Wiring is subject to change. Always ⚠ refer to the wiring diagram or the unit for the most up-to-date wiring. SS-GPH14H SEE NOTE 3 RCCF SEE NOTE 4 CONTROL COMP COMPONENT LEGEND CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER...
  • Page 22: Accessories

    Square to Round for Horizontal Application Item Number Small Chassis Medium/Large Chassis PCE101-103 PCE101-103 PCP101-103 PCP101-103 PCP101-103 R8 PCP101-103 R8 PCEF101-103 PCEF101-103 OT/EHR18-60 OT/EHR18-60 GPGHFR101-103 GPGHFR101-103 PEHH101-103 PEHH101-103 PCMD101-103 PCMD101-103 PCMDH101-103 PCMDH101-103 PCMDM101-103 PCMDM101-103 OT18-60A OT18-60A PCCP101-103 PCCP101-103 SQRPC101 SQRPC102/103 SQRPCH101 SQRPCH102/103 www.goodmanmfg.com SS-GPH14H...
  • Page 23 Pecifications otes SS-GPH14H www.goodmanmfg.com...
  • Page 24 Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2012 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. www.goodmanmfg.com SS-GPH14H...

Table of Contents

Save PDF