Human Sensor (Energy Saving); Filter Clean - Fujitsu ASYG09KXCA Operating Manual

Wall mounted type
Hide thumbs Also See for ASYG09KXCA:
Table of Contents

Advertisement

Human Sensor (Energy Saving)

To prevent waste of electricity, this function controls the temperature
setting when no one is occupying the room. Energy Saving function is
on at the time of purchase.
To activate the Energy Saving function, press the "SENSOR"
1
button.
will be fl ashing on the remote controller display.
To deactivate the Energy Saving function, press the "SENSOR"
2
button again.
will no longer be shown on the remote controller
display.
About the ENERGY SAVING Function
If no one enters the room for approximately 20 minutes, the set
temperature will be automatically controlled.
(When someone comes back into the room, the human sensor will
detect this, and automatically revert to the original settings.)
Operation
mode
(if there is no one in the room for a while)
The set temperature will be increased by a maximum of
COOL/DRY
approximately 2˚C.
The set temperature will be decreased by a maximum
HEAT
of approximately 4˚C.
This runs the ENERGY SAVING function automatically
AUTO
for the selected mode (Cooling/ Heating).
● When using together with the SLEEP timer (page 7), the SLEEP
timer will be prioritized.
● During 10°C HEAT operation, if there is no one in the room the
set temperature will not be changed.
● Application range is as follows.
Vertical angle 90° (Side view)
7 m
90°
Energy Saving function may not work when the room temperature is
very different from the temperature defi ned in temperature setting, such
as when immediately after starting the operation.
* The horizontal angle can be changed according to the installation
position. For more information, refer to installation manual.
About the HUMAN SENSOR
Details about detection with the human sensor
The human sensor detects whether there are people in the room
by looking for movement by people in the room.
Notice
Since the human sensor detects infrared light given out by
people, there may be cases where this detection is incorrect.
Situations in which the sensor will detect no people in the
room, even when there is someone there
When the temperature is high and the difference with be-
tween people's body temperature is small.
(Such as during the summer when the temperature is 30°C
or higher.)
When there is someone in the room, but they do not move
for a long period of time.
When someone is hidden behind a sofa, other furniture,
glass, or in similar situations.
When someone is wearing extremely thick clothing and has
their back facing the sensor.
Situations in which the sensor will incorrectly detect people
in the room, even when there is no one there
When there is a dog or a cat moving around in the room.
When the wind is making curtains or plants move.
When there are heating units, humidifi ers, or electric appli-
ances such as oscillating electric fans operating.
Operating details
Horizontal angle* 100° (Top view)
7 m
50°
50°
AIR CONDITIONER Wall Mounted Type

Filter Clean

When the air conditioner operation time reaches a total of 40 hours,
the air fi lter is automatically cleaned while the operation is paused.
Accumulated dust is automatically cleaned and collected in the dust
box.
Notice
The fi lter cleaning time is approximately 13 minutes. The indoor
unit "FILTER CLEAN" indicator lights up during fi lter cleaning.
If the air conditioner is used continuously without stopping, opera-
tion is always stopped temporarily after 64 hours have elapsed for
one fi lter cleaning operation. (Operation restarts after fi lter cleaning
is complete.)
If the "FILTER CLEAN" indicator blinks slowly, this indicates that it
is time to clean the dust box. (After approximately 10,000 hours of
air conditioner operation have elapsed.) Filter cleaning is not car-
ried out at this time. Please clean the dust box.
Filter cleaning does not work when the indoor unit is paused with
the SLEEP timer. If the indoor unit is paused every time with the
SLEEP timer, while it depends on the amount of dust, it is recom-
mended to carry out fi lter cleaning with the remote control approxi-
mately once a week.
The fi lter clean function can be disabled. Consult authorized service
personnel to disable fi lter clean function.
• If the fi lter clean has been disabled, perform a fi lter clean regularly
using the remote controller.
Please do not touch the dust box or air fi lter during fi lter clean-
ing. Removing the dust box / air fi lter or pulling or pushing up
the air fi lter with your hand may damage the indoor unit.
To clean the fi lter immediately
Press the "FILTER CLEAN" button while the air conditioner is not
1
operating.
The indoor unit "FILTER CLEAN" indicator lights up.
To stop fi lter cleaning, press the "FILTER CLEAN" button.
2
The indoor unit "FILTER CLEAN" indicator switches off.
Notes:
• Do not disconnect the power supply or turn off the breaker during
fi lter cleaning until the "FILTER CLEAN" indicator switches off.
Doing so may damage the indoor unit.
• Depending on how dirty the air fi lter is, dust may not be completely
removed with one fi lter cleaning. In this case, please activate fi lter
cleaning again with the remote control.
• In order to prevent damage to the device, fi lter cleaning may not
operate if it is activated repeatedly with the remote control. Please
wait approximately 30 minutes before activating fi lter cleaning.
• The fi lter may not be able to remove dust, or may not operate
correctly depending on the type of dust, such as dust with a large
amount of cigarette tar or oil, or if the dust has hardened. In this
case, please clean the dust box and air fi lter.
• Dust may accumulate inside if the indoor unit is used in an
environment with very fi ne dust or a large amount of oil. It is
recommended to carry out inspection maintenance in addition to
regular cleaning.
• If fi lter cleaning is stopped during operation, it will not stop
immediately since it will only stop after the air fi lter has returned to
its original position.
• The operation time that needs to be reached for automatically
cleaning the air fi lter can be changed, and the "FILTER CLEAN"
indicator can be set so that it does not turn on. For more information,
consult authorized service personnel.
CAUTION
OPERATING MANUAL
En-8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asyg12kxca

Table of Contents