1. Specifications Wall mounted Type Inverter heat pump Model name ASYG09KXCA ASYG12KXCA Power supply 230 V ~ 50 Hz Available voltage range 198—264 V 2.50 3.40 Rated Btu/h 8,500 11,600 Cooling 0.6—3.5 0.6—5.3 Min.—Max. Btu/h 2,000—11,900 2,000—18,000 Capacity 3.60 5.00...
Page 7
Wall mounted Type Inverter heat pump Model name ASYG09KXCA ASYG12KXCA NOTES: • Specifications are based on the following conditions: – Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB. – Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
Page 8
Model name ASYG09KXCA ASYG12KXCA Cooling Energy efficiency class Heating (Average) Cooling 2.5 (35 °C) 3.4 (35 °C) Pdesign Heating (Average) 3.4 (-10 °C) 3.5 (-10 °C) SEER Cooling kWh/kWh SCOP Heating (Average) Annual energy consumption kWh/a QHE (Average) Cooling Sound power level...
After installation of mobile app, user registration is required. For user registration and setup infor- mation, refer to Setting Manual attached with the product. For the latest version of the Wireless LAN (WLAN) control manuals, refer to the following web site. https://www.fujitsu-general.com/global/support/ - 5 - 2-1. System requirement...
2-2. Wireless LAN function list Attached wireless Item Mobile app remote controller Operation on/off ○ ○ Operation mode setting ○ ○ Set temperature setting ○ ○ Fan speed setting ○ ○ Louver position adjustment (vertical/ ○ ○ Airflow direction horizontal) Air conditioning setting Swing (vertical/horizontal)
3. Dimensions 3-1. Models: ASYG09KXCA and ASYG12KXCA Unit: mm Outline of unit 292.5 100.5 - 7 - 3-1. Models: ASYG09KXCA and ASYG12KXCA 3. Dimensions...
Page 12
NOTE: Dual side fans rotate downward when the unit is operating as shown in the figure above. If the depth of the obstruction is larger than 95 mm, secure specified distance* in between the indoor unit and the obstruction. - 8 - 3-1. Models: ASYG09KXCA and ASYG12KXCA 3. Dimensions...
4. Wiring diagrams 4-1. Models: ASYG09KXCA and ASYG12KXCA ¢ Main PC board ¢ Sub PC board - 9 - 4-1. Models: ASYG09KXCA and ASYG12KXCA 4. Wiring diagrams...
Airflow Rate (AFR): For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP) For heating capacity: Total Capacity (TC) and Input Power (IP) 5-1. Cooling capacity ¢ Model: ASYG09KXCA Indoor temperature °CDB °CWB °CDB...
6. Fan performance 6-1. Air velocity distributions ¢ Models: ASYG09KXCA and ASYG12KXCA Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Unit: m/s Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Left &...
6-2. Airflow ¢ Models: ASYG09KXCA and ASYG12KXCA Cooling Fan speed Airflow HIGH QUIET Heating Fan speed Airflow HIGH QUIET - 13 - 6-2. Airflow 6. Fan performance...
8. Safety devices Model Type of Protection form protection ASYG09KXCA ASYG12KXCA Circuit protection Current fuse (PCB*) 250 V, 4 A 150 ±15 °C Activate Fan motor stop Fan motor Power IC thermal protection shutdown protection 120 ±15 °C Reset Fan motor restart...
10. Function settings To adjust the functions of this product according to the installation environment, various types of function settings are available. NOTE: Incorrect settings can cause a product malfunction. 10-1. Function settings by using remote controller Some function settings can be changed on the remote controller. After confirming the setting proce- dure and the content of each function setting, select appropriate functions for your installation envi- ronment.
Page 25
¢ Contents of function setting Each function setting listed in this section is adjustable in accordance with the installation environ- ment. NOTE: Setting will not be changed if invalid numbers or setting values are selected. Function setting list Function no. Functions Filter clean operation interval Left/right swing operation range...
Page 26
3) Room temperature control for indoor unit sensor Depending on the installed environment, correction of the room temperature sensor may be re- quired. Select the appropriate control setting according to the installed environment. The temperature correction values show the difference from the Standard setting "00" (manufactur- er’s recommended value).
Page 27
6) Indoor unit fan control for energy saving for cooling Enables or disables the power-saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation. Function number Setting value Setting description Factory setting Disable Enable Remote controller...
10-2. Custom code setting for wireless remote controller To interconnect the air conditioner and the wireless remote controller, assignment of the custom code for the wireless remote controller is required. NOTE: Air conditioner cannot receive a signal if the air conditioner has not been set for the custom code.
10-3. Switching the temperature unit of remote controller Displayed temperature unit on the remote controller LCD can be switched between °C (Celsius) and °F (Fahrenheit). To change temperature unit, do as follows: Press the TEMP. (Up) button ( ) for at least 5 seconds to display the current temperature unit. (Factory setting: °C) Press the TEMP.
1. Specifications Type Inverter heat pump Model name AOYG09KXCA AOYG12KXCA Power supply 230 V ~ 50 Hz Available voltage range 198—264 V Starting current Cooling 1,975 2,230 Airflow rate Heating 1,820 1,975 Type × Q'ty Propeller fan × 1 Motor output Cooling Sound pressure level *1 dB (A)
3. Installation space 3-1. Models: AOYG09KXCA and AOYG12KXCA ¢ Space requirement Provide sufficient installation space for product safety. Single outdoor unit installation • When the upper space is open: Unit: mm When there are obstacles at the rear only. When there are obstacles at the rear and sides.
Page 35
Multiple outdoor unit installation • When the upper space is open: Unit: mm When there are obstacles at the rear only. When there are obstacles at the front only. 1,000 or more or more When there are obstacles at the front and rear.
Page 36
Outdoor unit installation in multi-row Unit: mm Single parallel unit arrangement Multiple parallel unit arrangement 100 or more 200 or more 1,000 or more 2,000 or more 200 or more 400 or more 1,000 or more 500 or more 200 or more NOTES: •...
6. Capacity compensation rate for pipe length and height difference Height difference H Indoor unit is higher than outdoor unit Indoor unit is lower than outdoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Connection pipe Connection pipe 6-1. Models: AOYG09KXCA and AOYG12KXCA NOTE: Values mentioned in the table are calculated based on the maximum capacity.
7. Additional charge calculation 7-1. Models: AOYG09KXCA and AOYG12KXCA Refrigerant type Refrigerant amount 1,300 ¢ Refrigerant charge Total pipe length 7.5 or less 15 (Max.) 0 g/m Additional charge NOTE: There is no additional refrigerant charge in this product. (Chargeless system) - 36 - 7-1.
9-2. Sound level check point Rear Microphone Microphone Airflow Side view Rear view NOTE: Detailed shape of the actual outdoor unit might be slightly different from the one illustrated above. - 39 - 9-2. Sound level check point 9. Operation noise (sound pressure)
10. Electrical characteristics Model name AOYG09KXCA AOYG12KXCA Voltage 230 ~ Power supply Frequency Max operating current *1 14.0 16.0 Starting current Circuit breaker current Power cable Wiring spec. *2 Connection cable *3 Limited wiring length *1: Maximum operating current is the total current of the indoor unit and the outdoor unit. *2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.
11. Safety devices Model Type of protection Protection form AOYG09KXCA AOYG12KXCA 250 V, 25 A 250 V, 5 A Circuit protection Current fuse (Main PCB) 250 V, 3.15 A 125 ±10 °C Activate Fan motor stop Fan motor Thermal protection protection program 120 ±10 °C...