Timer Operation

Note for timer settings:
Any interruption of the power supply, such as a blackout or cutting off
of a circuit breaker, makes the set internal clock go wrong.
In such a case, the "TIMER" indicator on the indoor unit blinks, and
you need to readjust the setting.
ON timer or OFF timer
Turn on the indoor unit by pressing the "Start/Stop(
1
"OPERATION" indicator on the indoor unit turns on.
If the indoor unit is already operating, skip this step.
Press the "ON" timer button or the "OFF" timer button.
2
Clock indicator on the remote controller is displayed, and "TIMER"
indicator on the indoor unit turns on.
Adjust the time by pressing the "SELECT" button.
3
remote controller blinks and the signal is being transmitted.
(About 5 seconds later, the remote controller display returns to
standby screen.)
To cancel the timer and return to the normal operation, press the "Timer
CANCEL" button.
To redo the timer setting, perform step 2 and 3.
Program timer (combined use of the ON timer and the OFF timer)
You can set an integrated ON–OFF or OFF–ON timer.
Either of the timer whose confi gured starting time is closer to the
current time works fi rst, and the order of timer operation is displayed
as follows:
Timer
ON–OFF timer
OFF–ON timer
The timer that is set later starts counting down after the counting
down of the preceding timer is fi nished.
Notes:
• If you change the setting value for the timer after the program timer
is set, the counting down of the timer will be reset at that moment.
• Time setting for each combination should be within a span of 24 hours.
SLEEP timer
Press the "SLEEP timer" button to activate the SLEEP timer.
1
"OPERATION" indicator and "TIMER" indicator on the indoor unit
turns on.
Adjust the time by pressing the "SELECT" button.
2
remote controller blinks and the signal is being transmitted.
(About 5 seconds later, the remote controller display returns to
standby screen.)
Each time you press the button, the time changes as follows:
0H
1H
30M
00M
(30 min.)
To repeat the timer, press the "SLEEP timer" button when
indicator is not displayed on the remote controller display.
To help you to fall asleep comfortably and prevent excessive warming
or cooling in sleep, the SLEEP timer controls the temperature setting
automatically in accordance with the set time shown as follows. The
air conditioner completely turns off after the set time has elapsed.
In HEAT mode
1 °C 2 °C 3 °C 4 °C
30 min.
1 hour
1.5 hour
Set time
OPERATING MANUAL
En-7
Indicator on remote controller display
2H
3H
5H
7H
00M
00M
00M
00M
In COOL or DRY mode
Set time
Set
temperature
1 hour
1 °C

Dual Fan Comfort

* Dual fan is OFF at the time of purchase.
To activate the dual fan comfort, press the "DUAL FAN
1
COMFORT" button.
To deactivate the dual fan comfort, press the "DUAL FAN
2
COMFORT" button again.
display.
)" button.
Notes:
• Dual fan operates with recommended settings.
• Operation only with dual fan is not possible.
• In HEAT mode, there is no dual fan airfl ow with the following.
- When the room temperature is lower than the set temperature
- When the temperature of HEAT airfl ow is low
- During automatic defrosting operation
on the
• There is more airfl ow when dual fan is ON compared to when it is
OFF, so the operating noise is also louder.
<Additional setting>
Dual fan settings might not match your preferred settings when in COOL
mode, DRY mode or FAN mode.
In this case, use the remote control to change the dual fan airfl ow
direction so the airfl ows further.
1. Turn off the indoor unit by pressing the
"Start/Stop(
2. Press the "DUAL FAN COMFORT" button
for at least 5 seconds until the current
"DUAL FAN" status is displayed.
3. Press the "TEMP." buttons (  /  ) to switch
the setting.
"1"(Standard) "2"(Far)
4. Press the "Start/Stop(
unit. After the status is sent, the display will automatically return to
the original screen.
If no buttons are pressed within 30 seconds after the "DUAL FAN"
status is displayed, the system returns to the original clock display. In
this case, start again from step 1.
If this still does not match your preferences, consult authorized service
personnel. (Dual fan settings can be adjusted more precisely.)
on the
9H
00M
hours
2 °C
will be fl ashing on the remote controller display.
will no longer be shown on the remote controller
)" button.
)" button to send the setting to the indoor