7-13. Human sensor for energy saving

If no one enters the room for approximately 20 minutes, the set temperature is automatically con-
trolled. (→hen someone comes back into the room, the human sensor detect this, and automatically
revert to the original settings.)
Operation mode
Cool/Dry
Heat
Auto
• Application range:
Energy saving function may not work when the room temperature is very different from the tem-
perature defined in the temperature setting, such as when immediately after starting the operation.
• Details about detection with the human sensor:
The human sensor detects whether there are people in the room by looking for movement by peo-
ple in the room.

7-14. Outdoor unit low noise operation

The outdoor unit low noise operation functions by OUTDOOR UNIT LO→ NOISE button on the re-
mote controller.
This operation stops the PFC control, and changes the current value.
Operation mode
Cooling/Dry mode
Heating mode
7-13. Human sensor for energy saving
(If there is no one in the room for a while)
The setting temperature is increased by maximum 2°C.
(Maximum setting temperature: 30°C)
The setting temperature is decreased by maximum 4°C.
(Minimum setting temperature: 16°C)
Energy saving function is performed automatically for the selected mode
Vertical angle
90°
6 m
90
°
Side view
- (04-29) -
Operation details
(cool/heat/dry).
Horizontal angle
6 m
50
50
°
Top view
Current
Trigger condition
1.9 A
100°
°
Release condition
1.4 A
7. Various control