IDEC WB2F User Manual page 28

Support tool. 2d code scanner
Hide thumbs Also See for WB2F:
Table of Contents

Advertisement

No.
Name
12
SnapShot
*1
13
Read
14
Draw (Bitmap)
15
Draw (JPEG)
16
Save Image
Success rate
17
measurement
Decoding Time
18
measurement
Symbol position
19
measurement
20
Stop reading
21
Communication monitor
22
ASCII
23
HEX
24
Clear
25
Enable setting changes
Reading parameter table
26
setting
27
Receive
28
Send
29
Save
30
Load
31
Close
*1 Note that even when "Symbol Reading Setting" > "Symbol reading" is set to "Multi read sequential
output" or "Multi read batch output" in the Scanner settings screen, "Single read" operation will take
place.
28 / 35
WB2F Support Tool User's Manual
Performs only Image Capture using the reading parameter table selected
in Specifying tables (No. 7).
Performs Image Capture + Decode using the reading parameter table
selected in Specifying tables (No. 7).
Acquires image data captured with SnapShot (No. 12) or Read (No. 13) in
bitmap format. Drawing is not performed.
Acquires image data captured with SnapShot (No. 12) or Read (No. 13) in
bitmap format. Drawing is not performed.
Saves an image acquired with Draw (Bitmap) (No. 14) or Draw (JPEG)
(No.15) to your computer.
Measures the read rate using the reading parameter table selected in
Specifying tables (No. 7). During measurement, only Stop reading (No.
20) is valid.
Measures the decoding time using the reading parameter table selected in
Specifying tables (No. 7). During measurement, only Stop reading (No.
20) is valid.
Measures the symbol position using the reading parameter table selected
in Specifying tables (No. 7). During measurement, only Stop reading
(No. 20) is valid.
Stops reading.
Displays communication requests and responses.
Blue text: request, Red text: response.
Sets the Communication monitor (No. 21) to the ASCII display mode.
Sets the Communication monitor (No. 21) to the hexadecimal display
mode.
Clears the Communication monitor (No. 21).
Select the checkbox to enable changes to Reading parameter table
setting (No. 26). While the checkbox is selected, only the image
monitor/console screen can be used.
You can change the settings of the reading parameter table selected in
Specifying tables (No. 7).
Shows the settings of the reading parameter table selected in Specifying
tables (No. 7) in Reading parameter table setting (No. 26).
Applies settings changed in Reading parameter table setting (No. 26) to
the table selected in Specifying tables (No. 7). Execute Receive (No. 27)
to enable.
Saves the setting values to the setting value region (non-volatile).
Loads the setting values from the setting value region (non-volatile).
Close the image monitor screen.
WB2F-SOFT-SUPPORT-TOOL-MANUAL-E
Description
B-1956(0)

Advertisement

Table of Contents
loading

Table of Contents