INSTALLATION OF WINDOW KIT
Partially open the window and then fix the window kit to the window horizontally or vertically.
Keep at least 50 cm from any objects and the air inlets grills on the side of the unit.
Clip the other end of the hose with the fishtail adapter to the air outlet of the window slider.
Make sure the unit is upright and there are no obstructions to the air inlet and outlet grills.
The window kit is only designed to be installed with sliding or sash windows and doors. The
window kit is not made to be used with any other style of window. However the fish tail
adaptor can be used without the slide bar on most windows and doors, but without sealing
the rest of the window opening the efficiency of the unit will be reduced. When using cooling
mode ensure that the opening left is as small as possible. The best form of installation is
through a wall duct.
Please note that the unit will still need to be vented in heating mode, ideally through the wall.
By properly venting, your air conditioner expels cold air from your room while efficiently
heating it without leaving cold air coming back.
Note: Avoid bending the air hose more than 30 degrees!
IMPORTANT SAFEGUARDS
The soft hose will extend from 28 cm to 150 cm, and the unit will support hoses of upto
300cm. If hose is extended above this length the unit may malfunction and this can
invalidate the warranty. The shorter the hose the better the results; ideally for best
performance, do not extend the hose by more than 40 cm. The outlet vent must be well
ventilated and not obstructed as this will cause the unit to overheat.